<br />/~ <br />AF-CKA -y ENG fNEEF-C fNG fNC. <br />STRUCTURAL ENGINEERS <br /> <br />April 13, 2005 <br /> <br />John L. Smith Construction, Inc. <br />4240 Coats Road <br />Zephyrhills, Florida 33541 <br /> <br />Attention: John Smith <br /> <br />Re: Interior Renovations for Ahad Mahootchi M.D. - Zephyrhills, FL <br />Arkay Engineering, Inc. Job # 8182 <br /> <br />Dear John: <br /> <br />I have evaluated the header beam requirements for the new openings to <br />be cut in the Lobby and Office areas of the above referenced project. <br />The rough openings shall be no more than 8'-0" in width. <br /> <br />Based upon the roof loads along this wall, the openings need to have <br />a triple 2" X 12" (#2 yellow pine) header beam (with 2 1/2" plywood <br />spacers) installed with a triple 2" X 6" (#2 yellow pine) studpack <br />at each ,enCl... Anchor the studpacks to the existing block wall with 1/4" <br />X 2 3/~"TAPCON screws spaced at 12" on center, strap the studpacks to <br />the be,ani,wii;h a>Simpson "LSTA21" on each face (the existing roof uplift <br />shall be ~es~s~~d by the existing masonry bond beams over the opening) . <br /> <br />. < '..r ~_ .' '" <br /> <br />If 'you need' any,'.iurther assistance with this matter, please give me a <br />call at ,the off~~e. <br /> <br /> <br />- <br /> <br />~ P.E. <br /> <br />- <br />- mail <br /> <br />5600 US ~WY. Gt8 NORiH - SUliE- #5 LAK.E-LAND, F-LORIDA 3380<1 <br />PHON~: 863-853-2711 F-AX: 863-816-2118 <br />S i A iE- OF- F-LORID A CE-R ilF-IC A iE- OF- AUiHORIZA ilON # E-66347 <br />RICHARD L. K.IDDE-Y, P.E-. - F-LORIDA L1CE-NSE- # 372Gt6 <br />