My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
04-3632
Zephyrhills
>
Building Department
>
Permits
>
2004
>
04-3632
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 3:21:46 PM
Creation date
2/8/2007 11:34:42 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
04-3632
Building Department - Name
THE YOUNG GROUP
Address
5914 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />DISTRIBUTION PIPING REQUIREMENTS (Continued) <br /> <br />Distribution Piping Requirements - 9,0 Gallon System <br /> <br />. This optional configuration consists only of three 3-gallon tanks, all <br />. pressurized from a single double-tank nitrogen cartridge with <br />. expellant gas hoses connected as shown in Figure 88. Tanks No. <br />1 and NO.2 must be connected directly to the regulator with sepa- <br />rate expellant gas hoses and Tank No. 3 must be connected to <br />. Tank No.2 with a third expellant gas hose as shown in Rgure 88. <br />Each tank must be connected to an independent distribution pip- <br />. ing network as shown in Figure 88. Distribution piping require- <br />ments for each network must be as follows: <br /> <br />1. The maximum leng1h between the start of the first branch line <br />and the start of the last branch line must not exceed 24 ft. <br />(7.3 m). When the supply line is split, the combined total of <br />both legs of the supply line (from the start of the first branch <br />line to the start of the last branch line) must not exceed 24 ft. <br />(7.3 m). See Figure 84. <br /> <br />2. The total length of all branch lines must not exceed 36 ft. <br />(10.9 m). See Figure 84. <br /> <br />3. Use a 318 in. union to connect the tank adaptor to the 3/8 in. <br />supply line. <br /> <br />4. A maximum of two nozzles are allowed per duct branch line. <br /> <br />5. When using this 9.0 gallon system configuration, no mani- <br />folding of distribution piping is allowed. <br /> <br />6. When an ANSUL AUTOMAN Regulated Release is utilized in <br />this configuration, additional regulator actuators cannot be <br />used. <br /> <br />. 7. Only 3 gallon tanks can be utilized in this configuration. <br /> <br />I 8. The requirements of the following table must not be exceeded <br />. for each 3 gallon tank: <br /> <br />. <br /> <br />. <br /> <br />Requirements <br />Pipe Size <br />Maximum Length <br /> <br />Supply Line <br />3/8 in. <br />40 ft. <br />(12.2 m) <br />6 ft. <br />(1 .8 m) <br />9 <br /> <br />Duct <br />Branch Line <br /> <br />3/8 in. <br /> <br />8 ft. <br />(2.4 m) <br /> <br />4 ft. <br />(1.2 m) <br /> <br />4 <br /> <br />Maximum Rise <br /> <br />Maximum 900 <br />Elbows <br /> <br />Maximum Tees <br /> <br />Maximum Flow <br />Numbers <br /> <br />11* <br /> <br />2 <br />4 <br /> <br />SECTION IV - SYSTEM DESIGN <br />UL EX. 3470 ULC CEx747 Page 4-49 <br />10-1-02 REV. 2 <br /> <br />~~ <br />r~~ <br />F~~ <br /> <br /> <br />D D <br /> <br />3.0 <br />GALLON <br />TANK <br />NO.3 <br /> <br />. <br /> <br />"I'M> TANK ENCLOSURE <br />ASSEMBLY PART NQ <br />419604 (INCLUOES (2) <br />HOSES AND (2) <br />GROMMETS) <br /> <br />3.0 <br />GALLON <br />TANK <br />NO.2 <br /> <br />3 GALLON REGULATED DOUBLE TANK NITROGEN <br />RELEASE ASSEMBLY, I CARTRIDGE OR <br />OR 3 GALLON LT-A-l01-30 CARTRIDGE <br />REGULATED ACTUATOR (REGULATED ACTlWOR <br />ASSEMBLY ONLY) <br /> <br />FIGURE 88 <br />0??oo7 <br /> <br />, <br /> <br />Appliance I <br />Branch Line <br />3/8 in. I <br />12 ft. <br />(3.7 m) <br />2 ft. <br />(.6 m) <br />6 <br /> <br />4 <br />4 <br /> <br />I <br /> <br />. <br /> <br />Plenum <br />Branch Line <br /> <br />3/8 in. <br /> <br />4 ft. <br />(1.2 m) <br /> <br />2 ft. <br />(.6 m) <br /> <br />4 <br /> <br />2 <br />2 <br /> <br />'Exceptions: <br />1. T_ (12) how numbers are allowed in any tank not containing two-flow appliance nozzles. and/or, a 1 N nozzla for wok or griddle protection. and/or, a 1 F nozzle for range protec- <br />tion, and/or, a 3N nozzle for fryer protection. <br />2. T_ (12) flow numbers are allowed with any one tank using only two-flow appliance nozzles. <br />3. T_ (12) flow numbers ere allowed with any one tank using only three.flow appliance nozzles. <br />SpeciallMtructlons: J <br />1. When four (4) Dean Industries GTI Gas Fryers are prolected at low proximity as shown in Figure 58 on Page 4-32, the discharge piping must be shown in Figure 59 on <br />Page 4-32. <br />2. For certain McDonald's applications, 11.5 flow numbers are allowed when using a combination of one (1) 2W duct nozzle, one (1) 1/2N e1ectrostallc precipitator nozzle, <br />one (1) 1N plenum nozzle, and four (4) two-flow appliance nozzles. Contact Ansul Applications Engineering Department for additional information. <br /> <br />. <br /> <br />. <br />. <br />
The URL can be used to link to this page
Your browser does not support the video tag.