Laserfiche WebLink
<br />05-30324.05 <br />Page6of8 <br /> <br />Test Results: <br /> <br />Paragraph <br /> <br />Title of Test - Test Method <br /> <br />Results <br /> <br />Allowed <br /> <br />Test Specimen #1: H-LC30 48 x 78 (Continued) <br /> <br />2.1.7 <br /> <br />Welded Comer Test <br /> <br />Meets as stated <br /> <br />Meets as stated <br /> <br />2.1.8 <br /> <br />Forced Entry Resistance per AAMA 1302.5-76 <br />Tests A through G No entry <br /> <br />No entry <br /> <br />Optional Performance <br /> <br />4.3 <br /> <br />Water Resistance per ASTM E 547-00 <br />(with and without screen) <br />WTP = 9.0 psf No leakage <br /> <br />No leakage <br /> <br />4.4.2 Uniform Load Structural per ASTM E 330-97 <br />(Measurements reported were taken on the exterior meeting rail) <br />@ 45.0 psf (positive) 0.04" 0.179" max. <br />@45.0psf(negative) 0.06" 0.179"max. <br /> <br />Test Specimen #2: H-LC35 44 x 77 <br /> <br />Optional Performance: <br /> <br />4.4.1 <br /> <br />Uniform Load Deflection per ASTM E 330-97 <br />(Measurements reported were taken on the exterior meeting rail) <br />@ 35.0 psf (positive) 0.44" See Note #2 <br />@ 35.0 psf(negative) 0.46" See Note #2 <br /> <br />Note #2: The Uniform Load Deflection test is not an AAMAINWWDA 101/18.2-97 <br />requirement for this product designation. The data in this report is for information only. <br /> <br />4.4.2 Uniform Load Structural per ASTM E 330-97 <br />(Measurements reported were taken on the exterior meeting rail) <br />@ 52.5 psf(positive) 0.03" 0.163" max. <br />@ 52.5 psf(negative) 0.03" 0.163" max. <br />