Laserfiche WebLink
<br />GROUND ROO <br />(TYPI <br />FENCE BOND <br />CONDOC T OR <br /> <br />FENCE BOND - <br /> <br />@TYP <br /> <br />TE, T INSPECTiON <br />?IT (T'yp OF 21(2) <br /> <br />FENCE BONO _ X <br />COND~TOR <br />FENCE BONO - <br /> <br /> <br />X <br /> <br />FUTURE GENERA TOR <br />ON 5'XI2' CONe PA<Q <br /> <br />X <br /> <br />X <br /> <br />X <br /> <br />x <br /> <br />EXISTING T'MKJBILE <br />EQUIPMENT PA<Q WI <br />CABINETS <br /> <br />SERVICE CROUI\O COI\OVCTOIl <br />ll'2 AWO BARE, TINNED SOlID COPPl:R <br />INSTAlLED IN '" pve <br /> <br />~~ ~~T~RV1CE <br />SERvlCf: ENTRNlCE <br />GRCiU'<<l ROD <br /> <br />PROPOSED SHELTER CRO\JNO 17\ <br />R1NGI ll'2 AWG B~....,T~NED, \1; <br />SOlID CQP?(R CO",,^^- TOR <br /> <br />X <br /> <br />FE N<:E BONO CONDOC T OIl <br />ll'2 AWO BARE, TINNED, <br />SOliD COPPER <br />CONOVC T OR (TYP I <br /> <br />FEN<:E BONO I TYPI <br />SEE DET M. THIS $HEE T <br /> <br />GROUNDING PLAN <br />SCALE AS NOTED <br /> <br />~ <br /> <br />EXISTING VERIZON <br />ME TER ON <br />UTILITY POLE <br /> <br /> <br />EXISTING T-MOBlLE <br />METER AND DiSCONNECT ON <br />UTILITY POLE <br /> <br />~ <br /> <br />EXISTING BHlSOUTH <br />UTILITY POLE <br /> <br />FENCE POST <br /> <br /> <br />EXOTHERMIC WElD <br />COLD GAL V ANilE <br />AF TER COOLING <br /> <br />FINISHED GRADE <br /> <br />1'-0" <br />MAX IMUM <br /> <br />FENCE BONDING DETAIL <br />NOT TO SCAlE <br /> <br />F~ Z4".a" DR....IN(;1 <br />GRAPHIC SCALE. '/4" . "-0" <br /> <br />r~ ,,".17" DRAIINC1 <br />GRAPHIC SCALE. 1/&"' "-0" <br /> <br />---- <br /> <br />GENERAL GROUNDING NOTES <br /> <br />\. INSTN.L GROUND RING 2 FEET OUTSOE Of BUILDINO fOuNDA1iON AND ~O INCHES <br />BELOW GRADE ICOOROINATE WITH CONSTRUCTON MANAGER) GROUND RING <br />CONSISTS or ll'2 AWG SOliD BARE TINNED COPPER <br /> <br />INSTN.L GROUND RING BEFORE THE BUILDIN<: IS SET "'A<NT"N CONNECTIONS TO <br />THE BUILDING AND TCWER AT N.l TIMES <br /> <br />3. VERIfY EXiSTING FENCE BONO TO THE EXISTING TOWER EGR. PROVIDE FENCE <br />BONDING TO RING If NONE EXiSTS USE "2 ANC BARE, SOLID, TINNED COPPER <br />CONDUCTOR, EXOTHERMICALL Y WELDED TO UNDERCROUND RING. <br /> <br />4. EXOTHERMC WElD N.l CONNECTIONS TO BURIED GROUND RINO WITH TEE <br />WElDS, USE SHCRT RODS WHERE STANDARD GROUND RODS ARE NGT USED <br />SEE CABLE TO CABLE DETA<L. <br /> <br />5 CooRDINA1E WITH OWNER AND >EX TEL AN~ BONDING TO EXISTlNO EXTERNAl <br />GROUND RIN<: IEGR), fENCE. OR OTHER OWNER STRUCTURES OR EQUIPMENT. <br /> <br />MAKE N.l GR'OUNOING CONNECTIONS