<br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br /> CHAPTER 4 - Commercial Building Compliance Methods
<br />FORM 400C-01 CENTRAL
<br />Limited and Special Use Buildings Climate Zones 4 5 6
<br />Project Name: Zone:
<br />Address: Building Classification:
<br />City, Zip Code: Building Permit No.:
<br />Builder: Permitting Office:
<br />Owner: Jurisdiction No.:
<br />
<br /> ION
<br />WALLS ROOF/CEILING FLOORS DOORS GLASS
<br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA f'{PE U AREA
<br />Concrete (CBS\ loS !l~'Y Under Attic .t'F. Ie. Li) Slab-on-orade 6 fC/^ Wood Sinole wall
<br />Wood frame Sino Ie Assemblv Raised Wood Metal ,Il'" ~I.\. Double, wall - :L70
<br />Metal frame .OJ r "/L 1\ Other. Raised Concrete Insulated Sinole roof
<br />Insulation R-vaJue Ie- Insulation R-value p:fl Insulation R-value other Double, roof
<br />
<br /> " SYSTEMS INFORMATION
<br /> AIR CONDITIONER HEATING SYSTEM HOT WATER
<br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUlH TYPE
<br />Unitary & Heat Pump Central & Heat Pump Electric
<br /><65,000 Btulh _ SEER - <65,000 Btulh _ HSPF ~ Resistance ~
<br />~65,OOO Btulh J~ .1- EER _IPLV 5- ;&5,000 Btu/h -L COP Dedicated Heat Pump 0
<br />Water cooled _EER _'PLV - Water cooled _COP - Gas
<br />Evaporatively cooled _EER - Evaporatively cooled _COP - Natural 0
<br />PTAC _EER - Electric Resistance _COP - LPG 0
<br />Chiller _COP _IPLV - Gas/Oil (circle one) HRU 0
<br />Gas heat pump _COP - <225,000/300,000 Btulh _ AFUE - other. 0
<br />Other: - - - ~25,OOO/300,OOO Btulh _E, -
<br />LIGHTING Total Lighting Wattage d- 00 0 {.01- I SIZING CALCULATION I DUCTS R-value
<br />Total Conditioned Floor Area fq~ 0 Watts/sq.ft. Attached 0 Location
<br />
<br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.)
<br />Components Section Requirements Check
<br />Operations Manual 102.1 Operations manual will be provided to owner. 1\
<br />Windows & Doors 406.1 Maximum: .3 cfm per sq.ft. of window area; Maximum: 1.2 cfm per so.ft. of door area. ^
<br />Joints/Cracks 406.1 To be caulked, gasketed, weatherstripped or otherwise sealed. "J\
<br />Dropped Ceiling CavltV 406.1 Vented: seal and insulate ceilino (no T-bar ceilinos). Unvented, no ceilino air barrier. seal and insulate roof and side walls. .o~
<br />Reheat 407.1 Electric resistance reheat prohibited. ,,;~
<br />Ventilation 409.1 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required. '1l
<br />HVAC Efficiency 407.1,408.1 Minimum efficiencles - Heatino: Tables 4-7, 4-8, 4-9. Cooling: Tables 4-3, 4-4, 4-5, 4-6. X
<br />HVAC Controls 407.1 Separate readily accessible manual or automatic thennostat for each system. )t
<br />HVAC Ducts 410.1 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated - )\
<br /> and installed in accordance with the criteria of section 410.1.
<br />Balancing 410.1 HVAC distribution system(s) tested and balanced. ""-
<br />Piping Insulation 411.1 In accordance with Table 4-11. )(
<br />Water Heaters 412.1 Automatic electric storage water heaters ,,120 gallons and gas & oil fired storage water heaters ,,;75,000 Btulh shall meet
<br /> perfonnance requirements in Table 4-12. Electric> 120 gallons: standby loss ".30+27 NT. Gas >75,000, Oil >105,000: E, .78, ~
<br /> Standby loss" 1.30+114NT. Gas, Oil >155,000: E,.78, Standby loss" 1.30+95NT.
<br />Swimming Pools 412.1 Spas & heated pools must have covers. Non-commerclal pools must have pump timer. Gas spa & pool heaters must J.I/1
<br />& Spas have a minimum thennal efficiency of 78%.
<br />Hot Water Pipe 412.1 Piping heat loss is limited to the levels in Table 4-11 for circulating systems and the first 8' of pipe from a storage JIf-f1
<br />Insulation tank.
<br />Water Fixtures 412.1 Shower head water flow restricted to maximum of 2.5 gpm at 80 psi. Toilets meet 42CFR 6295(k). Public lavatory fixture fJr
<br /> maximum flow of .5 gpm; or if self-closing valve, .25 gallon circulating, .5 gallon non-circulating.
<br />Lighting 415.1 Ballasts shall have Power Factors no less than .90. l
<br />
<br />If required by Florida law, I hereby certify that the system design is in compliance with the Florida Energy Code.
<br />ARCHITECT:
<br />ELECTRICAL SYSTEM DESIGNER:
<br />LIGHTING SYSTEM DESIGNER:
<br />MECHANICAL SYSTEM DESIGNER:
<br />PLUMBING SYSTEM DESIGNER:
<br />
<br />Registration No.
<br />
<br />Compliance with Chapter 4 was demonstrated by a Prescriptive Measures methOdology:
<br />
<br />Detached Buildings <200 sq.ft. 0 Convenience stores <5,000 sq.ft.
<br />Skyboxes/sports stadiums 0 Restaurants <5,000 sq.ft.
<br />Traffic safety control towers 0 Retail stores <5,000 sq.ft.
<br />
<br />o
<br />o
<br />~
<br />
<br />Office buildings <5,000 sq.ft.
<br />School buildings <5,000 sq.ft.
<br />Storage buildings <5,000 sq.ft.
<br />
<br />o
<br />o
<br />D
<br />
<br />
<br />I hereby certify that the
<br />Florida Energy Code.
<br />
<br />cifications covered by the calculation are in compliance with the
<br />
<br />f-''j-oV
<br />
<br />Review of plans and specifications covered by this calculation indicates compliance with
<br />the Fk)rida Energy Code. Before construction is completed, this building will be inspected
<br />for compliance in acoordance with Section 553.908, F.S.
<br />
<br />OWNER AGENT:
<br />
<br />DATE:
<br />
<br />BUILDING OFFICIAL:
<br />DATE:
<br />
|