Laserfiche WebLink
<br />Page 1 <br /> <br />Residential Heat Loss and Heat Gain Calculation <br />In accordance with ACCA Manual J <br /> <br />10/22/2004 <br /> <br />Report Prepared By: <br /> <br />Chris' AlC Company <br /> <br />For: <br /> <br />CONKLINNILLAGE sa <br /> <br />ZEPHYRHILLS, FL <br /> <br />Design Conditions: Tampa <br /> <br />Indoor: <br />Summer temperature: 75 <br />Winter temperature: 72 <br />Relative humidity: 50 <br /> <br />Building Component <br /> <br /> Outdoor: <br /> Summer temperature: 95 <br /> Winter temperature: 34 <br /> Summer grains of moisture: 116 <br /> Daily temperature range:Medium <br />Sensible Latent Total Total <br />Gain Gain Heat Gain Heat Loss <br />(BTUH) (BTUH) (BTUH) (BTUH) <br />16,566 2,443 19,009 18,297 <br />16,566 2,444 19,010 18,298 <br />5,588 992 6,580 7,367 <br />1,023 394 1,417 1 ,455 <br />2,036 230 2,266 792 <br />908 0 908 534 <br />1,681 332 2,013 1,937 <br />626 0 626 612 <br />3,518 455 3,973 3,912 <br />281 0 281 752 <br />905 41 946 937 <br />16,566 2,443 19,009 18,297 <br /> <br />Whole House <br />First Floor <br />Living Room <br />Dining Room <br />Kitchen <br />Laundry <br />BED 2 <br />HALL BATH <br />MASTER <br />WIC <br />M1BA TH <br /> <br />Whole House <br /> <br />HVAC-Calc Residential 4,0 by HVAC Computer Systems Ltd. <br />LOIld calculalions are estimal8s only. actual loads may vary d....lD W88lher and construction dilfer8nces, <br /> <br />888736-1101 <br />