My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
06-5487
Zephyrhills
>
Building Department
>
Permits
>
2006
>
06-5487
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:21:49 PM
Creation date
5/9/2007 10:31:47 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
06-5487
Building Department - Name
NEXTEL COUTH COMM
Address
6217 8TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />MAGNETIC DOOR AlARM <br />THE MAGNETIC DOOR AlARM <br />IS WIRED NORMALLY OPEN. I <br />CONTACTS CLOSE UPON <br />DOOR CLOSURE. WHEN DOOR <br />IS OPENED. CONTACTS OPEN <br />SENDING AN AlARM. <br /> <br />MAGNETIC <br /> <br />UTlUiY POWER F NL <br />FOR UTIUiY POWER AlARM, <br />CONNECT TO COMMON AND <br />NORMALLY OPEN TERMINAL <br />BLOCKS. NORMAllY OPEN <br />CONTACTS WILL BE CLOSED <br />IN NORMAL POWt.R <br />CONDITIONS, CONTACTS WilL <br />OPEN IF UTIUiY POWER FAIL <br /> <br />~I <br /> <br />RED J <br />BLK PINS 9,10 <br /> <br />HVA9 11 FAlL AlARM <br />WHEN H1GH PRESSURE OR <br />lOW PRESSURE SWITCHES <br />ACTIVATE THE LOCK OUT <br />REL4.Y, THE ALARM CONTACTS <br />WILL OPEN SENDING AN <br />ALARM. <br /> <br />DOOR ALARM <br /> <br />I :~ <br /> <br />I :~ <br /> <br />REO <br /> <br />BLK <br /> <br />RED <br /> <br />BLK <br /> <br />HIGH TEMP & <br />LOW TEMP ALARMS <br /> <br />I Lj <br /> <br />BLK J <br />REO PINS <br /> <br />HVAC 12 FAIL AlARM <br />WHEN HIGH PRESSURE OR <br />LOW PRESSURE SWITCHES <br />ACTIVATE lriE LOCK OUT <br />REL4.Y, THE AlARM CONTACTS <br />WILL OPEN SENDING AN <br />ALARM. <br /> <br />15,16 <br /> <br />HVAC <br /> <br />COMMERCIAL POWER FAIL <br /> <br />HIGH TEMP. AlARM <br />lriE HIGH TEMP. AlARM IS <br />SET TO OPEN ON TEMP. <br />INCREASE. (OR RISE) <br />SET POINT = 89' F <br /> <br />LOW TEMP. AlARM <br />THE LOW TEMP. AlARM IS <br />SET TO OPEN ON TEMP. <br />DECREASE, (OR FALL) <br />SET POINT = 49' F <br /> <br />J PINS 11,12 <br /> <br />SMOKE AUlRM <br />illE SMOKE AlAR" CONTACTS I <br />ARE NORMAlLY CLOSED <br />UNDER A "NO SMOKE" <br />CONDITION. WHEN SMOKE IS <br />DETECTED lriESE CONTACTS <br />OPEN SENDING AN AlARM. <br /> <br />J PINS 13.14 <br /> <br />TVSS PANEL "A" <br />FOR SURGE ARRESTOR <br />ALARM, CONNECT TO COMMON <br />AND NOR""" Y CLOSED I <br />TERMINAL BLOCKS. NORMALLY <br />CLOSED CONTACTS WILL BE <br />CLOSED IN NORMAL POWER <br />CONDITIONS. CONTACTS WILL <br />OPEN IF TVSS PANEL "A" <br />FAlLS. <br /> <br />HVAC #1 <br />r*~ <br />H~~ <br />L..-- /j' RED <br />~ LOW <br />-VOLTAGE <br />STRIP <br /> <br />eLK <br /> <br />HVAC 12 <br />r*G5 <br />~-H- @ <br />_ /j' RED <br />~ lOW <br />L....- VOLTAGE <br />STRIP <br /> <br />eLK <br /> <br />FAIL ALARM <br /> <br />~ <br /> <br />~ <br /> <br />SMOKE & <br />SURGE ARRESTOR <br />ALARM <br /> <br />K SEE SHEET 1 <br />J SEE SHEET 2 <br />I SEE SHEET 2 <br />H ADJUSTED HI/LO..., TEMP ALARM SETTINGS FROM 45/85 <br />G SEE SHEET 1 <br />REV, DESCRIPTION <br />ACAD #,XPN40000KIPLDT SCALE' <br /> <br />'\ <br /> <br />PINS 3,4 <br /> <br />'\ <br /> <br />PINS 5,6 <br /> <br />eLK J <br />RED PINS 15,16 <br /> <br />BLK J <br />RED PINS 17,18 <br /> <br />...... listing Agency Approval <br />~ PYRAMID1, INC. <br /> <br />These details have been reviewed <br />for conformance with the Florida <br />Manufactured Building Act of 1979 <br />and adhere to the following criteria. <br /> <br />Construction Type VB <br />Occupancy Classlfication----L-....... <br />Allowable # of Floors 1 <br />W,nd Veiocity' 130 m.p.h. <br />Fire Rating (exl.walls) 0 1 2 hr. <br />Floor Load: 225 P.s.f. <br />Date of Review: October 14 2005 <br />Manufacturer Precision Quine..,. Corp. <br />High Velocity Hurricane Zone .l!L <br /> <br />(fd <br /> <br />COMMERCIAL POWER FAlL <br />HVAC 11 FAlL AlARM <br />HVAC #2 FAlL AlARM <br />NOT ASSIGN~D <br />MAGNETIC D09R Au\RM <br />HIGHltMp. AlARM <br />LOW TEMP. AlARM <br />SMOKE AL6.RM <br />SURGE ARRESTOR ALARM <br /> <br />ALARM NOTES: <br />1. AlARMS SHALL BE <br />CONfiGURED FOR FAlL <br />SAFE OPERATION. <br />NORMAlLY CLOSED <br />CONTACTS SHAll OPEN <br />ON AlARM. <br />2. WHERE APPUCABLE <br /> <br />ALARM TERMINAL <br /> <br />'- - <br /> <br />BLOC? f7 <br />I ~/ <br />L~.v <br /> <br />PRECISION QUINCY CORP. <br />1625 IJ. LAKE SHORE DR,. IJOODSTQCK, IL 60098 <br />PHONE' 815 338-2675. FAX. 815 338-2960 <br /> <br />JPH 06/29/05 CUSTOMER> <br />JPH 12/09/04 <br />JPH 07/22/04 ASSDlBL Y, <br />JPH 04/27/04 <br />JPH 04/13/04 TITLE. V A C <br />REG BY, BY CHI< BY fi"rV BY DATE BY' ISCAU:' <br />ICHK BY' IAPPV BY' IDAm 01117/03 AC I NONE <br /> <br />1=11 REQ,BY' <br /> <br />STANDARD <br />XP SERIES <br />SCH, & VDC (ALAR~,,1) SCH, <br />IORDER I' ID\o'G " <br />I STD I XP-N-40-00-0 <br /> <br />3 of' 3 <br />