Laserfiche WebLink
<br />F <br /> <br />, <br /> <br />) <br /> <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> CHAPTER 4 - Commercial Building Compliance Methods <br />FORM 4000-01 <br />Renovations & Systems Prescriptive Method ALL CLIMATE ZONES <br />Project Name: Zone: '"* <br />Address: Building Classification: <br />City. Zip Code: Building Permit No.: <br />Builder: Permitting Office: <br />owner: Jurisdiction No.: <br /> <br /> BUILDING INFORMATION <br />WALLS ROOF/CEILING FLOORS DOORS GLASS <br />TYPE U ARFA, TYPE U AREA TYPE U AREA TYPE U AREA TYPE U ARE~,._ <br />Concrete CBS) .~ l:L7~ Under Attic .. Slab-on-arade 'J ::l'1- SV Wood Sinale wall .M J. f\t. <br />_.& oJ';'.,. Sinale Assemblv Raised Wood Metal I."e '1~ Double wall .~ <br />Wood frame <br />Metal frame Other: Raised Concrete Insulated ~ S inate roof <br />Insulation A-value Insulation R-value Insulation A-value Other Double, roof <br /> <br /> SYSTEMS INFORMATION <br /> AIR CONDITIONER HEATING SYSTEM HOT WATER <br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTutH TYPE <br />Unitary & Heat Pump ~ Central & Heat Pump Electric <br /><65.000 Btuth ~ SEER <65,000 BtuJh _ HSPF (f 1>0 <> Resistance ~ <br />265,000 Btu/h _EER _IPlV - 265,000 Btuth -'- COP Dedicated Heat Pump 0 <br />Water cooled _EER _IPlV - Water cooled _COP - Gas <br />Evaporatively cooled _EER - Evaporatively cooled _COP - Natural 0 <br />PTAC _EER - Electric Resistance _COP - lPG 0 <br />Chiller _COP _IPlV - Gas/Oil (circle one) HRU 0 <br />Gas heat pump _COP - <225,000/300,000 Btulh _ AFUE - Other: 0 <br />Other: >225,000/300,000 Btuth E, <br />LIGHTING Total lightJng Wattage L.iL t)O J'fs't I SIZING CALCULATION I DUCTS R-value 'A <br /> - (II required) D t;I ~(!-t' <br />Total Conditioned Floor Area ~~\-O Watts/sq.ft. Attached location <br /> <br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.) <br />Components Section Requirements Check <br />Ooerations Manual 102.1 Operations manual will be provided to owner. y <br />Windows 406.1 Maximum of .3 cfm per sq.ft. of window area. ~ <br />Doors 406.1 Maximum of 1.2 elm per sq. ft. of door area. V <br />Joints/Cracks 406.1 To be caulked, gasketed, weatherstripped or otherwise sealed. )0. <br />Reheat 407.1 Electric resistance reheat prohibited. ."..., <br />Ventilation 409.1 Supplied with readily accessible switch for shut-oil andlor volume reduction when ventilation is not required. <br />HVAC Elliciencv 407.1, 408.1 Minimum eHiciencies - Heating: Tables 4-7, 4-8, 4-9. Cooling: Tables 4-3. 4-4, 4-5. 4-6. <br />HVAC Controls 407.1 Separate readily accessible manual or automatic thermostat for each system. <br />HV AC Ducts 410.1 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated <br /> and installed in accordance with the criteria of section 410.1. 'f'-. <br />Balancing 410.1 HV AC distribution system(s} tested and balanced. ,11 <br />Piping Insulation 411.1 In accordance with Table 4-11. ~ <br />Water Heaters 412.' Automatic electric storage water heaters $120 gallons and gas & oil fired storage water heaters 95.000 Btulh shall meet ^ <br /> performance requirements in Table 4-12. Electric> 120 gallons: standby loss S.30+27N,. Gas >75,000, Oil > 105.000: E, .78, <br /> Standby loss < 1.30+114N,. Gas. Oil >155,000: E,.7B, Standby loss < 1.30+95N,. <br />Swimming Pools 412.1 Spas & heated pools must have covers. Non-commercial pOOls must have pump timer. Gas spa & pool heaters must /tit? <br />& Spas have a minimum thermal eHiciency of 78%. <br />Hot Water Pipe 412.1 Piping heal loss is limited to the levels in Table 4-11 for circulating systems and the first 8' of pipe from a storage "'- <br />Insulation tank. <br />Water Fixtures 412.1 Shower head water flow restricted to maximum of 2.5 gpm at 80 psi. Toilets meel 42CFR 6295(k). Public lavatory fixture JIll <br /> maximum flow of .5 gpm; or if self-closing valve, .25 gallon circulating, .5 gallon non-circulating. <br />Lighting 415.1 Ballasts shall have Power Factors no less than .90. l <br /> <br />If required by Florida law. I hereby certify that the system design is in compliance with the Florida Energy Code. <br /> <br />ARCHITECT: <br />ELECTRICAL SYSTEM DESIGNER: <br />LIGHTING SYSTEM DESIGNER: <br /> <br />MECHANICAL SYSTEM DESIGNER: <br /> <br />PLUMBING SYSTE ESIGNER: <br /> <br />I hereby certify that pecifK:alions covered by the calculation are in compliance with the <br />Florida EnergyC ~~ <br /> <br />PREPARED BY: _ _ . _ .._ _. _... DATE: r :../'1-Of <br />I hereby certily that this building. in compli e wilh Florida Energy Code <br /> <br />Registration-No. <br /> <br />Review of plans and specifications covered by this caJculalion indicates compliance wilh <br />Ihe Ronda Energy Code. Belore construction is completed. this building win be inspected <br />for compliance in accordance with Section 553.908, F.S. <br /> <br />FLORIDA BUILDING CODE - BUILDING <br /> <br />13.175 <br /> <br />, <br /> <br /> <br /> <br /> <br />nJ <br /> <br />BUILDING OFFICIAL: <br /> <br />OWNER AGENT: ___._____. <br /> <br />DATE: <br /> <br />DATE: <br />