<br />FORM 600A-2001 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS: , , , <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPONENTS <br /> <br />Exterior Windows & Doors <br />Exterior & Adjacent Walls <br /> <br />I SECTION <br />.606.1.ABC.1.1 <br />1606.1.ABC,1,2,1 <br /> <br />Floors <br /> <br />I ~ <br />I 606,1,ABC,1.2.2 <br /> <br />Ceilings <br /> <br />. 606.1,ABC.1.2.3 <br /> <br />Recessed Lighting Fixtures <br /> <br />606.1.ABC,1,2.4 <br />I <br />I-- <br />I 606.1.ABC.1.2.5 <br />1606.1,ABC.1.3 ' <br /> <br />Multi-story Houses <br />Additional Infiltration reqts <br /> <br />PERMIT #: <br /> <br />REQUIREMENTS FOR EACH PRACTICE <br />i Maximum:.3 cfm/sq.ft, windo"". ar~~ ,5 cfm/sq.ft. door area, <br />i Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br />I foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br />I penetrations; between wall panels & top/bottom plates; between walls and floor. <br />EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br />I from, and is sealed to, the foundation to the top plate. <br />Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br />, EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />. to the perimeter, penetrations and seams. ,. __ _ _ __ <br />Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br />soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br />attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />ins_tailed that is sealed_aJ the perimeter, at penetrations and seams, . <br />Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br />I sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br />i conditionedspa_~, tested,-_ _ _ _____ ____ <br />-LAir barrier 011 perimeter of floor cavity between floors. ._.___m_______ <br />i Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br />i have combustion air. <br /> <br />CHECK <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.) <br />COMPONENTS SECTION REQUIREMENTS - -- ------------ ------- cli~ <br /> -- -.- --- - --- .. ----- <br />Water Heaters 1612.1 i Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit <br />~. ---~ i brea_ker (electric) o~cutoff (gas) mUlltb~erovided,- Ex!ernal or built-in heattrap required. u_ __ <br />Swimming Pools & Spas ! Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> , ! must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br />. ~: _j efficienc:yo.f78%, --- ',------------- -------------- --- <br />Shower heads 612.1 ., .lI\fater f10wlllust be restrict~d_!o_no more !han 2.5 gallons per minute at 80 PSIG, '" ___ - ~- <br />Air Distribution Systems 610.1 ! All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610, <br />-.-_.. I Ducts in unconditioned attics: R-6 min, insulation. -- <br /> ._---------,--- - ".. -----------...- -~ ---------- --- <br />HVAC Controls ! 607.1 ' Separat~ readily accessible manual Clr automatic thermostat for each syste~.__ <br />Insulation 604.1, 602.1 Ceilings-Min, R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> I Common ceiling & floors R-11, <br /> <br />EnergyGaugeâ„¢ DCA Form 600A-2001 <br /> <br />EnergyGauge@/FlaRES'2001 FLRCSB v3.30 <br />