Laserfiche WebLink
<br />FORM 400C-01 <br />METHOD C <br /> <br />PRESCRIPTIVE REQUIREMENTS L1ST* <br />'All Basic Prescriptive Requirements, designated in the Code by ".1.ABCD" and <br />summarized on the front of this form, must also be met. <br /> <br />CUMATE ZONES 4 5 6 <br /> <br />Glass Area: <br />Overhang: <br /> <br />Detached Commercial Buildings Less than 200 sq.ft. <br /> <br />Table 4C-1 <br /> <br />Walls: <br /> <br />Roofs/Ceilings: <br />Floors: <br />Cooling System: <br />Heating System: <br /> <br />No limit. <br />Minimum 1 foot if not under another structure; or <br />No overhang with a glazing Solar Heat Gain Coefficient of 0.48 or less. <br />Minimum insulation level <br />Frame walls - R-ll. <br />Masonry walls - R-5. <br />Minimum insulation level- R-19. <br />Minimum insulation level- None. <br />Code minimums as per section 407.1.ABCD.3. <br />Code minimums as per section 408.1.ABCD.3. <br /> <br />Skyboxes or Sports Stadiums <br /> <br />Glass: <br />Overhang: <br />Walls: <br /> <br />Roofs/Ceilings: <br />Floors: <br /> <br />Cooling System: <br /> <br />Heating System: <br />Air Distribution: <br /> <br />Lighting: <br /> <br />Table 4C-2 <br /> <br />No limit with glazing Solar Heat Gain Coefficient of 0.48 or less. <br />None required. <br />Minimum insulation level <br />Frame walls - R-ll. <br />Masonry walls - R-5. <br />Minimum insulation level- R-19. <br />Minimum insulation level <br />Frame floor - R-19. <br />Concrete floor - None. <br />Minimum equipment efficiency requirements <br />Air cooled -10.0 EER or 10.5 SEER. <br />Water cooled - 11.0 EER. <br />Code minimums as per section 408.1.ABCD.3. <br />A programmable setback shall be installed for in-season use; <br />At least one humidistat control per zone shall be installed for off-season use. <br />EXCEPTION: Installation of a central energy management system. <br />Total connected wattage shall not exceed 1.8 watts per square foot of conditioned space. <br /> <br />Traffic Safety COhtrol Towers <br /> <br />Glass: <br />Overhang: <br /> <br />Walls: <br /> <br />Roofs/Ceilings: <br />Floors: <br />Cooling System: <br />Heating System: <br />Lighting: <br /> <br />Table 4C-3 <br /> <br />No limit. <br />Minimum 1 foot if not under another structure; or <br />No overhang with a glazing Solar Heat Gain Coefficient of 0.48 or less. <br />Minimum insulation level <br />Frame walls - R-l1. <br />Masonry walls - R-5. <br />Minimum insulation level- R-19. <br />Minimum insulation level - None. <br />Code minimums as per section 407.1.ABCD.3. <br />Code minimums as per section 408.1.ABCD .3. <br />Total connected wattage shall not exceed 2.1 watts per square foot of conditioned space. <br /> <br />General Requirements for Building Packages <5,000 sq.ft. <br /> <br />Table 4C-4 <br /> <br />FLOOR: Slab-on-Grade R-O <br />Raised Wood R-19 <br />Raised Concrete R-7 <br />WALL: Masonry R-7 (exterior, adjacent and common) <br />Wood Frame R-l1 (exterior, adjacent and common) <br />Metal Frame R-13 (exterior, adjacent and common) <br />ROOF: Insulation above Deck R-19 <br />Insulation in Attic or Dropped Ceiling Cavity R-19 <br />INFILTRATION: Code minimums in section 406.1.ABCD.l <br />DUCTS: Code minimums in section 410.l.ABCD.2 <br />DOMESTIC HOT WATER: Code minimums in section 4l2.1.ABCD.3 <br />LIGHTING CONTROLS: Each space must have the lights divided into at least two "banks" - each one with a manual On/Off switch; <br />OR Each space must have one occupancy sensor (or other automatic control) to turn the lights on and off. <br /> <br />13.168 <br /> <br />FLORIDA BUILDING CODe - BUILDING <br /> <br />CHECK <br /> <br />L <br /> <br />=z= <br />~ <br /> <br />~ <br />-JtL- <br />~ <br />