My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
04-3632
Zephyrhills
>
Building Department
>
Permits
>
2004
>
04-3632
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 3:21:46 PM
Creation date
2/8/2007 11:34:42 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
04-3632
Building Department - Name
THE YOUNG GROUP
Address
5914 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />EXTINGUISHING AGENT <br /> <br />ANSULEX Low pH Liquid Fire Suppressant (1.5 gallon - Part No. <br />79694 or 3.0 gallon - Part No. 79372) is a potassium-based solu- <br />tion designed for fast knock-down and suppression of grease- <br />related fires. The agent is shipped in plastic containers which pro- <br />vide one complete tank charge. Agent storage life expectancy is <br />twelve years. The distributor must record the batch numbers and <br />date of shipment receipt to be filed with each installation record. <br /> <br />"ANSUlEX" laN pH uaUID ARE SUPPRESSANT <br /> <br /> <br /> <br />. <br /> <br />3.0 GALLON <br />SHIPPING WT. 35 LB. (16 kg) <br />000136 <br /> <br />1.5 GAllON <br />SHIPPING WT. 19 LB. (9 kg) <br />000137 <br /> <br />RGURE 1 <br /> <br />REGULATED RELEASE ASSEMBLY (MECHANICAL) <br /> <br />The ANSUL AUTOMAN Regulated Mechanical Release Assembly <br />(Part No. 429853) contains the regulated release mechanism, <br />expellant gas hose for agent tank hookup, and enclosure knock- <br />outs to facilitate installing actuation piping; expellant piping; detec- <br />tion system; and additional equipment. This regulated release <br />assembly is used in single, double, and multiple-tank systems and <br />must be mounted to a rigid surface. The release mechanism can <br />be used to interconnect both the actuation and expellant gas lines <br />as required per system design. The regulator is designed to allow <br />a constant flow of gas into the tank at 110 psi (759 kPa) when the <br />system is actuated. The agent tank must be ordered separately. <br /> <br />In single, double, and multiple-tank systems, the provided expel- <br />lant gas hose connects the agent tank to the bottom outlet of the <br />regulator. In double and multiple-tank system configurations, the <br />back outlet of the regulator is used as an expellant gas feed for <br />one additional tank-enclosure or tank-bracket hookup. The enclo- <br />sure contains the required knockouts to facilitate this connection. <br />If a pressure switch is to be attached to the regulator, additional fit- <br />tings are required. <br /> <br />· The tank (ordered separately) is mounted within the enclosure. <br />The tank contains an adaptorltube assembly with a burst disc <br />union. The burst disc helps prevent siphoning of the agent up the <br />pipe due to significant temperature fluctuations in the area where <br />the tank is located. The tank is mild steel and, under normal con- <br />ditions, requires hydrostatic testing every twelve years. <br /> <br />The detection and additional equipment required per system <br />design are connected to the release mechanism. The enclosure <br />contains knockouts to facilitate detection and additional hookups. <br /> <br />The system can be actuated automatically or manually. Automatic <br />actuation occurs when a fusible link within the detection system <br />separates in a fire condition. Manual actuation of the system <br />occurs when personnel pull on the remote manual pull station <br />pull ring. <br /> <br />SECTION III - SYSTEM COMPONENTS <br />UL EX. 3470 ULC CEx747 Page 3-1 <br />10-1-02 REV. 3 <br /> <br />"ANSUL AUTOMAN" REGULATED RELEASE ASSEMBLY <br />(MECHANICAL) <br /> <br />. <br /> <br /> <br />NOTE: AGENT TANK MUST BE <br />ORDEREDSEPARArElY <br />· OR SEE PAGE 3-4 <br /> <br />~ <br /> <br />REGULATOR <br />SHIPPING WT. 25 lB. (11 kg) <br /> <br />RGURE 2 <br />000138 <br /> <br />REGULATED RELEASE ASSEMBLY (ELECTRICAL) <br /> <br />The ANSUL AUTOMAN Regulated Electrical Release Assembly <br />(Part No. 429856) is identical to the mechanical version exCept it <br />· also contains a factory installed 120 VAC solenoid and electrical <br />switch. <br /> <br />The solenoid is used to provide electrical actuation of the release <br />mechanism. The electric switch is used to protect the solenoid by <br />opening the circuit to the solenoid once the system is fired. <br />Additional electrical switches can be added as required for auto- <br />matic equipment and gas shut-off accessories, as well as initiating <br />audible and visual alarms. <br /> <br />...) <br /> <br />~ <br /> <br />"ANSUL AUTOMAN" REGULATED RELEASE ASSEMBLY <br />(ELECTRICAL) <br /> <br />. <br /> <br /> <br />SOlENOID <br /> <br />NOTE: AGENT TANK MUST BE <br />ORDERED <br />SEPARATELY <br />. OR SEE PAGE 3-4 <br /> <br />t <br />J <br /> <br />SWITCH <br /> <br />~ <br /> <br />SHIPPING WT. 34 lB. (15 kg) <br /> <br />FIGURE 3 <br />000130 <br />
The URL can be used to link to this page
Your browser does not support the video tag.