Laserfiche WebLink
<br />Page 1 <br /> <br />Residential Heat Loss and Heat Gain Calculation <br />In accordance with ACCA Manual J <br /> <br />11/24/2004 <br /> <br />Report Prepared By: <br /> <br />Chris' AlC Company <br /> <br />For: <br /> <br />AGUSTA VIL SQR <br /> <br />ZEPHYRHILLS, FL <br /> <br />Design Conditions: Oeala <br /> <br />Indoor: <br />Summer temperature: 75 <br />Winter temperature: 72 <br />Relative humidity: 50 <br /> <br /> Outdoor: <br /> Summer temperature: 95 <br /> Winter temperature: 34 <br /> Summer grains of moisture: 116 <br /> Daily temperature range:Medium <br />Sensible Latent Total Total <br />Gain Gain Heat Gain Heat Loss <br />(BTUH) (BTUH) (BTUH) (BTUH) <br />26,753 3,395 30,148 25,484 <br />26,754 3,395 30,149 25,484 <br />8,337 1,556 9,893 8,427 <br />6,822 513 7,335 4,017 <br />1,322 164 1 ,486 1,918 <br />794 0 794 861 <br />382 0 382 975 <br />3,165 419 3,584 3,019 <br />2,019 324 2,343 2,053 <br />551 0 551 442 <br />3,362 419 3,781 3,772 <br />26,753 3,395 30,148 25,484 <br /> <br />Building Component <br /> <br />Whole House <br />First Floor <br />L1V/DIN <br />Kitchen <br />Laundry <br />M/BA TH <br />WIC <br />MASTER <br />BED2 <br />Bathroom <br />BED3 <br /> <br />Whole House <br /> <br />HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. <br />Load caleulalions.,.. esIimalIIs only. 8c:Iual1oeds IIIIIY vary due \0 WWIher and c:onsIrucIion diII'8nInces. <br /> <br />888 736-1101 <br />