<br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> CHAPTER 4 - Commercial Building Compliance Methods <br />FORM 400C-01 CENTRAL <br />Limited and Special Use Buildings Climate Zones 4 5 6 <br />Project Name: Zone: <br />Address: Building Classification: <br />City, Zip Code: Building Permit No.: <br />Builder: Permitting Office: <br />Owner: Jurisdiction No.: <br /> <br />... <br /> <br /> BUILDING INFORMATION <br />WALLS ROOF/CEILING FLOORS DOORS GLASS <br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA <br />Concrete ICBS) lU ),'\' II Under Attic ' ~tt. ~ac Slab-on-orade EJ 1 .r;;;; on Wood Sinale wall 1.IIi( I .({('(". '7 <br />Wood frame Sinale Assemblv Raised Wood Metal Double wall <br />Metal frame Other: Raised Concrete Insulated ~U(l II!. 1.. Sinnle roof <br />Insulation R-value [ot'" Insulation R-value 1;1: Insulation R-value Other Double, roof <br /> <br /> SYSTEMS INFORMATION <br /> AIR CONDITIONER HEATING SYSTEM HOT WATER <br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUIH TYPE <br />L'nitary & Heat Pump Central & Heat Pump Electric <br /><65,000 Btulh 1L- SEER -8- <65,000 Btuth _ HSPF Vir..::c (; Resistance 0 <br /><:65,000 Btulh _EER _'PLV - <:65,000 Btuth -L COP Dedicated Heat Pump 0 <br />Water cooled _EER _'PLV - Water cooled _COP - Gas <br />Evaporatively cooled _EER - Evaporatively cooled _COP - Natural 0 <br />PTAC _EER - Electric Resistance _COP - LPG 0 <br />Chiller _COP _IPLV - Gas/Oil (circle one) HRU 0 <br />Gas heat pump _COP - <225,000/300,000 Btuth _ AFUE - Other: 0 <br />Other: <:225,0001300,000 Btulh Et <br />LIGHTING Total Lighting Wattage Jf J.f () 0 ,~ 1 SIZING CALCULATION I DUCTS R-value {;, <br /> - - 0 t.t J/~v <br />Total Conditioned Floor Area t;7j 0 V Watts/sq. ft. Attached Location <br /> <br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.) <br />Comoonents Section Reauirements Check <br />Ooerations Manual 102.1 Ooerations manual will be orovided to owner. ~ <br />Windows & Doors 406.1 Maximum: .3 elm oer sa.ft. of window area; Maximum: 1.2 elm oer so.ft. of door area. 'Jt: <br />Joints/Cracks 406.1 To be caulked, aasketed, weatherstriODed or otherwise sealed. ....r <br />Droooed Ceilina Cavity 406.1 Vented: seal and insulate ceilina (no T-bar ceilinas). Unvented, no ceilina air barrier: seal and insulate roof and side walls. X <br />Reheat 407.1 Electric resistance reheat prohibited. ,~ J4 <br />Ventilation 409.1 Supolied with readily accessible switch for shut-off anellor volume reduction when ventilation is not required. .", <br />HVAC Efficiency 407.1,40S.1 Minimum efficiencies - Heatina: Tables 4-7, 4-S, 4-9. Cooling': Tables 4-3, 4-4, 4-5, 4-6. ie' <br />HVAC Controls 407.1 Separate readiiVaccessible manual or automatic thermostat for each svstem. , <br />HVAC Ducts 410.1 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated <br /> and installed in accordance with the criteria of section 410.1. ;< <br />Balancing 410.1 HVAC distribution system(s) tested and balanced. ,;, <br />Piping Insulation 411.1 In accordance with Table 4-11. ,. <br />Water Heaters 412.1 Automatic electric storage water heaters ~120 gallons and gas & oil fired storage water heaters S75,OOO Btuth shall meet <br /> performance requirements in Table 4-12. Electric >120 gallons: standby loss ~.30+27NT. Gas >75,000, Oil> 105,000: Et .78, Y. <br /> Standby loss ~ 1.30+114NT. Gas, Oil >155,000: E,.7S, Standby loss ~ 1.30+95NT. <br />Swimming Pools 412.1 Spas & heated pools must have covers. Non-commercial pools must have pump timer. Gas spa & pool heaters must li/ fJ <br />& Spas have a minimum thermal efficiency of 7S%. <br />Hot Water Pipe 412.1 Piping heat loss is limited to the levels in Table 4-11 for circulating systems and the first S' of pipe from a storage ~/r-) <br />Insulation tank. <br />Water Fixtures 412.1 Shower head water flow restricted to maximum of 2.5 gpm at SO psi. Toilets meet 42CFR 6295(k). Public lavatory fixture ~ <br /> maximum flow of .5 gpm; or if self-closing valve, .25 gallon circulating, .5 gallon non-circulating. <br />Lighting 415.1 Ballasts shall have Power Factors no less than .90. <br /> <br />If required by Florida law, I hereby certify that the system design is in compliance with the Florida Energy Code. Registration No. <br />ARCHITECT: <br />ELECTRICAL SYSTEM DESIGNER: <br />LIGHTING SYSTEM DESIGNER: <br />MECHANICAL SYSTEM DESIGNER: <br />PLUMBING SYSTEM DESIGNER: <br />Compliance with Chapter 4 was demonstrated by a Prescriptive Measures methodology: <br />Detached Buildings <200 sq.ft. 0 Convenience stores <5,000 sq.ft. 0 Office buildings <5,000 sq.ft. Ikl <br />Skyboxes/sports stadiums 0 Restaurants <5,000 sq.ft. 0 SchOOl buildings <5,000 sq.ft. 0 <br />Traffic safety control towers 0 Retail stores <5,000 sq.ft. 0 Storage buildings <5,000 sq.ft. 0 <br />I hereby certify that the/plans and ,specifications covered by ,e calculation are in compliance with the Review of plans and specifications covered by this calculation indicates compliance with <br />Florida Energy Code. fA;/ / .- ._ the Florida Energy Code. Before construction is completed, this building will be inspected <br />PREPARED BY: -----L..~ f1.llo---eJ ~ ~ DATE: ~ ') - (i Y for compliance in accordance wnh Section 553.908, F .5. I <br />I hereby certify that this building is compliance with the Florida Energy Code. BUILDING OFFICIAL: <br />OWNER AGENT: DATE: DATE: <br /> I <br />