Laserfiche WebLink
<br />TABLE 6B-1 <br /> <br />COMPONENTS <br /> <br />MINIMUM REQUIREMENTS <br /> <br />PACKAGES FOR NEW CONSTRUCTION <br />BCD E <br /> <br />F <br />25% <br /> <br />UJ <br />UJ <br />:s <br />(!) <br /> <br />Max, 'loaf glass to Floor Area <br />Type <br />Overhang <br /> <br />A <br />15% <br /> <br />15% <br /> <br />20% <br /> <br />20% <br /> <br />25% <br /> <br />Double Clear (DC) Single Tint (S1') ouble Clear (DC) Single Tint (S1') <br />2' 1'4" 2' 2' <br /> <br />Double Tint (01') Double Tint (01') <br />2' 2' <br /> <br />Masonry <br /> <br />EXTERIOR AND ADJACENT MASONRY WALLS R-5 <br />COMMON MASONRY WALLS R-3 CH IDE. <br /> <br />UJ <br />..J <br />...J <br />< <br />:i: Wood <br /> <br />Frame <br /> <br /> <br />CEILINGS <br /> <br />E COMMON CEILINGS R-11. <br />CEILINGS ALLOWED) <br /> <br />UJ <br />a: <br />a <br />a <br />...J <br />u.. <br /> <br />Slab-On-Grade <br />Raised Wood <br />Raised Concrete <br /> <br />R-O <br />NSTRUCTION ALLOWED EXCEPT PACKAGE D) <br />R-5 <br /> <br /> <br />DUCTS <br />SPACE COOLING (SEER) <br />!;( Elect. <br />~ Gas/Oil (AFUE) <br /> <br />Electric <br />Resistance** <br /> <br />R-6 <br />12.0 <br />STRIP <br /> <br />R-6 <br />10.0. <br />6.8. <br /> <br />R-6 <br />10.0. <br />6.8* <br /> <br />R-6 <br />10.0* <br />6.8* <br /> <br />R-6 <br />10.9 <br />7.6 <br /> <br />EF .90 <br /> <br />EF .90 <br /> <br />NOT ALLOWED <br /> <br />(SEE BELOW) <br /> <br />NOT ALLOWED <br />(SEE BELOW) <br /> <br />a: <br />w;:E <br />....w <br /><.... <br />:i:UJ <br />....>- <br />aUJ <br />J: <br /> <br />Gas & Oil ** <br /> <br />MINIMUM EF OF .54 <br /> <br />NATURAL GAS ONLY <br />(SEE BELOW) <br /> <br />Other <br /> <br />Any of the following are allowed: dedicated heat pump. <br />heat recovery unit or solar system. <br /> <br />Climate Zones 4 5 6 <br /> <br />TO BE INSTALLED <br /> % <br />DC: 0 DT: 0 <br /> FEET <br />00: R= <br />ADJ: R= <br />COM: R- <br />EXT: R= <br />ADJ: R= <br />COM: R= <br />UNDER ATTIC: R = - <br />COMMON: R = <br />R= <br />R= <br />R= <br />R= - CONDo 0 <br />SEER = <br />COP= <br />AFUE = <br />EF= <br />EF = <br />DHP: tj EF= - <br />HRU: <br />SOLAR: 0 EF= - <br /> <br />Single package units minimum SEER=9,7, HSPF = 6,6, <br />Minimum efficlenCles for gas and electnc hot water systems appiy to to 40 gallon water heaters, Refer to Table 6-12 for minimum Code efficiencies for oil waler heaters and other sizes, <br /> <br />DESCRIPTION OF BUILDING COMPONENTS USTED <br />Percent of Glas. 10 Roor Area: This percentage is calculated by dividing the total of all glass areas by the total conditioned noer area, <br />Overhang: The overhang is the distance the rool or soffit projects out honzontally from the face of the glass, All glass areas shall be under an overhang of at least the prescnbed length with the following exceptions: 1) glass <br />on the gabled ends 01 a house and 2) the glass in the lower stories of a mufli.stol'f house. <br />WIll, Ceiling Ind Floor Insulation Vllues: The R-values indicated represent the minimum acceptable insulation level added to the structural components 01 the wall, ceiling or floor. The R-value 01 the structural bUilding <br />malenals shall not be included in this calculation. 'Common' components are those separating conditioned tenancies in a multifamily building. 