Laserfiche WebLink
<br />'. <br /> <br />.ADDITIONAl TABLES <br /> <br />CLIMATE ZONES.. 4 5 ~. <br /> <br /> <br />6A.2Q AIR DISTRIBUTION SYSTEM CREDIT MULTIPLIERS <br />PE CREDIT Prescriptive requirements Multiplier <br />Airtight Duct credit 610.1 A 1 1.00 <br />Facto -sealed AHU credi 610.2.A.2,1 0.95 <br />lDuct Sealing Multiplier (DSM) shall be 1.15 (summer) or 1.16 (winter) unless Airtight Duct credit ;s <br />demonstrated by test report. <br />2Muftiply Factory-sealed AHU credit by summer (Table 6A-7) or winter (Table 6A-16) AHU multiplier. <br />Insert tolal in the 'AS-Built AHU. box on page 2 or 4. <br /> <br />6A.21 HEATING CREDIT MULTIPLIERS (HCM) <br /> <br />::JT::JICM rt'c -(HeM) <br />Programmable Thermostat HCM .95 <br />Multizone HCM .95 <br />Natural Gas AFUE .68-.72 I .73-.77 I .78-.82 I .83-.87 I .88-.92 I .93 & UP <br />HCM .61 I .56 I .53 I .50 I .47 I .44 <br />LP Gas HCM .77 I .72 I .67 I .63 I .60 I .57 <br /> <br />6A.22 HOT WATER MULTIPLIERS (HWM) <br />SYSTEM TYPE See Table 6-12 for Code minimums HOT WATER MULTIPLIERS (HWM\ <br />Electric Resistance EF .80-.81 .82-.83 .84-.85 .86-.87 .88-.90 .91-.93 .94-.96 .97 & Uo <br />HWM 2820 2752 2685 2624 2564 2479 2400 2326 <br />Natural Gas EF .43-.47 .48- .49 .50-.51 .52-.53 .54-.55 .56-.57 .58- .59 .60-.61 .62-.63 .64-.65 .66 & Uo <br />HWM 2162 1936 1859 1787 1721 1660 1602 1549 1499 1452 1408 <br />LP Gas HWM 2645 2368 2274 2186 2106 2031 1960 1895 1834 1776 1722 <br />Ded. HP or Solar EF 1.0-1.49 1.5-1. 99 2.0-2.49 2.5-2.99 3.0-3.49 3.5-3.99 4.0-4.49 4.5-4.99 5.o-Uo <br />System with Tank HWM 2256 1504 1128 902 752 645 564 501 451 <br /> <br />6A.23 HOT WATER CREDIT MULTIPLIERS tHWCMl <br /> SYSTEM TYPE HOT WATER CREDIT MULTIPLIERS (HWCM\ -.--- <br />Heat Recovery Unit With Air Conditioner Heat Pumo -- <br />HWCM .84 .78 <br />Ml-on Dedicated Heat Pump EF 2.0-2.49 2.5-2.99 3.0-3.49 I 3.5 & Uo <br />(without tank) HWCM .44 .35 .29 I .25 <br />Add-on Solar Water Heater EF 1.0-1.9 2.0-2.9 3.0-3.9 I 4.0-4.9 I 5.0 & Uo __ <br />(without tank) HWCM .84 .42 .28 I 21 I .17 <br /> <br />NOTE: A HWM must be used in conjune#on with all HWGM. See Table 6A-22. EF Means Energy Factor. <br /> <br />6A.24 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 606.1.ABC.1.1 Max: .3 elmlsq.ft. window area; .5 cfmIsq.ft. door area. <br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> penetrations; between wall panels & toplbottom plates; between walls & floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from, and is sealed to, the foundation to the too olate. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings> 1/8. sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the perimeter, penetrations and seams. <br />Ceilings 606.1.ABC.1.2.3 Seal: Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the perimeter, at penetrations and seams. <br />Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 112" clearance & 3. from insulation; or Type IC rated with <2.0 elm from <br /> conditioned soace tested. <br />Multi-story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. <br />Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFP A, <br /> have combustion air. <br /> <br />6A.25 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.l <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (aasl must be orovided. External or built-in heat trao reouired for vertical oioe risers. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa <br /> & pool heaters must have a minimum thermal efficiency of 78%. <br />Shower Heads 612.1 Water flow must be restricted to no more than 2.5 aallons oar minute at 80 PSIG. <br />Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 minimum <br /> insulation. <br />HVAC Controls 607.1 Seoarate readily accessible manual or automatic thermostat for each system. <br />Insulation 604.1, 602.1 Ceilinas-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceilina & floors R-11. <br /> <br />Effective dale: March 1. 2003 <br />