Laserfiche WebLink
<br />FORM 400C-Q1 <br /> <br />CLIMATE ZONES 4 .5 6 <br /> <br />HVAC, GLASS AREA, AND LIGHTING: See Chart below. Select and circle the desired combination of glass-to-wall area percentage (GL AREA %) and <br />lighting level (W/SF) based on the type of HVAC system and efficiency. Report the levels installed on the front of the form. <br /> <br />Table 4C-8 OFFICE BUILDING < 5,000 SF <br /> MAXIMUM ALLOWABLE GLASS AREA % AND ALLOWABLE LIGHTING W/SF <br /> Cooling Equipment Capacity ~5,OOO BtuJh, Room Units, PTACs Capacity <65,000 Btulh <br />EER: 8.9-9,0 EER: 9.1-10.0 EER: 10.1-11.0 EER: 11.1-UP SEER: 10.o-UP <br />GL AREA LIGHTING GL AREA LIGHTING GL AREA LIGHTING GL AREA LIGHTING GL AREA LIGHTING <br />% W/SF % W/SF % W/SF % W/SF % W/SF <br />20 2.4 20 2.6 30 2.6 25 2.8 25 2.8 <br />25 2.2 30 2.4 40 2.4 35 2.6 35 2.6 <br /> 35 2.2 45 2.2 45 2.4 45 2.4 <br />Glazing: 50 2.2 50 2.2 <br />Solar Heat Gain Coefficient <=0.61 And Heat Pump And Heat Pump <br /> COP: > = 3.0 HPSF: > = 6.8 <br /> 75 2.2 75 2.2 <br /> <br />Table 4C-9 SCHOOL BUILDING < 5,000 SF <br /> MAXIMUM ALLOWABLE GLASS AREA % AND ALLOWABLE LIGHTING W/SF <br /> Cooling Equipment Capacity ~5,000 Btu/h, Room Units, PT ACs Capacity <65,000 Btu/h <br />EER: 8.9-9.0 EER: 9.1-10.0 EER: 10.1-11.0 EER: 11.1-UP SEER: 10.o-UP <br />GLAREA LIGHTING GL AREA I LIGHTING GL AREA LIGHTING GL AREA LIGHTING GL AREA LIGHTING <br />% W/SF % W/SF % W/SF % W/SF % W/SF <br />20 2.0 I 20 I 2.2 I 20 2.4 20 2.6 20 2.6 <br />25 1.8 25 2.0 25 2.2 25 2.4 25 2.4 <br /> 30 1.8 30 2.0 30 2.2 30 2.2 <br />Glazing: 35 1.8 35 2.0 35 2.0 <br />Solar Heat Gain Coefficient <=0.87 40 1.8 40 1.8 <br /> And Heat Pump And Heat Pump <br /> COP: > = 3.0 HPSF: > = 6.8 <br /> 60 2.6 60 2.6 <br /> <br />Table 4C-10 <br /> <br />STORAGE BUILDING < 5,000 SF <br /> <br />MAXIMUM ALLOWABLE GLASS AREA 01. AND ALLOWABLE LIGHTING W/SF <br /> <br />Cooling Equipment Capacity ~5,000 Btu/h, Room Units, PT ACs <br /> <br />EER: 8.9-9.0 EER: 9.1-10.0 EER: 10.1-11.0 <br />GL AREA LIGHTING GL AREA I LIGHTING GL AREA LIGHTING <br />% W/SF % W/SF % W/SF <br />5 1.0 I 5 I 1.101 5 1.25 <br />15 0.50 15 0.75 <br />I 25 0.50 <br /> <br />EER: 11.1-UP <br />GL AREA LIGHTING <br />% W/SF <br />5 1.25 <br />15 0.87 <br />25 0.75 <br />And Heat Pump <br />COP: > = 3.0 <br />40 1.25 <br /> <br />Capacity <65,000 Btu/h <br />SEER: 10.o-UP <br />GL AREA LIGHTING <br />% W/SF <br />5 1.25 <br />15 0.87 <br />25 0.75 <br />And Heat Pump <br />HPSF: > = 6.8 <br />40 1.25 <br /> <br />Glazing: <br />Solar Heat Gain Coefficient <=0.77 Q[ <br />Insulated <br /> <br />-4- <br />