AS SHORT AS POSSIBLE MINIMUM BENDINO <br />RADIUS IS B" <br /> <br />CLEAN N.L SURF ACES AND BRUSH WITH BRONlE BRUSH PRIOR TO MAKING GROUND <br />CONNECTIONS P"NT ALL EXOTHERMIC WELDS TO GAlVANIZED OBJECTS WITH <br />GN.VANIZE PA<NT. USE NO-OX COMPOUND WiTH METN. TO METN. CONNECTIONS <br /> <br />PROVIDE A "2 AWG SOLID TINNED C'OPPER CONDUCTOR FROM THE SECTOR BUSS <br />BARs TO TOWER GROUND RINC lNOT SHeWN). EXOTHERMICAlL Y WElD AT EACH <br />EI\O. GROUND lEADS TO FOllOW COAXIAL CABLE DOWN TOWER <br /> <br />PROVIDE "2 AWG SOLID TINNED COPPER (MINIMUM JO" BrG) BONDING CONNECTION <br />TO 10WER GROUND RINO FROM SHElTER GROUND RINO <br /> <br />10 INSTN.L s.." , 10' COPPER CLAD GROUND RODS IN LOCATiONS SHOWN. DISTANCE <br />10'-0" MINiMUM TO 15'-0" MAXIMUt,l BETWEEN ROOS <br /> <br />I'. BONO ALL WAVE GUDE PeSTS TO RESPECT!VE GROUND RINO ITDWER/SHElTERI USE <br />"2 AWG BARE, TINNED COPPER USE EXOTHERMIC WElD FOR CONNECTIONS TO POSTS <br /> <br />12. BONO EXTERl'lAl HALO DROPS TO GROUND RODS USING EXOTHERMIC WElD <br />lONE AT EACH CORNER) IF .NEEDED, CONTRACTOR TO VERiFY. <br /> <br />13 BONO AlL FENCE POSTS WITHIN 6' or EOUIPMENT SHEL TER TO GROUND RING <br /> <br />14. N.L WAVGUIDE SECTIONS SHALL BE BONDED <br /> <br />15 GROUND RING MUST BE INSPECTED BY CONSTRUCTION MANACER PRIOR TO BACKFILL PROViDE <br />24 HOURS NOT<:;E <br /> <br /> <br />16 ~~~~ ~g ~~J~~~~ :bE %~s1[ (LO,.%~ o'u~"'t~FSi I~~ T ~O~ ~ A<~ 0 H~~~~\i' ~:~gE t ~ 1J"TEH~~1,c N.l Y <br /> <br />WElD CONNECTON TO GROUND RING. CONNECTON TO liFTING HOOK<S) SHN.l BE MADE AT THE <br />AXlE BAR WITH AN APPROVED CROUNOING ClA<MP <br /> <br />17. CONTRACTOR SHALl PLACE (2) TWO TEST INSPECTiON WElLS AT SHELTER GROVND RINC WHERE <br />ABlE, E TEST WEll SHAlL BE PlACED BEHIND THE SHElTER, AND ONE IN FRONT Of THE SHELTER <br />T SIDE or THE STOOP, WHEREVER SITE CONDITIONS PREVENT A TEST WElL FROM BEING PLACED <br />B THE SHElTER, A TEST WELl SHAlL BE PLACED AS ClOSE TO THE REAR OF THE SHElTER AS <br />POS E N.ONG THE SHORT WN.L TEST WEllS SHAll BE PLACED CLEAR OF ALL ICE BRIDGES .AND <br />OVERHANGING EQUIPMENT. <br /> <br />18, ROUTING OF CONDUIT, FEEDERS, AND lOCATION OF UNDERGROUND HARC'NARE ARE SHOWN FOR <br />CLARITY AND DIAGRAMMATIC PURPOSES O"t. Y. ACTUN. lOCATiON SHAlL BE ACCESSIBLE AND <br />AD,NSTED BASED ON FUD CONDITIONS <br /> <br />GROUNDING PlAN NOTES: <br />CD ~~~Et C~~~eL ~IN?XC'f~ A ftE(J~R'N~ m~'2fiO~R~gN~v~',~ Eig~i:~J~&RGROUND <br />S~STEMS WHICH MAY BE PRESENT COORDINATE ALl UNDERCROUND INSTAllATiON. <br />VERIFY SllE, LOCATION AND DEPTH