Laserfiche WebLink
<br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> CHAPTER 4 - Commercial Building Compliance Methods <br />FO~M 400C-01 CENTRAL <br />limited and Special Use Buildings Climate Zones 4 5 6 <br />Project Name: Zone: <br />Address: Building Classification: <br />City, Zip Code: Building Permit No.: <br />Builder: Permitting Office: <br />Owner: Jurisdiction No.: <br /> <br />(;1.--;1;' Dr-u &- <br /> <br />7i oy t <br /> <br /> EIUILDING IN/"ORMA ION <br />WALLS ROOF/CEILING FLOORS DOORS GLASS <br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA YPE U AREA <br />Concrete (CBS ,IUI I -<:! 1 Under Attic ~.. ~ Slab-on-orade LI 1 1'< tl;;l 1 Wood SinQle wall <br />Wood frame , Sinote Assemblv Raised Wood Metal W- 4/l,Cj Double wall ,~ .'1 Lo " <br />Metal frame lfO\"I ~",'.< Other: Raised Concrete Insulated Sino Ie, roof <br />Insulation R-value kT Insulation R-value 11.'1 Insulation R-value Other Double, roof <br /> <br /> SYSTEMS INFORMATION <br /> AIR CONDITIONER HEATING SYSTEM HOT WATER <br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUIH TYPE <br />Unitary & Heat Pump ~ Central & Heat Pump Electric <br /><65,000 Btulh _ SEER <65,000 Btulh _ HSPF 4"tlt' 0 Resistance ril. <br />;0,65,000 Btulh .lGJl=ER _IPLV - ;,65,000 Btu/h ..1.- COP Dedicated Heat Pump 0 <br />Water cooled _EER _IPLV - Water cooled _COP - Gas <br />Evaporatively cooled _EER - Evaporatively cooled _COP - Natural 0 <br />PTAC _EER - Electric Resistance _COP - LPG 0 <br />Chiller _COP _IPLV - Gas/Oil (circle onll) HRU 0 <br />Gas heat pump _COP - <225,000/300,000 Btulh _ AFLJE - Other: 0 <br />Other: >225,000/300,000 Btulh E, <br />LIGHTING Total Lighting Wattage .J- '{ 00 *''fU I SIZING CALCULATION I DUCTS R-value l> <br />Total Conditioned Floor Area G "0 t> Watts/sq.ft. Attached 0 Location <br /> <br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.) <br />Components SectIon Requirements Check <br />Operations Manual 102.1 Operations manual will be provided to owner. )( <br />Windows & Doors 406.1 Maximum: .3 cfm per sq.ft. of window area; Maximum: 1.2 cfm Der sa.ft. of door area. y. <br />Joints/Cracks 406.1 To be caulked, Qasketed, weatherstripped or otherwise sealed, <br />Dropped Ceiling Cavity 406.1 Vented: seal and insulate ceiling (no T-bar ceilinQs). Unvented, no ceiling air barrier: seal and insulate roof and side walls. 1m <br />Reheat 407.1 Electric resistance reheat prohibited. Jj -11 <br />Ventilation 409.1 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required. <br />HVAC Efficiency 407.1,408.1 Minimum efficiencies - Heating: Tables 4-7, 4-8, 4-9. Cooling: Tables 4-3, 4-4, 4-5, 4-6. <br />HVAC Controls 407.1 Separate readily accessible manual or automatic thennostat for each system. ~ <br />HVAC Ducts 410.1 Air ducts, frttings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated " <br /> and installed in accordance with the criteria of section 410,1. <br />Balancing 410.1 HVAC distribution system(s) tested and balanced. " <br />Piping Insulation 411.1 In accordance with Table 4-11. .,.. <br />Water Heaters 412.1 Automatic electric storage water heaters ,;120 gallons and gas & oil fired storage water heaters ,;75,000 Btulh shall meet <br /> petfonnance requirements in Table 4-12. Electric >120 gallons: standby loss S30+27NT. Gas >75,000, Oil >105,000: E, .78, "'- <br /> Standby loss,; 1.30+114NT. Gas, Oil >155,000: E,.78, Standby loss:s; 1.30+95NT. <br />Swimming Pools 412.1 Spas & heated pools must have covers. Non-commercial pools must have pump timer. Gas spa & pool heaters must plI <br />& Spas have a minimum thennal efficiency of 78%. <br />Hot Water Pipe 412.1 Piping heat loss is limited to the levels in Table 4-11 for circulating systems and the first 8' of pipe from a storage JIiI <br />Insulation tank. <br />Water Fixtures 412.1 Shower head water flow restricted to maximum of 2.5 gpm at 80 psi. Toilets meet 42CFR 6295(k). Public lavatory fixture '" <br /> maximum flow of .5 gpm; or if self-closing valve, .25 gallon circulating, .5 gallon non-circulating. <br />Lighting 415.1 Ballasts shall have Power Factors no less than .90. 'I. <br /> <br />If required by Florida law, I hereby certify that the system design is in compliance with the Florida Energy Code. <br />ARCHITECT: <br />ELECTRICAL SYSTEM DESIGNER: <br />LIGHTING SYSTEM DESIGNER: <br />MECHANICAL SYSTEM DESIGNER: <br />PLUMBING SYSTEM DESIGNER: <br /> <br />Registration No. <br /> <br />Compliance with Chapter 4 was demonstrated by a Prescriptive Measures methodology: <br /> <br />Detached Buildings <200 sq.ft. 0 Convenience stores <5,000 sq.ft. <br />Skyboxes/sports stadiums 0 Restaurants <5,000 sq.ft. <br />Traffic safety control towers 0 Retail stores <5,000 sq.ft. <br /> <br />I hereby certify that th <br />Florida Energy Code. <br /> <br />o <br />EJ <br />~' <br /> <br />Office buildings <5,000 sq.ft. <br />School buildings <5,000 sq.fl. <br />Storage buildings <5,000 sq.fl. <br /> <br />o <br />o <br />o <br /> <br /> <br />~ ~ Ji-Cf <br /> <br />Review of plans and specifications covered by this calculation indicates campllance with <br />the Florida Energy Code. Before conSllUction is camplaled,this building will be Inspected <br />for compliance in accordance with Section 553.908, F.S. <br /> <br />BUILDING OFFICIAL: <br /> <br />DATE: <br /> <br />OWNER AGENT: <br /> <br />DATE: <br />