<br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br /> CHAPTER 4 - Commercial Building Compliance Methods
<br />FORM 400C-01 CENTRAL
<br />Limited and Special Use Buildings Climate Zones 4 5 6
<br />Project Name: Zone:
<br />Address: Building Classification:
<br />City, Zip Code: Building Permit No.:
<br />Builder: Permitting Office:
<br />Owner: Jurisdiction No.:
<br />
<br />...
<br />
<br /> BUILDING INFORMATION
<br />WALLS ROOF/CEILING FLOORS DOORS GLASS
<br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA
<br />Concrete ICBS) lU ),'\' II Under Attic ' ~tt. ~ac Slab-on-orade EJ 1 .r;;;; on Wood Sinale wall 1.IIi( I .({('(". '7
<br />Wood frame Sinale Assemblv Raised Wood Metal Double wall
<br />Metal frame Other: Raised Concrete Insulated ~U(l II!. 1.. Sinnle roof
<br />Insulation R-value [ot'" Insulation R-value 1;1: Insulation R-value Other Double, roof
<br />
<br /> SYSTEMS INFORMATION
<br /> AIR CONDITIONER HEATING SYSTEM HOT WATER
<br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUIH TYPE
<br />L'nitary & Heat Pump Central & Heat Pump Electric
<br /><65,000 Btulh 1L- SEER -8- <65,000 Btuth _ HSPF Vir..::c (; Resistance 0
<br /><:65,000 Btulh _EER _'PLV - <:65,000 Btuth -L COP Dedicated Heat Pump 0
<br />Water cooled _EER _'PLV - Water cooled _COP - Gas
<br />Evaporatively cooled _EER - Evaporatively cooled _COP - Natural 0
<br />PTAC _EER - Electric Resistance _COP - LPG 0
<br />Chiller _COP _IPLV - Gas/Oil (circle one) HRU 0
<br />Gas heat pump _COP - <225,000/300,000 Btuth _ AFUE - Other: 0
<br />Other: <:225,0001300,000 Btulh Et
<br />LIGHTING Total Lighting Wattage Jf J.f () 0 ,~ 1 SIZING CALCULATION I DUCTS R-value {;,
<br /> - - 0 t.t J/~v
<br />Total Conditioned Floor Area t;7j 0 V Watts/sq. ft. Attached Location
<br />
<br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.)
<br />Comoonents Section Reauirements Check
<br />Ooerations Manual 102.1 Ooerations manual will be orovided to owner. ~
<br />Windows & Doors 406.1 Maximum: .3 elm oer sa.ft. of window area; Maximum: 1.2 elm oer so.ft. of door area. 'Jt:
<br />Joints/Cracks 406.1 To be caulked, aasketed, weatherstriODed or otherwise sealed. ....r
<br />Droooed Ceilina Cavity 406.1 Vented: seal and insulate ceilina (no T-bar ceilinas). Unvented, no ceilina air barrier: seal and insulate roof and side walls. X
<br />Reheat 407.1 Electric resistance reheat prohibited. ,~ J4
<br />Ventilation 409.1 Supolied with readily accessible switch for shut-off anellor volume reduction when ventilation is not required. .",
<br />HVAC Efficiency 407.1,40S.1 Minimum efficiencies - Heatina: Tables 4-7, 4-S, 4-9. Cooling': Tables 4-3, 4-4, 4-5, 4-6. ie'
<br />HVAC Controls 407.1 Separate readiiVaccessible manual or automatic thermostat for each svstem. ,
<br />HVAC Ducts 410.1 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated
<br /> and installed in accordance with the criteria of section 410.1. ;<
<br />Balancing 410.1 HVAC distribution system(s) tested and balanced. ,;,
<br />Piping Insulation 411.1 In accordance with Table 4-11. ,.
<br />Water Heaters 412.1 Automatic electric storage water heaters ~120 gallons and gas & oil fired storage water heaters S75,OOO Btuth shall meet
<br /> performance requirements in Table 4-12. Electric >120 gallons: standby loss ~.30+27NT. Gas >75,000, Oil> 105,000: Et .78, Y.
<br /> Standby loss ~ 1.30+114NT. Gas, Oil >155,000: E,.7S, Standby loss ~ 1.30+95NT.
<br />Swimming Pools 412.1 Spas & heated pools must have covers. Non-commercial pools must have pump timer. Gas spa & pool heaters must li/ fJ
<br />& Spas have a minimum thermal efficiency of 7S%.
<br />Hot Water Pipe 412.1 Piping heat loss is limited to the levels in Table 4-11 for circulating systems and the first S' of pipe from a storage ~/r-)
<br />Insulation tank.
<br />Water Fixtures 412.1 Shower head water flow restricted to maximum of 2.5 gpm at SO psi. Toilets meet 42CFR 6295(k). Public lavatory fixture ~
<br /> maximum flow of .5 gpm; or if self-closing valve, .25 gallon circulating, .5 gallon non-circulating.
<br />Lighting 415.1 Ballasts shall have Power Factors no less than .90.
<br />
<br />If required by Florida law, I hereby certify that the system design is in compliance with the Florida Energy Code. Registration No.
<br />ARCHITECT:
<br />ELECTRICAL SYSTEM DESIGNER:
<br />LIGHTING SYSTEM DESIGNER:
<br />MECHANICAL SYSTEM DESIGNER:
<br />PLUMBING SYSTEM DESIGNER:
<br />Compliance with Chapter 4 was demonstrated by a Prescriptive Measures methodology:
<br />Detached Buildings <200 sq.ft. 0 Convenience stores <5,000 sq.ft. 0 Office buildings <5,000 sq.ft. Ikl
<br />Skyboxes/sports stadiums 0 Restaurants <5,000 sq.ft. 0 SchOOl buildings <5,000 sq.ft. 0
<br />Traffic safety control towers 0 Retail stores <5,000 sq.ft. 0 Storage buildings <5,000 sq.ft. 0
<br />I hereby certify that the/plans and ,specifications covered by ,e calculation are in compliance with the Review of plans and specifications covered by this calculation indicates compliance with
<br />Florida Energy Code. fA;/ / .- ._ the Florida Energy Code. Before construction is completed, this building will be inspected
<br />PREPARED BY: -----L..~ f1.llo---eJ ~ ~ DATE: ~ ') - (i Y for compliance in accordance wnh Section 553.908, F .5. I
<br />I hereby certify that this building is compliance with the Florida Energy Code. BUILDING OFFICIAL:
<br />OWNER AGENT: DATE: DATE: