<br />PROJECT:
<br />O\v'NER:
<br />
<br />LIGHT\v'EIGHT SHELTERS
<br />NEXTEL COMMUNICATIONS
<br />NATIONAL PROJECT
<br />
<br />MANUFACTURER
<br />
<br />MODEL
<br />
<br />XTERIOR rACE MATERIAL
<br />SIDING
<br />
<br />5424.1
<br />
<br />FLORIDA APPROVED COMPONENTS
<br />
<br />FLORIDA APPROVAL It
<br />
<br />LOCA TION:
<br />
<br />STONErLEX URP, LTD.
<br />
<br />VARIOUS
<br />SITE # TBD
<br />
<br />SHELTER SIZE
<br />
<br />MODEL
<br />NUMBER
<br />XPN12209/NR-130C-AGGR
<br />XPN12 209/1F R-130C - AG GR
<br />XPNIZ209/2FR-13OC-AGGR
<br />PN12209/2fR/UNI-130C-AGGR
<br />XPNI0209/NR-130C-AGGR
<br />XPN102091 lFR-130C -AGGR
<br />XPN10209/2fR-13QC-AGGR
<br />XPN10209/2FR/UNI-l3OC-AGGR
<br />
<br />REVIEW DATE: ,I, [/ ~\..,
<br />ClTYOFZEPHY~ [~(}..~ F'\
<br />BUILDING OFFICIAL~ D
<br />
<br />APPROX.
<br />W'EIGHT :t5;/'
<br />10,500 LBS.
<br />16,250 LBS.
<br />19.750 LBS.
<br />11,750 LBS.
<br />10,000 LBS,
<br />15,000 LBS,
<br />17,500 LBS.
<br />16,600 LBS.
<br />
<br />RA TING
<br />
<br />NON-fR
<br />1 HR FR
<br />2 HR fR
<br />2 HR FR
<br />NON-FR
<br />1 HR fR
<br />2 HR fR
<br />2 HR fR
<br />
<br />DOOR
<br />HOLLOW' METAL
<br />DOOR/fRAME
<br />DM SERIES DOORS
<br />ME SERIES fRAMES
<br />
<br />12' x 20'
<br />
<br />CECD
<br />
<br />4553
<br />
<br />W'INDSOR REPUBLIC DOOR, INC.
<br />
<br />3101.2
<br />
<br />10' x 20'
<br />
<br />MANUFACTURER: PRECISION QUINCY CORP,
<br />1625 'W, LAKE SHORE DR,
<br />'WOODSTOCK1 IL 60098
<br />
<br />LABEL AND DATA LOCATION:
<br />PQ LABEL -ON THE ACCESS DOORJ INSIDE THE BUILDING
<br />STATE ~ DATA PLATE - ON THE LOAD CENTER
<br />
<br />Plan Design # 05-0835
<br />Date October 14, 2005
<br />Approved By Andrew R, Carlson
<br />Modular Buildings Plans Examiner
<br />Florida License No, SMP-0000032
<br />
<br />SERIAL NUMBER: TBD
<br />
<br />APPLICABLE CODES,
<br />
<br />2004 FLORIDA BUILDING CODE
<br />2004 FLORIDA MECHANICAL CODE
<br />2002 NATIONAL ELECTRICAL CODE
<br />
<br />CAPACITY' /
<br />W'IND LOAD CAPACITY - 130 MPH
<br />EXPDSUREI C
<br />IMPORTANCE FACTOR. 1.0
<br />BUILDING CATEGORYI II
<br />INTERNAL PRESSURE COEFICIENTI +/- .18
<br />COMPONENTS AND CLADDING LOADINGI
<br />ROOf" ZONE 11 +33.6 PSF, -36.8 PSF'
<br />ROOf ZONE 21 +33.6 PSF, -43.1 PSF'
<br />ROOf ZONE 3. +33.6 PSF, -43.1 PSF
<br />"ALL ZONE 41 +36.8 PSF. -39,9 PSF'
<br />"ALL ZONE 51 +36,8 PSF, -49.2 PSF
<br />FLOOR LIVE LOAD CAPACITY - 225 PSF'
<br />
<br />SNo" LOAD CAPACITY - 80 PSF'
<br />OCCUPANCY/USE. B
<br />CONSTRUCTION TYPE' V-B
<br />EXTERNAL "ALL F'lRE RESISTACE RATINGI 0,1 DR 2 HR
<br />
<br />MINIMUM SETBACKSI GREATER THAN 10' FROM COMMON OR
<br />ASSUMED PROPERTY LINE.
<br />
<br />t:m.E..S
<br />1. BUILDING NOT INTENDED FOR HUMAN OCCUPANCY,
<br />2, THIS BUILDING SHALL NOT BE LOCATED ON PROPERTY
<br />"HERE ACCESSIBILITY IS REQUIRED.
<br />3, PLUMBING FACILITIES ARE BASED ON LOCAL JURISDICTION.
<br />4, BUILDING EXEMPT FROM ENERGY CODE - FBC 13-101.5.7(5)
<br />5. PLANS COMPLY "ITH RULE 9B-72 (PRODUCT APPROVAL>
<br />
<br />
<br />DRA 'WINGS
<br />
<br />XP-N-00-03-FL PROJECT INfORMATION (REV, A - 10/12/05)
<br />XP-N-OO-OO-7 CONSTRUCTION DETAIL (2 SHEETS REV, A - 10/12/05)
<br />XP-A-00-00-8 OPENING DETAILS (2 SHEETS REV. J - 03/29/04)
<br />XP-N-10-00-FL3 EXTERIOR ELEVATION (REV, A - 10/12/05)
<br />XP-N-20-00-0 INTERIOR GROUNDING & CONDUIT DETAIL (2 SHEETS REV. J - 06/29/05)
<br />XP-N-30-00-Q CABLE LAYOUT (REV. E - 04/30/04)
<br />XP-N-40-00-Q VAC SCH. & VDC ALARM SCH, (3 SHEETS REV, K - 06/29/05)
<br />XP-N-50-0Q-0 BILL Of" MATERIAL (REV, H - 08/18/05)
<br />XP-N-60-00-0 LIFTING & FOUNDATION RECOMMENDATIONS (2 SHEETS REV. E - 05/24/04)
<br />
<br />a~/~
<br />---
<br />
<br />...... listing Agency Approval
<br />~ PYRAMID1, INC.
<br />
<br />These details have been reviewed
<br />for conformance with the Florida
<br />Manufactured Building Act of 1979
<br />and adhere to the following crileria.
<br />
<br />IDRA'WINGS CAN ALSO BE MIRRORED I
<br />
<br />Construction Type VB
<br />Occupancy Ciass,flcation~
<br />Allowable # of Floors 1
<br />Wind VelOCity' 130 m.p.h.
<br />Fire Rating (exl.walls) 0 1 2 hr.
<br />Floor Load 225 p.s.f.
<br />Date of Review October 14 2005
<br />Manufacturer Precision Quine" COrD
<br />High Velocity Hurricane Zone ...lliL...
<br />
<br />CERTIFIED FIRE RATING DESIGN
<br />CEILING/FLOOR - GA F'lL NO. FC 4503
<br />(USED FOR 1 HR)
<br />- oMGEA POlNT ASTM E119-00A CERTIfIED TEST
<br />NO. 16556-112920 REVISION 1 JANUARY 10, 2003
<br />(USED FOR 1 DR 2 HR)
<br />- OMEGA POlNT ASTM E119-00A CERTIF'lED TEST
<br />NO, 16556-117339 REVISION 1 FEBRUARY 25. 2004
<br />(USED fOR 1 OR 2 HR)
<br />"ALLS - 2 HR' UL DESIGN 423
<br />UL DESIGN 425
<br />- 1 HRI UL DESIGN 423
<br />
<br />COMPlYWrm
<br />~~~~l~~~ BUlLD~~
<br />ELECTRiCAL, PLUMBING
<br />MECHANICAL CODES.
<br />
<br />fi?d
<br />
<br />CUSTOMER'
<br />
<br />ASSEMBl VI
<br />
<br />
<br />
<br />TITLE'
<br />
<br />DATE
<br />
<br />DESCRIPTION
<br />
<br />
<br />PRECISION QUINCY CORP.
<br />1625 W'. LAKE SHORE DR,. IJOODSTOCK, IL 600~a
<br />PHONE' 815 338-2675, FAX, 815 33a-2~60
<br />
<br />NEXTEL STANDARD
<br />XP SHELTER
<br />PROJECT INFORMATION
<br />
<br />IJRDER III DIJG II.
<br />STD XP-N-OO-03-FL
<br />
<br />SCALE.
<br />1"=1"
<br />
<br />SHEET
<br />1 OF 1
<br />
|