Laserfiche WebLink
<br />Page 1 <br /> <br />Residential Heat Loss and Heat Gain Calculation <br />In accordance with ACCA Manual J <br /> <br />11/24/2004 <br /> <br />Report Prepared By: <br /> <br />Chris' Ale Company <br /> <br />For: <br /> <br />SANT VIL sa <br /> <br />ZEPHYRHILLS, FL <br /> <br />Design Conditions: Ocala <br /> <br />Indoor: <br />Summer temperature: 75 <br />Winter temperature: 72 <br />Relative humidity: 50 <br /> <br /> Outdoor: <br /> Summer temperature: 95 <br /> Winter temperature: 34 <br /> Summer grains of moisture: 116 <br /> Daily temperature range:Medium <br />Sensible Latent Total Total <br />Gain Gain Heat Gain Heat Loss <br />(BTUH) (BTUH) (BTUH) (BTUH) <br />30,753 4,593 35,346 30,266 <br />30,752 4,593 35,345 30,265 <br />5,759 840 6,599 4,954 <br />2,190 420 2,610 2,020 <br />3,079 344 3,423 1,917 <br />3,473 572 4,045 3,189 <br />1,636 489 2,125 2,494 <br />1,803 401 2,204 2,878 <br />1,517 171 1,688 1,355 <br />483 0 483 1,214 <br />3,846 515 4,361 3,558 <br />596 0 596 207 <br />67 0 67 88 <br />442 0 442 80 <br />3,567 468 4,035 4,153 <br />2,294 373 2,667 2,158 <br />30,753 4,593 35,346 30,266 <br /> <br />Building Component <br /> <br />Whole House <br />First Floor <br />Family Room <br />NOOK <br />Kitchen <br />Dining Room <br />Living Room <br />Study <br />LaundrylSTOR <br />Hall <br />MASTER <br />MASTER BATH <br />WIC <br />HALL BATH <br />BED3 <br />BED 4 <br /> <br />Whole House <br /> <br />HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. <br />Load calcublllons ... _"""- only, __loads may WI)' d<>> to ~ and conslrucIion diII'8nJnces. <br /> <br />888736-1101 <br />