Laserfiche WebLink
<br />Dale: 11/9/04 <br />Client Southwest Signs <br />Sian: Rubv "uesdav <br /> <br />City, State: Zephyrhills. FL <br />Overall Height: 12'-0" <br />Wind Saeed 110 mah <br /> <br />SHEET: 2 OF 3 <br />Sean M, McFarland, P,E. <br /> <br />Foundation: (Non-Constrained) <br />Pier Footing Design: <br />d = A 12 · (1 + (1 + (~.36 . h) 1 A)1\1/2)) <br />where A = (2.34 . P) I (51 · b) <br /> <br />Selec//he footing and soil type: <br />Footing: Round <br />Vert. Soil Bearing (psf): . 1500 <br />Lat. Soil Bearing (pst): . 150 <br /> <br />] <br /> <br />Mmax = <br /> <br />Pmax (Lateral) = <br />LSBP = <br />51 = <br />b= <br /> <br />28,342 #-FT <br />4,724 # <br />150 PCF <br />986 PCF X d <br />3.000 FT For use with Round Footing <br /> <br />A= <br /> <br />h= <br /> <br />d= <br /> <br />USE: <br /> <br />3.74 H^2 <br />6.000 FT . <br />7.151 FT ( I <br />~~ I <br /> <br />7.25 FT DEEP FOOTING I <br />~ <br /> <br />Soil Bearing Check: <br />DLmax = <br />Area of Footing = <br />Actural SBP = <br />Allowable SBP = <br /> <br />Concrete Volume: 1.80 <br /> <br />yd^3 <br /> <br />3,718 LBS <br />7.07 FT^2 <br />526 PSF <br />1,250 PSF <br /> <br />(Includes code allowed 20% increase for every foot <br />of fooling below 12" into natural grade.' <br /> <br />526 PSF < <br /> <br />1,250 PSF THEREFORE OK <br /> <br />General Notes <br />Contractor shall verify all dimensions and conditions on job site <br />2 Structural steel pipe shall conform to ASTM AS3 grade B type E or S, Fy=35 ksi min. <br />3 Structural steel tube shall conform to ASTM A500 grade B. Fy=46 ksi min. <br />4 Structural steel shapes and plates shall conform to ASTM A36. <br />5 Welding shall conform to AISC specs or local codes and performed by certified welder using arc process E70XX electrodes. <br />6 Isolate Aluminum from Steel per Chapter 20 (2002.1) 2000 IBC / 2000 Aluminum Design Manual (AA ASM 35 Pans 1.A /1-B) <br />7 All boll holes to be drHled or punched, <br />8 2500 psi (mln) 28 day concrete compressive strength <br />9 All electrical work to conform to the requirements of UL48 and section 600 of NEC, <br />10 Ul and Data labels required <br />11 Sign to be a minimum of 6.ft horizontal & 12-ft vertical from high voltage wires, <br /> <br />900~ <br /> <br />!O <br />:9, I 1, <br />6\, <br />~\ <br />.::::J <br />\ <br />17602 Forest Haven Drive. Tomball TX 77375 (281) 813-7439 <br /> <br /> <br />.UOlS ,.a~q,nos 0...... ~. <br /> <br /> <br />SO:ST SOOZ/TT/TO <br />