'Adjacenr componenls separate conditioned space from unconditioned but <br />endosed space, .Exterior" components separate conditioned space from unconditioned and unenclosed space, <br />Floor: Slalron"9rade floors without edge insulation are acceptable, Raised wood noers shall have continuous stem walls with insulation placed on the stem wallar under the noor except Package 0, <br />Ducts: "CONO" indicates that the ducts must be installed within the conditioned space; that is, the ductwork shall be located on the conditioned side of the Insulation, Ducts in conditioned space are acceptable for any <br />prescriptive package, <br />Space Cooling System: Cooling systems shall have a Seasonal Energy Efficiency Ratio (SEER) lor central units or Energy Efficiency Ratio (EER) for room units or PT AC's equal to or greater than the prescnbed value, <br />Electric Spice Hllting Option: Heal pump systems shall be rated with a Heating Seasonal Performance Factor (HSPF) equal to or greater than the presenbed HSPF, Heal pump systems may contain eleclnc stnp backups <br />meeting the criteria of section 608.t.ABC,3.2.1,2. No electnc resistance space heat is allowed for these packages. <br />Electric Resistance Hot Water Option: For packages designated "Not Allowed", an electric resistance hot water syste:n may be installed only in conjunction with one of the "Other Hot Water System Options", See below, <br />Other Hot WIler System OptJons: My dedicated heat pump, heat recovel'f unit, or solar hot water system may be installed. Solar systems must have an EF of t,5 or higher, E1ectnc reSIStance systems haVIng an EF 01 ,88 <br />or greater, or natural gas systems with EF ,54 or greater may be used in conjunction with these systems, <br /> <br />TABLE 6B-21 MINIMUM REQUIREMENTS FOR ALL PACKAGES <br />COMPONENTS SECTION REQUIREMENTS ICHECK <br />Exterior Joints & Cracks 606.1 To be caulked, gasketed, weather-stripped or otherwise sealed. t/ <br />Exterior Windows & Doors: 606.1 Max ,3 cfm/sa.ft, window area; ,5 cfmtsa.ft. door area. ,/' <br />Sole & Top Plates 606.1 I Sole plates and penetrations through top plates of exterior walls must be sealed. ! V <br />Recessed Lighting I 606.1 Type IC rated with no penetrations (two alternatives allowed). <br />Multi-story Houses 606.1 Air barrier on perimeter of floor cavity between floors. I <br />Exhaust Fans 606,1 Exhaust fans vented to unconditioned space shall have dampers, except for combustion IV" <br /> devices with integral exhaust ductwork. <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) ;/ <br /> or cutoff (aas) must be orovided. External or built-in heat trap required, <br />Swimming 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a <br />Pools & Spas oumo timer, Gas soa & 0001 heaters must have minimum thermal efficiency of 78%. <br />Hot Water Pipes 612,1 Insulation is required for hot water circulating systems (including heat recovery units), <br />Shower Heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. V <br />HVAC Duct 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br />Construction, sealed. insulated and installed in accordance with the criteria of Section 610.1. Ducts in attics must be V" <br />Insulation & Installation insulated to a minimum of R-6. Air handlers in attics shall be within 5' of an attic access, have a radiant <br /> barrier installed above the ahu extending 10' in all directions & meet requirements of other codes. <br />HV AC Controls 607,1 Separate readily accessible manual or automatic thermostat for each system, t/ <br /> <br />-2- <br />