<br />FORM 400C-01
<br />
<br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br />CHAPTER 4 - Commercial Building Compliance Methods
<br />
<br />
<br />Zone:
<br />Building Classification:
<br />Building Permit No,:
<br />Permitting Office:
<br />Jurisdiction No.:
<br />
<br />
<br />CEN~AL
<br />Climate Zones(i)5 6
<br />
<br /> BUILDING INFORMATION
<br />WALLS ROOF/CEILING FLOORS DOORS GLASS
<br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA
<br />Concrete ICBS' I.DII ICl""D Under Attic Slab-on-orade ?'l'7~ Wood Sinole wall o::z
<br />Wood frame Sino Ie Assemblv .0 ',rn .. Aaised Wood Metal I.~ '? Double wall
<br />Metal frame Other: Aaised Concrete Insulated Sinole, roof
<br />Insulation A-vaiue 14-.2- Insulation R-value 20 Insulation A-value n Other Double, roof
<br />
<br /> SYSTEMS INFORMATION
<br /> AIR CONDITIONER HEATING SYSTEM HOT WATER
<br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUlH TYPE
<br />Unitary & Heat Pump g . "lb. 'Z 'EEA U Central & Heat Pump Electric
<br /><65,000 Btu/h <65,000 Btuth _ HSPF - Resistance 0
<br /><:65,000 Bluth _EER _IPLV - <:65.000 Btuth _COP - Dedicated Heat Pump 0
<br />Water cooled _EEA _IPLV - Water cooled _COP - Gas
<br />Evaporatively cooled _EER - Evaporatively cooled _COP b32a) Natural ~
<br />PTAC _EER - Electric Resistance _COP LPG
<br />Chiller _COP _IPLV - Gas/Oil (circle one) HRU 0
<br />Gas heat pump _COP - <225.000/300,000 Btu/h _ AFUE - Other: 0
<br />Other: 2225,000/300,000 Btu/h Er
<br />LIGHTING Total Lighting Wattage 5l3l,;; "2.'" I SIZING CALCULATION I DUCTS R-value to
<br /> - ,q;-O ~ 0 LocationA.~\I-CL~.
<br />Total Conditioned Floor Area Watts/sq.fl, Attached
<br />
<br /> PRESCRIPTIVE MEASURES (Must be mel or exceeded by all buildings.)
<br />Components Section Reauirements Check
<br />Operations Manual 102.1 Operations manual will be provided to owner. V
<br />Windows & Doors 406,1 Maximum: .3 cfm oer so.ft. of window area; Maximum: 1.2 cfm oer so.ft. of door area. V
<br />Joints/Cracks 406.1 To be caulked, gasketed, weatherstriooed or otherwise sealed. V
<br />Dropped Cellino Cav/tv 406.1 Vented: seal and insulate ceilino (no T-bar ceilings). Unvented, no ceiling air barrier: seal and insulate roof and side walls. V
<br />Reheat 407.1 Electric resistance reheat prohibited. ,/
<br />Ventilation . 409.1 Supolied with readily accessible switch far shut-off andlor volume reduction when ventilation is not required. V
<br />HV AC Efficiency 407.1,408.1 Minimum efficiencies - Heating: Tables 4-7, 4-8, 4-9. Cooiing: Tables 4-3, 4-4, 4-5, 4-6. /
<br />HV AC Controls 407.1 Separate readily accessible manual or automatic thermostat for each system. v'
<br />HV AC Ducts 410.1 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated
<br /> and installed in accordance with the criteria of section 410. ,. V
<br />Balancing 410.1 HVAC distribution system(s) tested and balanced. V
<br />Piping Insulation 411.1 In accordance with Table 4-11. v'
<br />Water Heaters 412.1 Automatic electric storage water heaters :>120 gallons and gas & oil fired storage water heaters :>75,000 Btu/h shall meet
<br /> performance requirements in Table 4-12. Electric> 120 gallons: standby loss :>.30+27NT. Gas >75,000, Oil >105,000: E, .7B, /'
<br /> Standby loss < 1.30+114/VT. Gas. Oil >155,000: E,.7B. Standby loss < 1.30+95/VT.
<br />Swimming Pools 412.1 Spas & heated pools must have covers. Non-commercial pools must have pump timer. Gas spa & pool heaters must
<br />& Spas have a minimum thermal efficiency of 78%.
<br />Hot Water Pipe 412,1 Piping heat loss is limited to the levels in Table 4-11 for circulating systems and the first B' of pipe from a storage
<br />Insulation tank. V'
<br />Water Fixtures 412.1 Shower head water flow restricted to maximum of 2.5 gpm at 80 psi, Toilets meet 42CFR 6295(k). Public lavatory fixture ,/
<br /> maximum fiow of .5 gpm; or if self-closing valve, '.25 gallon circulating, ,5 gallon non-circulating.
<br />Lighting 415.1 Ballasts shall have Power Factors no less than .90. V
<br />
<br />If required by Florida law, I hereby certify that the system design is in compliance with the Florida Energy Code.
<br />ARCHITECT M~I2.\4 D. joHfoJ"5otJ. A.IP.
<br />ELECTRICAL SYSTEM DESIGNER: II
<br />LIGHTING SYSTEM DESIGNER: II
<br />MECHANICAL SYSTEM DESIGNER: t:(Oe.Ci.RT ~ ~Ai~\) 'fie.
<br />PLUMBING SYSTEM DESIGNER: 0 ~E.~J2;::: J QH ~ '5 blJ , Jl.. \ ,.."
<br />
<br />Compliance with Chapter 4 was demonstrated by a Prescriptive Measures methodology:
<br />Detached BUIldings <200 sq. ft. 0 Convenience stores <5,000 sq. h
<br />Skyboxes/sports stadiums 0 Restaurants <5,000 sq.ft
<br />Traffic safety control towers 0 Retail stores <5,000 sqfl.
<br />
<br />Registration No.
<br />AlZ.~OOO
<br />A'e. 000
<br />A1Z.~OOO
<br />Fl.. ~S2.1
<br />t>-~ClOQO
<br />
<br />
<br />o
<br />~
<br />
<br />Office buildings <5,000 sq.ft.
<br />School buildings <5,000 sq.ft.
<br />Storage buildings <5,000 sq. fl.
<br />
<br />o
<br />o
<br />o
<br />
<br />OWNER AGENT:
<br />
<br />DATE
<br />
<br />
<br />BUILDING OFFICIAL:
<br />DATE:
<br />
<br />I hereby certify that Ihe plans
<br />Florida Energy Code
<br />
<br />n overed by the calculation are in compliance with the
<br />
<br />1-P/- () ':'-
<br />DATE:.. .____. _
<br />ce with the Florida Energy Code
<br />
<br />FLORIDA BUILDING CODe - BUILDING
<br />
<br />13.167
<br />
|