<br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br /> CHAPTER 4 - Commercial Building Compliance Methods
<br />FORM 4000-01
<br />Renovations & Systems Prescriptive Method ALL CLIMATE ZONES
<br />Project Name: " Zone: /I.
<br />Address: . Building Classification:
<br />City. Zip Code: Building Permit No.:
<br />Builder: Permitting Office:
<br />Owner: Jurisdiction No,:
<br />
<br /> BUILDING INFORMATION
<br />WALLS ROOF/CEILING FLOORS DOORS GLASS
<br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AR.,EA TYPE U .AREA
<br />Concrete CBSl }~ H'",,(T Under Allie to" .., '~~j SIab-on-orade t!> """"1'\ Wood lLl. Sinole wall ,.;;.t I'i' <0 -
<br />Wood frame Sinale Assemblv Raised Wood Metal :-r~ ~ 0 Double wall
<br />Metal frame :~ S'<;'-6 Other: Raised Concrete Insulated I Simile roof
<br />nsu allan R,value Insulation R-value Insulation R-value Other I Double, roof
<br />
<br /> SYSTEMS INFORMATION
<br /> AIR CONDITIONER HEATING SYSTEM HOT WATER
<br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUlH TYPE
<br />Unitary & Heat Pump ~ Central & Heat Pump Electric
<br /><65,000 Blulh ~ SEER <65,000 Btu/h _ HSPF I..(Oc>(; Resistance KJ
<br />~5,OOO BIuIh _EER _'PLV - ~5,000 Btuth -L COP Dedicated Heat Pump 0
<br />Water cooled _EER _'PLV - Water cooled _COP - Gas
<br />Evaporativefy cooled _EER - Evapora~;+'ly cooled _COP - Natural 0
<br />PTAC _EER - Electric R.stance _COP - LPG 0
<br />Chiller _COP _'PLV - Gas/Oil (cir'cle one) HRU 0
<br />Gas heat pump _COP - <225,000/300,000 Btuth _ AFUE - Other: 0
<br />Other:__ - - - ~25,000I3oo,OOO Btuth _E, -
<br />LIGHTING Total Lighting Wallage 3~ <;y t I ).. '-I I SIZING CALCULATION I DUCTS R-value '"
<br /> = = (If required)
<br />Total Conditioned Floor Area l:l 6 t) Walls/sq,ft, Attached 0 Location V Loa:,.
<br />
<br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by al/ buildings,)
<br />Components Section RequIrements Check
<br />Ooerations Manual 102,1 Operations manual will be provided to owner, ~-
<br />Windows 406,1 Maximum of ,3 elm per sq.ft, of window area, lC
<br />Doors 406,1 Maximum of 1,2 cfm per sq,ft, of door area, ')c..
<br />Joints/Cracks 406,1 To be caulked, gasketed, weatherstripped or otherwise sealed, ^
<br />Reheat 407.1 Electric resistance reheat prohibited, "vjf
<br />Ventilation 409.1 Supplied with readily aCcessible switch for shut'off and/or volume reduction when ventilation is not required, X
<br />HV AC Efficiencv 407,1, 40S.1 Minimum efficienci!lS~ Heating: Tables 4-7, 4-S, 4-9, Cooling: Tables 4-3, 4-4, 4-5, 4-6, ,r;:
<br />HV AC Controls 407,1 Separate readily accessible manual or automatic thermostat for each system, P\...
<br />HV AC Ducts 410,1 Air ducts, fillings, mechanical equipment and plenum chambers shall be mechanically allached, sealed, insulated
<br /> and installed in accordance with th!l criteria of Section 410,1, "-
<br />Balancing 410,1 HVAC distribution syst!lm(s) test!ld and balanced, X
<br />Piping Insulation 411,1 'In accordance with Table 4-11, "-
<br />Wat!lr H!lalers 412,1 Automatic electric storage water heaters :5120 gallons and gas & oil fir!ld storag!l wat!lr heat!lrs :575,000 Btuth shall m!let
<br /> performance rElquirElments in Table 4-12, Electric> 120 gallons: standby loss :5,~27 NT, Gas >75,000, Oil > 1 05,000: E, ,78, "'-
<br /> Standby 10ss:5 1,30+114NT, Gas, Oil >155,000: E.,7S, Standby 10ss:5 1.30+951VT,
<br />Swimming Pools 412,1 Spas & heated pOOls must have covers, Non-commercial pOOls must have pump timer, Gas spa & pool heat!lrs must )I :.t
<br />& Spas hav!l a minimum thermal !lfficiency of 7S%,
<br />Hot Water Pipe 412,1 Piping heat loss is limited to lh!l l!lvels in Table 4-11 for circulating syst!lms and the firstS' of pipe from a storage #7?
<br />Insulation tank,
<br />Water Fixtures 412,1 Shower head waler flow restricted to maximum of 2,5 gpm at 80 psi, Toil!lts meet 42CFR 6295(k), Public lavatory fixture j..
<br /> maximum flow of .5 gpm; or if self'c/osing valve, ,25 gallon circulating, ,5 gallon non-circulating.
<br />Lighting 415,1 Ballasts shall have Power Factors no less than .90, ~
<br />
<br />If required by Florida law, I hereby certify that the system design is in compliance with the Florida Energy Code,
<br />ARCHITECT:
<br />ELECTRICAl SYSTEM DESIGNER:
<br />LIGHTING SYSTEM DESIGNER:
<br />MECHANICAL SYSTEM DESIGNER:
<br />PLUMBING SYSTE ESIGNER:
<br />
<br />Registration No.
<br />
<br />
<br />PREPARED BY:
<br />I hereby certify Ihat 1his
<br />
<br />OWNER AGENT<..;,
<br />
<br />iffcations covered by the calculation are in compliance with the
<br />
<br />DATE: (f- tl-'? r
<br />ne Cpde,
<br />- Lr DATE II- 0::/-a-
<br />
<br />Review of plans and specificalions covered by this calculation indicates compliance with
<br />Ihe Aorida Energy COde, Before construction is completed, this building will be inspected
<br />for compliance in accordance wi'h Section 553,906, F.S,