<br />PROJECT:
<br />O\.lNER:
<br />
<br />LIGHT\.IEIGHT SHELTERS
<br />NEXTEL COMMUNICATIONS
<br />NATIONAL PROJECT
<br />
<br />MANUFACTURER MODEL FLORIDA APPROVAL #
<br />
<br />XTERIOR FACE MATERIAL
<br />SIDING
<br />
<br />FLORIDA APPROVED COMPONENTS
<br />
<br />LOCA TION:
<br />
<br />STONEFLEX URP, L TD,
<br />
<br />5424,1
<br />
<br />VARIOUS
<br />SITE # TBD
<br />
<br />SHEL TER SIZE
<br />
<br />MODEL
<br />NUMBER
<br />XPN12209/NR-130C-AGGR
<br />XPN122 09/1F R-130C- AG GR
<br />XPNI2209/2FR-130C-AGGR
<br />PN12209/2fR/UNI-I3QC-AGGR
<br />XPNI0~09/NR-130C-AGGR
<br />XPNI0209/1FR-130C-AGGR
<br />XP Nl0209/aFR-13QC- AGGR
<br />XPNI0209/2fR/UNI-130C-AGGR
<br />
<br />APPROX.
<br />'<<EIGHT i5;!'
<br />10,500 LBS,
<br />16,250 LBS.
<br />18.750 LBS.
<br />17,750 LBS.
<br />10,000 LBS.
<br />15,000 LBS.
<br />17,500 LBS,
<br />16,600 LBS.
<br />
<br />REVIEW OATE:.&!r -" ,I cIc '\
<br />CITY OF ZEPHY L~ Sc...k .
<br />BUILDING OFFICIAL) J'-' f D )'
<br />
<br />RATING
<br />
<br />NON-FR
<br />1 HR FR
<br />2 HR FR
<br />2 HR FR
<br />NON-FR
<br />1 HR fR
<br />2 HR FR
<br />2 HR FR
<br />
<br />DOOR
<br />HOLLOW' METAL
<br />DOOR/FRAME
<br />DM SERIES DOORS
<br />ME SERIES FRAMES
<br />
<br />. 12' x 20'
<br />
<br />CECO
<br />
<br />4553
<br />
<br />'<<INDSOR REPUBLIC DOOR, INC.
<br />
<br />3101.2
<br />
<br />10' x 20'
<br />
<br />MANUFACTURER, PRECISION QUINCY CORP,
<br />1625 \.I, LAKE SHORE DR,
<br />\.IOODSTOCK1 IL 60098
<br />
<br />LABEL AND DATA LOCATION:
<br />PQ LABEL -ON THE ACCESS DOOR1 INSIDE THE BUILDING
<br />STATE ~ DATA PLATE - ON THE LOAD CENTER
<br />
<br />Plan Design # 05-0835
<br />Date October 14, 2005
<br />Approved By Andrew R, CaFfson
<br />Modular Buildings Plans Examiner
<br />Florida license No, SMP-0000032
<br />
<br />SERIAL NUMBER, TBD
<br />
<br />APPLICABLE CODES'
<br />2004 FLORIDA BUILDING CODE
<br />2004 FLORIDA MECHANICAL CODE
<br />2002 NATIONAL ELECTRICAL CODE
<br />CAPACITYI
<br />W'IND LOAD CAPACITY - 130 MPH ~
<br />EXPOSUREI C
<br />IMPORT ANCE F ACToRI 1.0
<br />BUILDING CATEGORY' II
<br />INTERNAL PRESSURE COEFlCIENT' +1- ,18
<br />COMPONENTS AND CLADDING LOADING.
<br />ROOF ZONE 11 +33,6 PSF, -36,8 PSF
<br />ROOF ZONE 21 +33,6 PSF, -43,1 PSF
<br />ROOF ZONE 31 +33,6 PSF, -43.1 PSF
<br />W'ALL ZONE 41 +36,8 PSF, -39,9 PSF
<br />W'ALL ZONE 51 +36,8 PSF, -49,2 PSt
<br />FLOOR LIVE LOAD CAPACITY - 225 PSF
<br />SNOW' LOAD CAPACITY - 80 PSF
<br />OCCUPANCY IUSEI B
<br />CONSTRUCTION TYPEr V-B
<br />EXTERNAL W'ALL FIRE RESISTACE RATINGl 0,1 OR 2 HR
<br />MINIMUM SETBACKSI GREATER THAN 10' FROM COMMON OR
<br />ASSUMED PROPERTY LINE,
<br />
<br />tiQill
<br />L BUILDING NOT iNTENDED FOR HUMAN OCCUPANCY,
<br />2. THIS BUILDING SHALL NOT BE LOCATED ON PROPERTY
<br />W'HERE ACCESSIBILITY IS REQUIRED,
<br />3. PLUMBING FACILITIES ARE BASED ON LOCAL JURISDICTION.