OF EXISTING TOWER RING <br /> <br />CD ~G:,Wfo B~r f~}~9i,J~NNGE.?oJSrR~~Gcg~~~fd?,~:'ivWH TtxEo~~1t,l?fO:;~~D BAR <br /> <br />0) <br />o <br /> <br />@) <br />@ <br /> <br />(2) <br />@ <br />@ ~u~~~~~~~~ ~6THi~E T~ETE~~6~ T~~6H(il{ ~~H~~~E~PsTBR'(JT:~1c) <br /> <br />@ ~~~~',5~ W~~~EB8~6"'i6\~~RroVEG~o"U~lg<TR~ZG IN PROPOSED METER CENTER ON RACK. <br /> <br />@ NOT USED <br />@ WAVECUOE POST BONDINC "2 BARE, TINNED, SOliD COPPER I!rPlCAL N.L POSTS) <br />@ GROUND Kli CONNECTION TO COm.... CABLE GROUNO TO '~AV(GVlOE MO\JNT[Q GROUND BAR <br />@ CROUND GPS MKJVN T S TO GROUND RING <br />@ ~JMiO~N "t'touG:DOUR7& BAR, EXTEND "2 BARE, TINNED. SOLID COPPER CONDUCTOR TO SINGLE <br /> <br />101GB MOVN'[Q TO WAVE GUIDE DIRECTlY OPPOSITE MICROflECT PORT <br /> <br />PROVIDE GROUND KIT CONNECTION TO OVTER CONDVCTOR Of COAXlN. CABLE PRIOR <br />TO ENTRANCE TO EQUIPMENT SHElTER TYPICN. OF All CABLES <br /> <br />BEl 0 W GR ADE C ABl E TO C ABL E GROVND CONNE C TlON SEE DET A<L ON SHE ET E' <br /> <br />BONO MISCElLANEOUS METAL TO GROUND RINC IF CLOSER THAN 6'-0" TO RINC CONFIRM <br />WITH NEXTH CONSTRUCTiON M".-.AGER PRiOR TO CONNECTINO. <br /> <br />TEST/lNSPECTiON PIT. SEE DETA<l ON DRAWING E4 <br /> <br />"2 AWO BARE, TINNED, SOLID COPPER TO SHElTER CORNERS ITYPICAL 4 PLACES) <br /> <br />1IIIi~ <br />. ... . ~~. <br /> <br />........ ~ <br />lI'EXTEL CORPORATION <br />4710 EISENHO\li'ER BLVD, <br />BLDG, D-1 <br />TAMPA, FLORIDA 33634 <br />(813) 806-4000 <br /> <br />BIRD LAKE <br />SITE No, FW412-B <br /> <br />I DA.TE:DECEMBER '3,2005 <br /> <br />RE VISIONS <br />NO. <br />, <br /> <br />DATE <br />ISSUED FOR CONSTRUCTiON <br /> <br />2 <br />3 <br /> <br />5 <br />6 <br /> <br />t;" KC~ <br /> <br />A _ TECHNOLOGl~ <br />nORIDA UCENSE 'vO.: EB0004898 <br />KCI TECHNOLOGIES, INC. <br />10150 HIGHLAND MANOR DRlVI <br />SUITE 120 <br />TAMPA. FLORIDA 33610 <br />(813) 7~2300 <br />LUIS G. VARG_o\S JR" P.E, UCE,VSE 'vO. 521, <br />T~ DRA~NG ~ COPYR~HTED A.ND ~ <br />PROPERTY Of NEXTEL SOUTH CORPO~ <br />IT ~ PRODUCED SOLELY FOR USE BY <br />NEXTEL ~ ITS AfFILIATES, REPROOU <br />OR USE Of' T~ DRA.wlNG OO/OR TH <br />ATlON CONTAl~D IN IT IS rORBOOEN <br />THE WRITTEN PERMISSION Of' NEXTEL <br />SOUTH CORPORATION, <br /> <br />I SHE NAME <br /> <br />BIRD lAKE <br /> <br />I SITE NUME!€R : <br /> <br />FL-3412-B <br /> <br />I SITE .ADDRESS <br /> <br />38122 HENRY DRIVE <br />ZEPHYRHlllS, FLORIDA 3354( <br />(PASCO COUNTY) <br /> <br />I_~HJP TITLE <br /> <br />GROUflmlNG PLAN <br /> <br /> <br />10054 100 AS <br />