<br />FORM 600A-2001
<br />
<br />Code Compliance Checklist
<br />Residential Whole Building Performance Method A - Details
<br />
<br />I ADDRESS: , , ,
<br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
<br />
<br />COMPONENTS
<br />
<br />Exterior Windows & Doors
<br />Exterior & Adjacent Walls
<br />
<br />I SECTION
<br />.606.1.ABC.1.1
<br />1606.1.ABC,1,2,1
<br />
<br />Floors
<br />
<br />I ~
<br />I 606,1,ABC,1.2.2
<br />
<br />Ceilings
<br />
<br />. 606.1,ABC.1.2.3
<br />
<br />Recessed Lighting Fixtures
<br />
<br />606.1.ABC,1,2.4
<br />I
<br />I--
<br />I 606.1.ABC.1.2.5
<br />1606.1,ABC.1.3 '
<br />
<br />Multi-story Houses
<br />Additional Infiltration reqts
<br />
<br />PERMIT #:
<br />
<br />REQUIREMENTS FOR EACH PRACTICE
<br />i Maximum:.3 cfm/sq.ft, windo"". ar~~ ,5 cfm/sq.ft. door area,
<br />i Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
<br />I foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
<br />I penetrations; between wall panels & top/bottom plates; between walls and floor.
<br />EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
<br />I from, and is sealed to, the foundation to the top plate.
<br />Penetrations/openings >1/8" sealed unless backed by truss or joint members.
<br />, EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
<br />. to the perimeter, penetrations and seams. ,. __ _ _ __
<br />Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
<br />soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
<br />attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
<br />ins_tailed that is sealed_aJ the perimeter, at penetrations and seams, .
<br />Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a
<br />I sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
<br />i conditionedspa_~, tested,-_ _ _ _____ ____
<br />-LAir barrier 011 perimeter of floor cavity between floors. ._.___m_______
<br />i Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
<br />i have combustion air.
<br />
<br />CHECK
<br />
<br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.)
<br />COMPONENTS SECTION REQUIREMENTS - -- ------------ ------- cli~
<br /> -- -.- --- - --- .. -----
<br />Water Heaters 1612.1 i Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
<br />~. ---~ i brea_ker (electric) o~cutoff (gas) mUlltb~erovided,- Ex!ernal or built-in heattrap required. u_ __
<br />Swimming Pools & Spas ! Spas & heated pools must have covers (except solar heated). Non-commercial pools
<br /> , ! must have a pump timer. Gas spa & pool heaters must have a minimum thermal
<br />. ~: _j efficienc:yo.f78%, --- ',------------- -------------- ---
<br />Shower heads 612.1 ., .lI\fater f10wlllust be restrict~d_!o_no more !han 2.5 gallons per minute at 80 PSIG, '" ___ - ~-
<br />Air Distribution Systems 610.1 ! All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
<br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610,
<br />-.-_.. I Ducts in unconditioned attics: R-6 min, insulation. --
<br /> ._---------,--- - ".. -----------...- -~ ---------- ---
<br />HVAC Controls ! 607.1 ' Separat~ readily accessible manual Clr automatic thermostat for each syste~.__
<br />Insulation 604.1, 602.1 Ceilings-Min, R-19. Common walls-Frame R-11 or CBS R-3 both sides.
<br /> I Common ceiling & floors R-11,
<br />
<br />EnergyGaugeâ„¢ DCA Form 600A-2001
<br />
<br />EnergyGauge@/FlaRES'2001 FLRCSB v3.30