<br />4. BUILDING EXEMPT FROM ENERGY CODE - FBC 13-101,5.7(5)
<br />5, PLANS COMPLY WiTH RULE 9B-72 (PRODUCT APPROVAL>
<br />
<br />
<br />DRA \.lINGS
<br />
<br />XP-N-OQ-03-FL PROJECT INFORMATION (REV. A - 10/12/05)
<br />XP-N-00-00-7 CONSTRUCTION DETAIL (2 SHEETS REV, A - 10/12/05)
<br />XP-A-00-00-8 OPENING DETAILS (2 SHEETS REV, J - 03/29/04)
<br />XP-N-I0-00-FL3 EXTERIOR ELEVATION (REV. A - 10/12/05)
<br />XP-N-20-00-0 INTERIOR GROUNDING !I. CONDUiT DETAIL (2 SHEETS REV. J - 06/29/05)
<br />XP-N-30-00-0 CABLE LAYOUT <REV. E - 04/30/04)
<br />XP-N-40-00-Q VAC SCH. !I. VDC ALARM SCH, <3 SHEETS REV, K - 06/29/05)
<br />XP-N-50-00-Q BILL OF MATERIAL (REV, H - 08/18/05)
<br />XP-N-60-0Q-0 LIFTING !I. FOUNDATION RECOMMENDATIONS (2 SHEETS REV. E - OS/24/04)
<br />
<br />t:Z~ /' L/
<br />--
<br />
<br />....... listing Agency Approval
<br />~ PYRAMID1, INC.
<br />
<br />These details have been reviewed
<br />fa, conformance with the Florida
<br />Manufactured Building Act of 1979
<br />and adhere to the following criteria,
<br />
<br />Construction Type VB
<br />Occupancy Classjfication:~
<br />AJlowable # of Floors 1
<br />Wind Veioclty 130 ma.h.
<br />Fire Rating (ext. walls) 0 1 2 hF.
<br />Floor Load 225 as.f.
<br />Date of ReView October 14 2005
<br />Manufacturer Precision QUincy Coro .
<br />High Velocity Hurricane Zone .l!L
<br />
<br />IDRA\.IINGS CAN ALSO BE MIRRORED I
<br />
<br />CERTIFIED FIRE RATING DESIGN
<br />CEILING/FLOOR - GA FIL NO, FC 4503
<br />(uSED FOR 1 HR)
<br />- oMGEA POINT ASTM E119-00A CERTIFIED TEST
<br />NO, 16556-112920 REVISION 1 JANUARY 10, 2003
<br />(USED FOR 1 OR 2 HR)
<br />- OMEGA POINT ASTM E119-00A CERTIFIED TEST
<br />NO. 16556-117339 REVISION 1 FEBRUARY 25, 2004
<br />(USED FOR 1 DR 2 HR)
<br />WALLS - 2 HRI UL DESIGN 423
<br />UL DESIGN 425
<br />- 1 HRI UL DESIGN 423
<br />
<br />BUILDING SHALL COMPLY WITH
<br />ALL APPLICABLE BUILDING,
<br />ELECTRICAL, PLUMBING AND
<br />MECHANICAL CODES,
<br />
<br />(j?J
<br />
<br />CUSTOMER'
<br />
<br />ASSEMBL Yr
<br />
<br />
<br />
<br />TITLE.
<br />
<br />DESCRIPTION DATE:
<br />
<br />PRECISION QUINCY CORP.
<br />1625 'J. LAKE SHORE DR" 'JOODSTDCK, IL 60098
<br />PHONE' 815 338-2675, FAX' 815 338-2960
<br />
<br />STANDARD
<br />SHELTER
<br />PROJECT INFORMATION
<br />
<br />D'<<G II'
<br />XP-N-OO-03-FL
<br />
<br />NEXTEL
<br />XP
<br />
<br />
<br />SCALE'
<br />1//=11/
<br />
<br />SHEET
<br />1 OF 1
<br />
|