Laserfiche WebLink
<br />Page 1 <br /> <br />Residential Heat Loss and Heat Gain Calculation <br />---_..._--..__.,.~~-~-_. <br />In accordance with ACCA Manual J <br /> <br />Report Prepared By: <br /> <br />Chris' AlC Company <br /> <br />For: <br /> <br />PANZER RENTAL <br /> <br />ZEPHYRHILLS, FL <br /> <br />Design Conditions: Ocala <br /> <br />Indoor: <br />Summer temperature: <br />Winter temperature: <br />Relative humidity: <br /> <br />75 <br />72 <br />50 <br /> <br />Building Component <br /> <br />Sensible <br />Gain <br />(BTUH) <br /> <br />3/14/2005 <br /> <br />Outdoor: <br />Summer temperature: 95 <br />Winter temperature: 34 <br />Summer grains of moisture: 116 <br />Daily temperature range:Medium <br /> <br />Latent <br />Gain <br />(BTUH) <br /> <br />Total <br />Heat Gain <br />(BTUH) <br /> <br />----- ._----,- ------._.__.._-----.~---._-_.._-- ..-- ---._---- .----.-----.----- ----..------- <br /> <br />Whole House <br />-- - <br />-- --- <br />First Floor <br />Living Room <br />Dining Room <br />Kitchen <br />Laundry <br />MASTER <br />M/BA TH <br />Bathroom <br />BED2 <br />BED3 <br /> <br />26,488 <br />--.- <br />26,490 <br />5,199 <br />2,056 <br />2,514 <br />5,993 <br />4,331 <br />1,027 <br />1,027 <br />2,593 <br />1,750 <br /> <br />Whole House <br /> <br />26,488 <br /> <br />5,961 <br />--~ -- <br />5,962 <br />940 <br />710 <br />422 <br />1 ,440 <br />950 <br />160 <br />160 <br />710 <br />470 <br /> <br />5,961 <br /> <br />32,449 <br />- ------------ <br />32,452 <br />6,139 <br />2,766 <br />2,936 <br />7,433 <br />5,281 <br />1,187 <br />1,187 <br />3,303 <br />2,220 <br /> <br />32,449 <br /> <br />Total <br />Heat Loss <br />(BTUH) <br /> <br />32,903 <br />32,903 <br />5,715 <br />3,480 <br />1,955 <br />8,127 <br />5,373 <br />1,207 <br />1,207 <br />3,519 <br />2,320 <br /> <br />32,903 <br /> <br />--.,.,._---'---,._-._--.~---_._--_._-_._----~----------------------------..------...------ <br /> <br />HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. <br />Load calculations are estimates only, actual loads may vary due to weather and construction differences. <br /> <br />888 736-1101 <br /> <br />-- --------._-----.- -- _._-_.._----,._._---_._---._~--- -----,..-----.,----- - -- <br />