Laserfiche WebLink
<br />-------------.-., <br /> <br />EXiSTiNG CRAVEl_ <br />THROUCHOUT <br />COMPOUND <br /> <br />3 "3/0 AWC THWN ----........ <br />. IlI6 Awe GRNO <br />IN 2" PYC fO ME fER <br />ON RACK(j) <br /> <br />1,2 '/1" PYC CONOuT FOR- <br />TELCO SERVJ<:E. EXTEND <br />TO EXISTINC TELCO SOX <br />LOCATED INSIDE COIAPOUND, <br />APPRO x 60' NOR TH OF <br />TERMINAT'9!I POINT ON <br />SHEL TER \!) <br /> <br />fUTURE GENERATOR- <br />ON 6'XI2' CONe PAD <br /> <br />NEXTEL~ <br />EQ\;IPI,4(,NT ______ <br />SHEL TER <br />11.~'X20' @) <br /> <br />TELCO SACKSOARO- <br />PROYIO€D WITH <br />SHEL TER QXD <br /> <br />~ EXISTING DIRT DRIVE ~ <br /> <br />EXISTING UTILITY <br />POLE NEXT[L POWER <br />SOURC~ <br /> <br />,\. <br />,/ <br />,/ <br /> <br />EXISTING ACCESS DRiVE <br /> <br /> <br />EX IS TING 16' <br />ACCESS GATE <br /> <br />-0- <br /> <br /> <br />~XiSTING TREES <br />~ ~O REMAIN <br /> <br />EXISlING TREES ~ <br />TO REMAIN ~ <br /> <br />EXISTING TELC'O BOX~ <br />(TELCO SOURCE' <br /> <br />- 'T- - 'T- <br /> <br /> <br /> <br />EXISTING ~ <br />UTILITY POLE <br />(T~PI <br /> <br />'" <br />I <br />I <br /> <br />I ...-T- <br /> <br />iL <br />II <br />II <br />'I <br /> <br /> <br /> <br />I I 3"3/0 AWO THWN <br />I "lI6 AWC GRNO <br />I IN 2" Pvc TO !oITS IN <br />SHEL TER I <br /> <br />r- <br /> <br />lLT-;--T <br /> <br />EXIS TiNG SPRIN T <br />EQUPMENT PAD WI <br />CABINETS <br /> <br /> <br />EXISTING T-MOBILE <br />EQUIPMENT PAD WI <br />CABINE TS <br /> <br /> <br />CINGUL AR <br />EQUIPMENT <br />SHEL TER <br /> <br /> <br />PROPOSEO POWER CO, <br />METER AND SERV I CE <br />01 SCQNNECT. lo()UNTED <br />ON RACK, SEE DETAIL <br />TH I S SHEE T CD <br /> <br />o <br /> <br />EXIS TlNG <br />WAVEGUIDE <br />BRIDGE (TYP.) <br /> <br />EXISTING <br />CH"N LINK FENCE <br /> <br />EXIS TlNG VERIZON <br />METER ON <br />UTILITY POLE <br /> <br />EXISTING T-MOBIlE <br />ME TER AND DISCONNEC T ON <br />UTIlITY POLE <br /> <br />COMPOUND DEI All NOTES: <br /> <br />(j) t~~b~fs2p0rt\~~E~oS~~U~~~Y l~ASm~Dp~ty~~~A"8.Eo~01'1f pTu\\CO . POWER <br />LINE TO BE INSTN.lED AFTER USING A BRUSH MANDRIL IN CONDUITS CAP CONDUITS <br />UNTIL READY TO TERMINATE <br />o ~it~TiH~O~~~~ ~~~~~0~~~Eu9R~~Jj~L TER COORDINATE MOUNTING <br /> <br />Q) g~N~~JfR T~nf~ JH5SEW ~LpR~~RIW E B~A~~ ~E8A NRI~ %~'DfH~ t~:SR(R0~~;0~NCg~~N <br />AlL SURf ACES Of EXCESS MATERIAL SLEEVE THROVCH WN.l fOR UT!l_IT~S, SLEEVE <br />SIZE SHALL BE NO MORE THAN I" DIAMETER LARGER THAN CONOUIT OR CABLE. <br /> <br />CD ~~~~Nlft';~~;;~IJJ"~~~V~~O~?TE~ ~'1..