Laserfiche WebLink
<br />, . <br /> <br />~ . <br /> <br />. . WINTER POINT MULTIPLIERS (WPM) <br />6A-10 WINTER OVERHANG FACTORS (WOF) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />~r <br />wa: <br />iilo Southwest 1.00 1.002 1.013 1.038 1.071 1.118 1.168 1.225 1.278 1.388 1.490 1.573 <br />Wl Wesl 1.00 0.999 1.003 1.013 1.025 1.040 1.053 1.067 1.077 1.095 1.107 1.116 <br />Northwest 1.00 0.999 0.998 0.997 0.997 0.996 0.995 0.994 0.993 0.992 0.990 0.989 <br />OH Len th 0.0' 1.0' 1.5' 2.0' 3.0' 3.5' 4.5' 5.5' 6.5' 9.5' 14.0' 2D.O' <br /> <br /> <br />6A-l1 WALL WINTER POINT MULTIPLIERS (WPM) <br /> FRAME CONCRETE BLOCK (NORMALYfn FACE BRICK LOG <br /> INTERIOR 00. R.VALUE WOOD FR R-VALUE BLOCK <br /> WOOD STEEL INSULATION INSUL 0-6.9 7.0 0-2.9 3.7 6 INCH 8 INCH <br />R-VALUE EXT ADJ 00 ADJ R-VALUE EXT ADJ EXT 7-10.9 2.1 3-6.9 2.6 R-VALUE EXT EXT <br />0-6.9 6.8 5.3 9A 6.7 0-2.9 6.0 3.1 6.0 11-18.9 1.7 7-9.9 1.8 0-2.9 2.2 1.2 <br />7-10.9 2.5 2.1 4A 3.3 3-4.9 3.8 2.3 2.8 19-25.9 1.0 10&UP 1.3 3-6.9 1.2 .9 <br />11-12.9 2.0 1.8 3.3 2.6 5-6.9 2.9 1.9 2.0 26&Up .6 7 & Up .9 .7 <br />13-18.9 1.8 1.6 3.0 2.4 7-10.9 2.3 1.5 1.5 <br />19-25.9 1.1 1.0 2.6 2.2 11-18.9 1.5 1.1 .8 <br />26& Uo .7 .7 1.4 1.2 19-25.9 .8 .7 I NOTE:SEE SECTION 2.0 OF APPENDIX C FOR MUL TIP'. ::RS I <br /> 26&Uo .5 .5 OF ENVELOPE COMPONENTS NOT ON THIS FORM. <br /> <br />6A-12 DOOR WINTER POINT MULTIPLIERS (WPM) 6A.13 CEILING WINTER POINT MULTIPLIERS (WPM) <br />DOOR TYPE EXTERIOR ADJACENT UNDER A mc SINGLE ASSEMBLY CONCRETE DECK ROOF <br /> R-VALUE WPM R-VALUE WPM CEILING TYPE <br />WOOD 7.6 5.9 19-21.9 .87 10-10.9 1.02 R-VALUE EXPOSED DROPPED <br /> 22-25.9 .78 11-12.9 .96 10-13.9 1.16 1.05 <br />INSULATED 5.1 4.0 26-29.9 .69 13-18.9 .84 14-20.9 .83 .76 <br /> 30-37.9 .64 19-25.9 .62 21 & Up .54 .50 <br /> 38 & Uo .55 26-29.9 .50 <br /> RBS Credit 0.850 30 & Up .46 <br /> IRCC Credit 0.905 <br />6A-14 FLOOR WINTER POINT MULTIPLIERS (WPM) White Roof Credit 1.044 <br />SLAB-ON-GRADE RAISED POST OR PIER STEM WALL w! UNDER <br />EDGE INSULATION CONCRETE CONSmUCTION FLOOR INSULATION ADJACENT <br />R-VALUE WPM R-VALUE WPM R.VALUE WPM WPM WPM <br />0-2.9 2.5 0-2.9 4.0 0-6.9 2A9 1.8 5.3 <br />3-4.9 -1.7 3-4.9 1.8 7-10.9 0.78 .7 2.1 <br />5-6.9 -2.4 5-6.9 1.1 11-18.9 OA7 .5 1.8 <br />7 & Uo -2.7 7 & Uo .8 19& Uo 0.14 .3 1.0 <br /> <br />6A-15 INFIL TRA TlON & INTERNAL GAINS (WPM) 6A-17 DUCT MULTIPLIERS OM) SeeTobIe6-10forCodemlnlmums. <br />Air Infiltration 0.87 DUCT RETURN DUCTS In: <br />Internal Gains .1.15 SUPPLY DUCTS IN: R-Value Unconditioned AttiC! Attlcl Attic/ I COnditione<l <br />Infiltration/Internal Gains -0.28 SD8ce RBS IRCC White roof soace <br />(Combined) 4.2 1.107 1.098 1.100 1.102 1.092 <br /> Unconditioned Space 6. 1.0rB 1.072 1.074 1.0ro 1.068 <br /> .)6 1.056 1.057 1.058 11.02 <br />6A.16 AIR HANDLER MULTIPLIERS (WPMl__ . )7 1.067 --- --- 1.009 <br />Located in oaraoe 1.00 Attic/Radiant Barrier (RBS) 1.051 no --- 1.045 <br />Located in conditioned area 0.92 1.041 --- no 1. 136 <br />Located on exterior of building 1.09 --- r088 --- 1. 177 <br />Located in attic 1.11 Attic/Interior Radiation 1.0 -- 1.066 --- If <br /> Control Coatinas (IRCG) 1.05r --- 1.052 --- <br /> 1.120 --- --- 1.110 <br /> Attic/White roof 1.0 ~ --- --- T. 11 <br /> 1. ~ --- no ", <br /> '. 1.l 1. 106 rOl0 1. <br /> Conditioned Space o:lT 1.l 1. OB 1.007 1. JUO <br />6A-18 HEATING SYSTEM MULTIPLIERS (HSMl 8.0 1.{ 1. 105 1.006 1.000 <br />SYSTEM TYPE See Tables 6-6 to 6-8 for code minimums HEATING SYSTEM MULTIPLIERS (HSM <br />Central Heat HSPF 6.40-6.79 6.80-6.89 6.90-7.39 7.40-7.89 7.90-8.39 8.40-8.89 8.9-9.39 9A-9.89 <br />Pump Units HSM .53 .50 A9 .46 .43 AI .38 .36 <br /> HSPF 9.90-10.39 1 OAO-l 0.89 10.90-11.39 11.40-11.89 11.90-12.39 12.40 & uo <br /> HSM .34 .33 .31 .30 .29 .28 <br />PTHP COP 2.50-2.69 2.70-2.89 2.90-3.09 3.10-3.29 3.30-3.49 3.50-3.69 3.70-3.89 3.90-4.19 <br /> HSM AO .37 .34 .32 .30 .29 .27 .26 <br />Electric Strip & Gas 1.0 (for gas credit multipliers, see Table 6A-21) <br /> <br />Effective date: March 1,2003 <br />