Laserfiche WebLink
<br />05-30324.05 <br />Page 4 of 8 <br /> <br />Test Specimen Description: (Continued) <br /> <br />Drainage: <br /> <br />Description <br /> <br />Quantity <br /> <br />Location <br /> <br />7/8" wide by 3/16" <br />high weepslot <br /> <br />2 <br /> <br />One 2-1/4" from each end of the <br />exterior sill face (with flaps), one at <br />each end of the center sill wall <br /> <br />3/4" wide by 3/16" <br />high weepslot <br /> <br />2 <br /> <br />Sill screen track, one at each end <br /> <br />1-1/4" wide by 1/2" <br />deep weepslot <br /> <br />2 <br /> <br />Sill, one at each end of the interior <br />jamb track <br /> <br />3/8" wide by 1/8" <br />deep weepslot <br /> <br />4 <br /> <br />Bottom sash rail and exterior <br />meeting rail, one at each end <br /> <br />Reinforcement: The lock rail contained a rectangular shaped, formed steel reinforcement <br />measuring 0.649" x 0.461" x 0.047" (reference drawing #2707). The exterior meeting rail <br />and sash stiles contained a "U" shaped steel reinforcement measuring 0.781" x 0.400" <br />x 0.047" (reference drawing # 2709). <br /> <br />Installation: The unit was installed in a wood buck constructed of Spruce-Pine-Fir <br />construction lumber and sealed at the exterior perimeter with a silicone sealant. A 3/4" x <br />3/4" wood stop was applied to the interior and exterior perimeter and secured with 2" <br />drywall screws spaced approximately 16" on center. <br />