~tEl TER TERMNATE FEEDER AT MTS <br /> <br />@ SHEl TER IS PRE-w'RED AND COMES COMPLETE WITH PANEl, SlRCE ARRESTDR, LIGHTING, <br />RECEPTACLE, HVAC AND GROVNDING, AlSO INCLUOED ARE N.L AlAR,,",S AND ASSOCIATED <br />E QUIPME NT, <br />@ COORDI~ATE INCO,,",ING SERVICE WITH 8ACKBOARD LOCATION. <br />(j) ~~~0'NS~,ip60~~INATE AT THE PROPOSED SOURCE' TElCO BOX lOCATED ON UTILITY <br /> <br />GENERAL NOTES: <br /> <br />I, APPLY FOR UTILITY SERVICE <TELEPHONE AND ELECTR!Cl NO LATER THAN THE NEXT BUSINESS DAY <br />FOLLOWINC AWARD Of CONTRACT. COORDINATE WITH ELECTRIC UTILITY COMPANY FOR EXACT <br />TRANSFORMER OR POLE lOCATION, METERING REQUIREMENTS, AND SERVICE ROVTING COORDINATE <br />WITH TElEPHONE UTIlITY COMPAN~ FOR EXACT TElEPHONE REQUIREMENTS AND ROUTING Of SERVICE. <br /> <br />2. PRIOR TO SiTE EXCAVATION, VERIfY lOCATiON Of N.L BI,;RIED UTILITIES <br /> <br />J. SEAl AlL CONDUIT PENETRATIONS INTO BUILDING IDOWNLEA<DS, PQWER CONDUiTS, TElEPHONE <br />CONDUIT INSIDE AND OUTSIDE Of BUILDINC <br /> <br />. CONTRACTOR SHALL COORDINATE TRENCHING ACTIVITIES WITH EXISTiNG UNDERGROUND <br />SYSTEMS. All NEW UNDERGROUND SHALL BE BURIED TO A MINIMU,,", OF 30" BfG <br /> <br />I 1 r 30" MINIMUM " " ' <br /> <br />II to2 AWG BARE, TINNED, <br />\~. I - ~ SOLID COPPER CONDUCTOR, <br />\ ExTERIOR CROUND RINC <br /> <br />'- ELECTRIC SERVICE IN 2" SCH. 40 <br />PVC CONDUIT TO ExTEND TO H-FRAME <br />RACK COORDINATE ExTENSION WITH <br />LOCAl UTILITY COt.4PAN~ <br /> <br />WALL ELEVATION UTILITY SERVICE DETAIL <br /> <br />12",12",4" PVC ~NCTION <br />BOX NEMA 4 RATED, MKJUNTED <br />TO WAlL SLEEVE CONDUiT THRU <br />TO TElCO BACKBOARD <br />APPRQX 18" AfG <br /> <br />eFCI <br />RECEPT ACLE <br />120V.l20A. <br /> <br /> <br />30" MINIMUM <br /> <br />1212" PVC TElCO CONDvIT. CONOUIT <br />TO EX TEND TO TELCO BOX ON <br />H-FRAME RACK COORDINATE <br />ExTENSiON WITH ~'II'I <br />LOCAL UTlIT~S I <br />IIII <br />\: iI) <br /> <br />NOT TO SCAlE <br /> <br />POIIER CO METER PROViDED AND INSTAllED BY <br />POWER CO UTILITY APPROVED BACKeox PROVIDED <br />AND INSTN.LED BY THE SUB-CONTRACTOR <br />COORDINATE REOUIREMENTS WiTH THE URITY <br />COMPA<NY, <br /> <br />2" Res WITH J <*3/0 AWG THWN <br /> <br /> <br />METER BONO & DISCONNECT <br />BONO, to2 AWG BARE, TlN~D. <br />SOLiD COPPER <br /> <br />[] <br /> <br />CONDUIT BODY INTO WAll. <br />SLEEVE THRU WALL <br />TO MTS APPR'OX 62" AFG <br /> <br />o <br /> <br />. . <br /> <br /> <br />~ROPOSED SERVICE H-FRAME RACK <br /> <br />SURGE SUPPRESSOR, BY SUS-CONTRACTOR <br />SIZE PER EOUIP SUPPLIERS RECOMMENDATIONS <br />SERVICE ENTRANCE CIRCUIT BREAKER <br />2P,200 AMPS IN A NEMA JR ENClOSVRE <br /> <br />EXPOSED CONDUIT; Res <br /> <br />#4 AWC SERVICE CRD iN \" PVC <br /> <br />to2 Awe BARE. TINNED, I <br />SOLID COPPER METER II fl <br />AND SWiTCH BONO J) L <br />2" pvC WITH <br />3#3/0 AWG THWN <br />SERVICE ENTRANCE GROUN/ : "310 AWG THWN ~ <br />ROO, 5/8" , 10' COPPER 1 ..e AWG GRND IN <br />GROUND ROO 2" PVC TD SHEl TER <br /> <br />TYPICAL SERVICE RACK RISER DIAGRAM <br />NOT TO SCN.E <br /> <br /> <br />EXISTING SERVICE AT CLOSEST AVAILABLE <br />UTILITY SOVRCE APPRO X 120' TO THE <br />NORTH AT EXISTING POIIER POLE <br />JJ "3/0) <br />120/240V, SINGLE-PHASE, 200 AWf' ElECTRIO METER <br />FURNISHED BY UTILITY COMPAN~ AND INSTALlED BY <br />THE SU8-CONTRACTOR COOROt<ATE REOUIR!:MEN1S <br />WITH THE UTILITY COMPAN~ <br />BOI\O CON~UCTOR TO GROUND RING AND SERVICE <br />GROUND (VERIfY WITH U1t.ITY COMPANH #2 AwG <br />~ SOLiD BARE TlNNEO COPPER <br /> <br /> <br />I ~'2D/24DV DISCONNECT MKJUNTEQ ON H-FRAME RACK <br />2P,200 AMP, FUSED AT 200 AMPS <br /> <br />3 <*3/0~ <br />IN 2" PV.C _ __________ <br />RGS NIPPLE <br />SERVICE GROUND\ <br /><l4 Awe .~ <br /> <br />3 <*3/0 & l..e GRD <br />IN 2" PVC CONDUIT <br /> <br /> <br />GENERATOR RECEPTACLE fURNISHED <br />WITH SHELTER AND INSTN.LEO UNDER <br />THIS C'ONTRACT <br /> <br />MANI,;Al TRANSfER SWITCH <br /> <br />-PANELBOARD <br /> <br />ONE LINE DIAGRAM <br />NOT TO SCN.E <br /> <br />1- EQUIPMENT LOCATED WITHIN DASHED LINES <br />_ ~T IS NOT IN THIS CONTRACT AND IS SHOWN <br />FOR INfORMATION ONLY <br /> <br /> <br />NEXTEL CORPORATION <br />4710 EISESHO'WER BLVD_ <br />BLDG, D-I <br />TAMPA" FLORIDA 33634 <br />(813) 806--4000 <br /> <br />BIRD LAKE <br /> <br />SITE No, FL--3412-B <br /> <br />I O,A, TEDEC(M8(R 13,2005 <br /> <br />RtVISIQNS <br />NO <br />1 <br /> <br />OA.TE <br />iSSUED FOR CONSTRUCTION <br /> <br />2 <br />3 <br />4 <br />5 <br />6 <br /> <br />.. <br /> <br />:: KC] <br /> <br />.. _ TECHNOLOGIE <br />F'LORlDA lJCESSE ,va,: EBo<m890 <br />KCI TECHNOLOGIES, INC, <br />10150 HIGHU\NO MANOR DRI~ <br />SUITE 120 <br />TAMPA. flORIDA 33610 <br />(813) 740-2300 <br />LUiS Q, VARGAS JR" P.E_lJCENSE .va. 52 <br />THIS DRAWIN(; IS COPYRJ(;HTW NolO , <br />PROPERTY Of NEXTEL SOUTH CORPO <br />iT is PRODUCED SOUL'( FOR USE B' <br />N[xTEL ,A,N() ITS foiFIlIATES, REPROO <br />OR USE Of THIS DRAWINC lIND/OR T' <br />A.TION CONT.6U:O IN IT is FORBOOEN <br />THE WRITTEN PERMISSiON Of N(XTEL <br />SOUTH CORPORATiON <br /> <br />I SITE NAME <br /> <br />BIRD LAKE <br /> <br />I SITE NUM8(R , <br /> <br />FL-3412-B <br /> <br />I SHE ADORESS <br /> <br />38122 HENRY DRIVE <br />ZEPHYRHILLS, FLORIDA 33! <br />(PASCO COUNTY) <br /> <br />'..s.tifET TITLE <br /> <br /> <br />WfR ANu TELCO PLA <br /> <br />10054100A8 <br />