<br />... <br /> <br />Florida Design Solutions, Inc. <br />Structural Engineers <br />951 S. Orange Blossom Trail Apopka, FL 32703 <br />Telephone 407-814-2125 Facsimile 407-880-2309 <br /> <br />December 2, 2005 <br /> <br />City of Zephyrhills <br />County of Pasco <br /> <br />Ref: <br />Model: <br />Lot # <br />Address: <br />Subdivision: <br /> <br />US Home - Tampa <br />Walden Grande 2003 <br />82 <br />7616 Weehawken Drive <br />Crestview Hills <br /> <br />US Home job # <br />MKDA job# <br />FDS# <br />Permit# <br /> <br />15117-52-0090 <br />05-1459 <br />200508899 <br />4417 <br /> <br />Dear Elissa, <br /> <br />Based upon a telephone conversation with John Greene of US Home on 12/1/2005, we have <br />reviewed the above referenced plans due to an as-built condition, <br /> <br />The contractor installed a (2) 2XlO w/ Yz" flitch header between the foyer and bath #2 in lieu of <br />the (2) 2X12 header called for in the plans, <br /> <br />Based upon our structural review, we certify that this as-built condition is adequate and <br />acceptable for the design loads of this project, <br /> <br />If you have any further questions, please do not hesitate to call. <br /> <br />Sincerely, <br /> <br />,~1 ,1,) ~)" <br /> <br />f#? <br /> <br />~ (7~ r- <br />Car! A. Brown, P.E. <br />FL. # 56126 <br />12/2/2005 <br /> <br />Michael J, Burden, P.E, <br />FL. # 61628 <br />12/2/2005 <br />