Laserfiche WebLink
<br />"t. <br /> <br />tJAJlf") <br /> <br />. , <br /> <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> CHAPTER 4 - Commercial Building Compliance Methods <br />FORM 400C-01 CENTRAL <br />Limited and Special Use Buildings Climate Zones 4 5 6 <br />Project Name: Zone: <br />Address: Building Classification: <br />City, Zip Code: Building Permit No.: <br />Builder: Permitting Office: <br />Owner: Jurisdiction No.: <br /> <br /> ION <br />WALLS ROOF/CEILING FLOORS DOORS GLASS <br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA f'{PE U AREA <br />Concrete (CBS\ loS !l~'Y Under Attic .t'F. Ie. Li) Slab-on-orade 6 fC/^ Wood Sinole wall <br />Wood frame Sino Ie Assemblv Raised Wood Metal ,Il'" ~I.\. Double, wall - :L70 <br />Metal frame .OJ r "/L 1\ Other. Raised Concrete Insulated Sinole roof <br />Insulation R-vaJue Ie- Insulation R-value p:fl Insulation R-value other Double, roof <br /> <br /> " SYSTEMS INFORMATION <br /> AIR CONDITIONER HEATING SYSTEM HOT WATER <br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUlH TYPE <br />Unitary & Heat Pump Central & Heat Pump Electric <br /><65,000 Btulh _ SEER - <65,000 Btulh _ HSPF ~ Resistance ~ <br />~65,OOO Btulh J~ .1- EER _IPLV 5- ;&5,000 Btu/h -L COP Dedicated Heat Pump 0 <br />Water cooled _EER _'PLV - Water cooled _COP - Gas <br />Evaporatively cooled _EER - Evaporatively cooled _COP - Natural 0 <br />PTAC _EER - Electric Resistance _COP - LPG 0 <br />Chiller _COP _IPLV - Gas/Oil (circle one) HRU 0 <br />Gas heat pump _COP - <225,000/300,000 Btulh _ AFUE - other. 0 <br />Other: - - - ~25,OOO/300,OOO Btulh _E, - <br />LIGHTING Total Lighting Wattage d- 00 0 {.01- I SIZING CALCULATION I DUCTS R-value <br />Total Conditioned Floor Area fq~ 0 Watts/sq.ft. Attached 0 Location <br /> <br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.) <br />Components Section Requirements Check <br />Operations Manual 102.1 Operations manual will be provided to owner. 1\ <br />Windows & Doors 406.1 Maximum: .3 cfm per sq.ft. of window area; Maximum: 1.2 cfm per so.ft. of door area. ^ <br />Joints/Cracks 406.1 To be caulked, gasketed, weatherstripped or otherwise sealed. "J\ <br />Dropped Ceiling CavltV 406.1 Vented: seal and insulate ceilino (no T-bar ceilinos). Unvented, no ceilino air barrier. seal and insulate roof and side walls. .o~ <br />Reheat 407.1 Electric resistance reheat prohibited. ,,;~ <br />Ventilation 409.1 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required. '1l <br />HVAC Efficiency 407.1,408.1 Minimum efficiencles - Heatino: Tables 4-7, 4-8, 4-9. Cooling: Tables 4-3, 4-4, 4-5, 4-6. X <br />HVAC Controls 407.1 Separate readily accessible manual or automatic thennostat for each system. )t <br />HVAC Ducts 410.1 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated - )\ <br /> and installed in accordance with the criteria of section 410.1. <br />Balancing 410.1 HVAC distribution system(s) tested and balanced. ""- <br />Piping Insulation 411.1 In accordance with Table 4-11. )( <br />Water Heaters 412.1 Automatic electric storage water heaters ,,120 gallons and gas & oil fired storage water heaters ,,;75,000 Btulh shall meet <br /> perfonnance requirements in Table 4-12. Electric> 120 gallons: standby loss ".30+27 NT. Gas >75,000, Oil >105,000: E, .78, ~ <br /> Standby loss" 1.30+114NT. Gas, Oil >155,000: E,.78, Standby loss" 1.30+95NT. <br />Swimming Pools 412.1 Spas & heated pools must have covers. Non-commerclal pools must have pump timer. Gas spa & pool heaters must J.I/1 <br />& Spas have a minimum thennal efficiency of 78%. <br />Hot Water Pipe 412.1 Piping heat loss is limited to the levels in Table 4-11 for circulating systems and the first 8' of pipe from a storage JIf-f1 <br />Insulation tank. <br />Water Fixtures 412.1 Shower head water flow restricted to maximum of 2.5 gpm at 80 psi. Toilets meet 42CFR 6295(k). Public lavatory fixture fJr <br /> maximum flow of .5 gpm; or if self-closing valve, .25 gallon circulating, .5 gallon non-circulating. <br />Lighting 415.1 Ballasts shall have Power Factors no less than .90. l <br /> <br />If required by Florida law, I hereby certify that the system design is in compliance with the Florida Energy Code. <br />ARCHITECT: <br />ELECTRICAL SYSTEM DESIGNER: <br />LIGHTING SYSTEM DESIGNER: <br />MECHANICAL SYSTEM DESIGNER: <br />PLUMBING SYSTEM DESIGNER: <br /> <br />Registration No. <br /> <br />Compliance with Chapter 4 was demonstrated by a Prescriptive Measures methOdology: <br /> <br />Detached Buildings <200 sq.ft. 0 Convenience stores <5,000 sq.ft. <br />Skyboxes/sports stadiums 0 Restaurants <5,000 sq.ft. <br />Traffic safety control towers 0 Retail stores <5,000 sq.ft. <br /> <br />o <br />o <br />~ <br /> <br />Office buildings <5,000 sq.ft. <br />School buildings <5,000 sq.ft. <br />Storage buildings <5,000 sq.ft. <br /> <br />o <br />o <br />D <br /> <br /> <br />I hereby certify that the <br />Florida Energy Code. <br /> <br />cifications covered by the calculation are in compliance with the <br /> <br />f-''j-oV <br /> <br />Review of plans and specifications covered by this calculation indicates compliance with <br />the Fk)rida Energy Code. Before construction is completed, this building will be inspected <br />for compliance in acoordance with Section 553.908, F.S. <br /> <br />OWNER AGENT: <br /> <br />DATE: <br /> <br />BUILDING OFFICIAL: <br />DATE: <br />