Laserfiche WebLink
<br />PROJECT: <br />O\.lNER: <br /> <br />LIGHT\.IEIGHT SHELTERS <br />NEXTEL COMMUNICATIONS <br />NATIONAL PROJECT <br /> <br />MANUFACTURER MODEL FLORIDA APPROVAL # <br /> <br />XTERIOR FACE MATERIAL <br />SIDING <br /> <br />FLORIDA APPROVED COMPONENTS <br /> <br />LOCA TION: <br /> <br />STONEFLEX URP, L TD, <br /> <br />5424,1 <br /> <br />VARIOUS <br />SITE # TBD <br /> <br />SHEL TER SIZE <br /> <br />MODEL <br />NUMBER <br />XPN12209/NR-130C-AGGR <br />XPN122 09/1F R-130C- AG GR <br />XPNI2209/2FR-130C-AGGR <br />PN12209/2fR/UNI-I3QC-AGGR <br />XPNI0~09/NR-130C-AGGR <br />XPNI0209/1FR-130C-AGGR <br />XP Nl0209/aFR-13QC- AGGR <br />XPNI0209/2fR/UNI-130C-AGGR <br /> <br />APPROX. <br />'<<EIGHT i5;!' <br />10,500 LBS, <br />16,250 LBS. <br />18.750 LBS. <br />17,750 LBS. <br />10,000 LBS. <br />15,000 LBS. <br />17,500 LBS, <br />16,600 LBS. <br /> <br />REVIEW OATE:.&!r -" ,I cIc '\ <br />CITY OF ZEPHY L~ Sc...k . <br />BUILDING OFFICIAL) J'-' f D )' <br /> <br />RATING <br /> <br />NON-FR <br />1 HR FR <br />2 HR FR <br />2 HR FR <br />NON-FR <br />1 HR fR <br />2 HR FR <br />2 HR FR <br /> <br />DOOR <br />HOLLOW' METAL <br />DOOR/FRAME <br />DM SERIES DOORS <br />ME SERIES FRAMES <br /> <br />. 12' x 20' <br /> <br />CECO <br /> <br />4553 <br /> <br />'<<INDSOR REPUBLIC DOOR, INC. <br /> <br />3101.2 <br /> <br />10' x 20' <br /> <br />MANUFACTURER, PRECISION QUINCY CORP, <br />1625 \.I, LAKE SHORE DR, <br />\.IOODSTOCK1 IL 60098 <br /> <br />LABEL AND DATA LOCATION: <br />PQ LABEL -ON THE ACCESS DOOR1 INSIDE THE BUILDING <br />STATE ~ DATA PLATE - ON THE LOAD CENTER <br /> <br />Plan Design # 05-0835 <br />Date October 14, 2005 <br />Approved By Andrew R, CaFfson <br />Modular Buildings Plans Examiner <br />Florida license No, SMP-0000032 <br /> <br />SERIAL NUMBER, TBD <br /> <br />APPLICABLE CODES' <br />2004 FLORIDA BUILDING CODE <br />2004 FLORIDA MECHANICAL CODE <br />2002 NATIONAL ELECTRICAL CODE <br />CAPACITYI <br />W'IND LOAD CAPACITY - 130 MPH ~ <br />EXPOSUREI C <br />IMPORT ANCE F ACToRI 1.0 <br />BUILDING CATEGORY' II <br />INTERNAL PRESSURE COEFlCIENT' +1- ,18 <br />COMPONENTS AND CLADDING LOADING. <br />ROOF ZONE 11 +33,6 PSF, -36,8 PSF <br />ROOF ZONE 21 +33,6 PSF, -43,1 PSF <br />ROOF ZONE 31 +33,6 PSF, -43.1 PSF <br />W'ALL ZONE 41 +36,8 PSF, -39,9 PSF <br />W'ALL ZONE 51 +36,8 PSF, -49,2 PSt <br />FLOOR LIVE LOAD CAPACITY - 225 PSF <br />SNOW' LOAD CAPACITY - 80 PSF <br />OCCUPANCY IUSEI B <br />CONSTRUCTION TYPEr V-B <br />EXTERNAL W'ALL FIRE RESISTACE RATINGl 0,1 OR 2 HR <br />MINIMUM SETBACKSI GREATER THAN 10' FROM COMMON OR <br />ASSUMED PROPERTY LINE, <br /> <br />tiQill <br />L BUILDING NOT iNTENDED FOR HUMAN OCCUPANCY, <br />2. THIS BUILDING SHALL NOT BE LOCATED ON PROPERTY <br />W'HERE ACCESSIBILITY IS REQUIRED, <br />3. PLUMBING FACILITIES ARE BASED ON LOCAL JURISDICTION. <br />4. BUILDING EXEMPT FROM ENERGY CODE - FBC 13-101,5.7(5) <br />5, PLANS COMPLY WiTH RULE 9B-72 (PRODUCT APPROVAL> <br /> <br /> <br />DRA \.lINGS <br /> <br />XP-N-OQ-03-FL PROJECT INFORMATION (REV. A - 10/12/05) <br />XP-N-00-00-7 CONSTRUCTION DETAIL (2 SHEETS REV, A - 10/12/05) <br />XP-A-00-00-8 OPENING DETAILS (2 SHEETS REV, J - 03/29/04) <br />XP-N-I0-00-FL3 EXTERIOR ELEVATION (REV. A - 10/12/05) <br />XP-N-20-00-0 INTERIOR GROUNDING !I. CONDUiT DETAIL (2 SHEETS REV. J - 06/29/05) <br />XP-N-30-00-0 CABLE LAYOUT <REV. E - 04/30/04) <br />XP-N-40-00-Q VAC SCH. !I. VDC ALARM SCH, <3 SHEETS REV, K - 06/29/05) <br />XP-N-50-00-Q BILL OF MATERIAL (REV, H - 08/18/05) <br />XP-N-60-0Q-0 LIFTING !I. FOUNDATION RECOMMENDATIONS (2 SHEETS REV. E - OS/24/04) <br /> <br />t:Z~ /' L/ <br />-- <br /> <br />....... listing Agency Approval <br />~ PYRAMID1, INC. <br /> <br />These details have been reviewed <br />fa, conformance with the Florida <br />Manufactured Building Act of 1979 <br />and adhere to the following criteria, <br /> <br />Construction Type VB <br />Occupancy Classjfication:~ <br />AJlowable # of Floors 1 <br />Wind Veioclty 130 ma.h. <br />Fire Rating (ext. walls) 0 1 2 hF. <br />Floor Load 225 as.f. <br />Date of ReView October 14 2005 <br />Manufacturer Precision QUincy Coro . <br />High Velocity Hurricane Zone .l!L <br /> <br />IDRA\.IINGS CAN ALSO BE MIRRORED I <br /> <br />CERTIFIED FIRE RATING DESIGN <br />CEILING/FLOOR - GA FIL NO, FC 4503 <br />(uSED FOR 1 HR) <br />- oMGEA POINT ASTM E119-00A CERTIFIED TEST <br />NO, 16556-112920 REVISION 1 JANUARY 10, 2003 <br />(USED FOR 1 OR 2 HR) <br />- OMEGA POINT ASTM E119-00A CERTIFIED TEST <br />NO. 16556-117339 REVISION 1 FEBRUARY 25, 2004 <br />(USED FOR 1 DR 2 HR) <br />WALLS - 2 HRI UL DESIGN 423 <br />UL DESIGN 425 <br />- 1 HRI UL DESIGN 423 <br /> <br />BUILDING SHALL COMPLY WITH <br />ALL APPLICABLE BUILDING, <br />ELECTRICAL, PLUMBING AND <br />MECHANICAL CODES, <br /> <br />(j?J <br /> <br />CUSTOMER' <br /> <br />ASSEMBL Yr <br /> <br /> <br /> <br />TITLE. <br /> <br />DESCRIPTION DATE: <br /> <br />PRECISION QUINCY CORP. <br />1625 'J. LAKE SHORE DR" 'JOODSTDCK, IL 60098 <br />PHONE' 815 338-2675, FAX' 815 338-2960 <br /> <br />STANDARD <br />SHELTER <br />PROJECT INFORMATION <br /> <br />D'<<G II' <br />XP-N-OO-03-FL <br /> <br />NEXTEL <br />XP <br /> <br /> <br />SCALE' <br />1//=11/ <br /> <br />SHEET <br />1 OF 1 <br />