Laserfiche WebLink
<br />7) Outside of walls to be wrapped wi Tyvek or equiv. & Shingles to be <br />Rated for 110 mph windspeed. <br /> <br /> <br />8) Use approved shingles rated for 110mph wind speed applied per mfgr's <br />specifications over 30# felt <br />9) Use r11 min insulation in all outside 2x4 walls. Use r30 min insulation <br />in attic. Vapor barrier &Optional use r 30 insulation under floor <br />10) Use ~"ceiling gypsum fastened wi 5d cooler nails or drywall screws <br />@ 7" O.c. <br />10) Use ~"gypsum at interior walls fastened 7" o.c. max wi dry wall <br />Screws. <br />II)Egress rated windows (C25 SH or equiv) to be used in bedrooms. <br />12) gfi receptacles to be used at kitchen counter and in bathrooms. <br />13) Use afi receptacles in bedrooms. <br />14) Provide smoke alarms in each bedroom and in area outside bedroom <br />~orn. . L <br />5) umbing an electrical to con orm 0 F orida Building Code and all <br />ci and county codes and erformed b l' ontractors. <br />16) No untreate wood structural members or siding to be within 6" of . ., <br />grade. 2-;;;;.0 l- <br /> <br />NIfT rt-1 rl- \. <br /> <br />I hereby certify that with the completion of the above listed items that this ~r'l;' L <br />structure will be in conformance to section 1606 of the Florida Building (U\ 1'l... <br />Code, 2001 edition for a 11 Omph wind speed. <br /> <br />r <br /> <br />Respectfully, <br /> <br />David W. Smith, P.E. #53608 <br /> <br />