<br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br /> CHAPTER 4 - Commercial Building Compliance Methods
<br />FORM 4000-01
<br />Renovations & Systems Prescriptive Method ALL CLIMATE ZONES
<br />Project Name: Zone: N
<br />Address: Building Classification:
<br />City. Zip Code: Building Permit No,:
<br />Builder: Permitting Office:
<br />Owner: Jurisdiction No,:
<br />
<br /> BUILDING INFORMATION
<br />WALLS ROOF/CEILING FLOORS DOORS GLASS
<br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE IU AR,EA TYPE U AREA
<br />Concrete (CBS J:l ,'t"ul Under Allie i,r>,> ~'__J Slab-on-nrade I!!> "''',,''' Wood ,:,f-<.. . 0 Sinnle wall ,..., 1'1 (.",
<br />Wood frame Sinole Assemblv Raised Wood Metal Double wall
<br />Metal frame ~ ~(C.t\ Other: Raised Concrete Insulated Sinole roof
<br />Insu atlOn H-va ue nsu ation R-va ue nsulation R,value Other I Double, roof
<br />
<br /> SYSTEMS INFORMATION
<br /> AIR CONDITIONER HEATING SYSTEM HOT WATER
<br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTU/H TYPE
<br />Unitary & Heat Pump ~ Central & Heat Pump Electric
<br /><65,000 Btulh ~ SEER <65,000 Btuth _ HSPF t"tl'l>l Resistance II
<br />~5,OOO BtuIh _EER _IPLV - ~5,OOO Btuth ---L COP Dedicated Heat Pump 0
<br />Water cooled _EER _IPLV - Water cooled _COP - Gas
<br />Evaporatively cooled _EER - Evaporat!+,ly cooled _COP - Natural 0
<br />PTAC _EER - Electric R.stance _COP - LPG 0
<br />Chiller _COP _IPLV - Gas/Oil (cir'cle one) HRU 0
<br />Gas heat pump _COP - <225,000/300,000 Btuth _AFUE - Other: 0
<br />Other: >225,0001300,000 Btulh Et
<br />LIGHTING Total Lighting Wattage 33 t;<{ /;)..~ I SIZING CALCULATION I DUCTS R-value t-..
<br />Total Conditioned Floor Area .l.16() Watts/sq,ft, (II required) 0 Location 0 L>l4'
<br />Attached
<br />
<br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.)
<br />Components SecUon Reaulrements Check
<br />Operations Manual 102.1 Ooerations manual will be orovided to owner. ~
<br />Windows 406,1 Maximum of ,3 cfm Der sq,ft, of window area, It
<br />Doors 406,1 Maximum of 1,2 dm eer so~ft, of door area, II
<br />Joints/Cracks 406,1 To be caulked, oasketed, weatherstriDped or otherwise sealed, "-
<br />Reheat 407,1 Electric resistance reheat Drohibited, A/'tII
<br />Ventilation 409,1 Supplied with readily accessible switch for shut-oH andlor volume reduction when ventilation is not required, X
<br />HV AC EHiciencv 407,1,408.1 Minimum eHiciencies_ Heating: Tables 4-7, 4-8, 4,9, Cooling: Tables 4-3, 4-4, 4-5, 4-6, )I..
<br />HV AC Controls 407,1 Separate readily accessible manual or automatic thermostat for each system, ~
<br />HV AC Ducts 410,1 Air ducts, fillings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated l'
<br /> and installed in accordance with the criteria of section 410,1 ,
<br />Balancing 410,1 HVAC distribution system(s) tested and balanced, X
<br />Piping Insulation 411.1 In accordance with Table 4-11, };
<br />Water Heaters 412,1 Automatic electric storage water heaters $120 gallons and gas & oil fired storage water heaters $75,000 Btulh shall meet
<br /> performance requirements in Table 4-12, Electric >120 gallons: standby loss $.'~)+27NT' Gas >75,000, Oil >105.000: E, ,78, "-
<br /> Standby loss < 1,30+114N,. Gas, Oil >155,000: E,,78, Standby loss < 1,30+95/VT,
<br />Swimming Pools 412,1 Spas & heated pools must have covers, Non-commercial pools must have pump timer, Gas spa & pool heaters must ).)c:t
<br />& Spas have a minimum thermal eHiciency of 78%,
<br />Hot Water Pipe 412,1 Piping heat loss is limited to the levels in Table 4,11 for circulating systems and the first 8' of pipe from a storage #11
<br />Insulation tank,
<br />Water Fixtures 412,1 Shower head water flow restricted to maximum of 2,5 gpm at80 psi, Toilets meet 42CFR 6295(k), Public lavatory fixture '"
<br /> maximum flow of .5 gpm; or if self-closing valve, .25 gallon circulating, ,5 gallon non-circulating,
<br />Lighting 415,1 Ballasts shall have Power Factors no less than ,90, y
<br />
<br />If required by Florida law, I hereby certify that the system design is in compliance with the Florida Energy Code,
<br />ARCHITECT:
<br />ELECTRICAL SYSTEM DESIGNER:
<br />LIGHTING SYSTEM DESIGNER:
<br />MECHANICAL SYSTEM DESIGNER:
<br />PLUMBING SYSTE ESIGNER:
<br />
<br />Registration No,
<br />
<br />
<br />PREPARED BY:
<br />I hereby certify lhal1l1'
<br />
<br />OWNER AGENT:
<br />
<br />ifications covered by the calculalion are in compliance with the
<br />
<br />It ~-.!J,:J!. ('
<br />il-l~
<br />
<br />Review or plans and specifications covered by this calculation indicates compliance with
<br />the Florida Energy Code. Before conSlructton ts compIeled, this building wjll be inspected
<br />for compliance in accordance with Section 553.908, F.S.