<br />:Cf: 0905297 <br /> <br /> <br />21_9~" <br /> <br />l <br /> <br />7 5/8" - <br />CHANNEL LETTER <br /> <br />I <br /> <br />REFERENCE <br />FRONT <br />ELEVATION <br /> <br />L <br /> <br />. <br /> <br />FRONT ELEVATION <br /> <br /> <br />SECTION DETAIL <br />N.T.S. <br /> <br />~FASTENER LOCATION(1YP) <br />(MINIMUM QUANTI1Y INDICATED, <br />4 PER CABINET) <br /> <br />EXISTING WALL(CMU OR SOLID CONCRETE) <br />(RESPONSIBILl1Y OF OTHERS) <br /> <br />1/4"0 TAPCON MASONRY FASTENERS <br />(I 1/4" MINIMUM EMBEDMENT IN CONCRETE) <br />(REFERENCE FRONT ELEVATION <br />FOR MINIMUM QUANTI1Y) <br /> <br />NOTES: <br /> <br />I. <br /> <br />THE DESIGN, FABRICATION AND CONSTRUCTION SHALL CONFORM TO THE FOLLOWING CODES <br />AND SPECIFICATIONS: THE 2004 FLORIDA BUILDING CODE, THE AMERICAN <br />INSTITUTE OF STEEL CONSTRUCTION(MANUAL OF STEEL CONSTRUCTION(9TH EDITION), THI <br />AMERICAN WELDING SOCIETY(AWS 01.1-98), THE AMERICAN CONCRETE INSTITUTE BUILDINC <br />CODE REQUIREMENTS FOR STRUCTURAL CONCRETE(ACI :518-95), THE SPECIFICATIONS FOR <br />ALUMINUM STRUCTURES BY THE ALUMINUM ASSOCIATION(CURRENT EDITION), <br /> <br />2, <br /> <br />STRUCTURAL STEEL REQUIREMENTS: PLATES, ROLLED SHAPES AND BARS SHALL <br />BE ASTM M6(OR EQUAL), STANDARD PIPE SHALL BE ASTM A5:5, GRADE B(OR BETTER, <br />FY=:55 ~SI), STRUCTURAL TUBING SHALL BE ASTM A500, GRADE B(OR BETTER, FY= 46 <br />~SI), ALL BOLTED CONNECTIONS SHALL BE MADE WITH ASTM A:525 BOL TS(OR BETTER <br />WITH FLAT WASHERS(UNLESS NOTED OTHERWISE), ALL FASTENERS TO BE NON-CORROSIVE, <br />ALL STRUCTURAL STEEL SHALL BE SHOP PRIME COATED WITH A RUST INHIBITIVE PRIMER <br />AND FINISH PAINTED AS APPROVED BY OWNER(SURFACE PREPARATION SHALL BE IN <br />ACCORDANCE WITH THE MAUUFACTURER'S RECOMMENDATIONS), FIELD CONNECTIONS AND <br />DAMAGED OR ABRADED AREAS OF PROTECTIVE COATING SHALL BE TOUCH UP PAINTED WITH <br />COMPATIABLE MATERIAL, ALL STEEL SUBJECT TO DIRECT CONTACT WITH EARTH SHALL <br />BE BITUMASTIC(OR EQUAL) COATED(IF NOT SUBJECT TO SUNLIGHT AND CARBOMASTIC(OR <br />EQUAL) COATED(IF SUBJECT TO SUNLIGHT) IN ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATIONS, ALL WELDS SHALL BE MADE WITH E70XX ELECTRODES(OR EQUAL), <br />ALL FIELD WELDS SHALL COMPLY WITH AWS CODE FOR PROCEDURES, APPEARANCE, <br />AND QUALITY OF WELDS, ALL WELDERS AND WELDING PROCESSES SHALL BE QUALIFIED <br />IN ACCORDANCE WITH AWS STANDARD QUALIFICATION PROCEDURES. <br /> <br />:5, ALL FERROUS TO NONFERROUS SURFACES SHALL BE SEPARATED BY :5M#:555 POLYESTER <br />CLEAR TAPE(OR EQUAL), <br /> <br />4. THE ELECTRICAL INSTALLATION SHALL BE IN COMPLIANCE WITH THE NATIONAL ELECTRICAL <br />CODE AND ALL REQUIREMENTS OF THE LOCAL GOVERNING AUTHORITY, <br /> <br />5, THE DESIGN WIND SPEED IS 1:50 MPH PER ASCE 7-02 WITH .C. EXPOSURE RESULTING IN A <br />DESIGN PRESSURE OF :5:5,76 PSF AT A HEIGHT OF 20'-0. ABOVE GRADE, <br /> <br />6, THE CUSTOMER'S BUILDING ENGINEER IS TO DETERMINE IF THE BUILDING STRUCTURE WilL <br />SUPPORT THE SIGN, THE CUSTOMER SHALL SUPPLY ANY ADDITIONAL STRUCTURE REQUIRED, <br /> <br />7, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD AND <br />NOTIFY THE ENGINEER OF ANY DISCREPANCIES, WALL SECTION PER CUMMINGS SIGNS SURVE <br /> <br />8, ENGINEERING SEAL is APPLICABLE TO THE MOUNTING PLATE/WALL ATTACHMENT DESIGN ONL <br /> <br />9, ALL ELECTRICAL COMPONENTS ARE UL LISTED, SIGNAGE IS MANUFACTURED iN COMPLlANC! <br />NEC 600, SIGNAGE is GROUNDED IN COMPLIANCE WITH NEC 250, ONE ViSIBLE 20 AMP <br />DISCONNECT IS REQUIRED PER CIRCUIT, <br /> <br />10, INSTALL TAPCON FASTENERS IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN <br />INSTRUCTIONS AND RECOMMENDATIONS, <br /> <br />tlEVIEW DATE: ~ I.... . J 0(; b <br />CITVOFZEPHY~ ~, <br />IHHLDING OFFICIAI/!Itd ~ d--' <br /> <br />Glenn T. Tisdale, P,E. <br /> <br />CUMMINGS SIGNS, INC. <br />P.O. Box 23/94 <br />NASHVILLE, TN 37202 <br />CHANNEL LETTER SET <br />TACO BELL- 7:31:3 GALL BOUlEVARO- ZEPHYRHILLS, FL <br /> <br />~ T.s~~ <br /> <br />'df" <br /> <br />.; ""'- <br />designFirst, Inc. <br />p,o, BOX 9335 <br />DOTHAN, AL 36304 <br />(334)793,9734 <br /> <br />GT <br />1/2': I' <br />10/19/05 <br />I OF 1 <br />0905297S1 <br /> <br />CAD: <br />SCALE: <br />DATE: <br />SHT, NO,; <br />DWG, NO,: <br /> <br />- <br />\~ _(q ...65 <br />