My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
06-5503
Zephyrhills
>
Building Department
>
Permits
>
2006
>
06-5503
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:21:42 PM
Creation date
5/9/2007 10:49:34 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
06-5503
Building Department - Name
RYMAN CONSTRUCTION
Address
4625 EAGLE RANCH DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />FORM 600A-2001 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRESS: , , , <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPoNENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECI< <br />Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfmlsa.ft. window area' .5 cfmlsa.ft. door area. <br />Exterior & Adjacent Walls 606.1 ,ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility <br /> penetrations; between wall panels & toplbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from and is sealed to the foundation to the ton nlate. <br />Floors 606.1,ABC.1.2.2 Penetrations/openings >118" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the cerimeter penetrations and seams. <br />Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; aroood shafts. chases, <br /> soffit&; ~ cabinets ENIIId to ~RliRUQUS air barrier; gaps-in gyp. board & top-plate; <br /> - , <br /> atik: aeees&. EXCEPTIO~FFaRl8 MiIi. where a continuous-iAftltFatien-barrief-is. <br /> installed ttJet. is--8ea1ed at rations and seam&; <br /> .. <br />Recessed Lighting Fixtures 606.1.ABC,1.2.4 Type--fe rated with no penetratiollS, seeled, orType IC or non-IC rated; instaHed ~lSide a <br /> sealed box wiltrtt2" clearance-&-3"-flom ill....~lion; or Type IC ratect~< 2.0 cfm from <br /> .. ~. tested.-- <br />Multi-storv Houses 606.1.ABC.1.2.5 A1rbarrieron oerimeter of1h:lorcavltvbetWeen floors. <br />Additional Infiltration reqts 606.1.ABC,1.3 EXhaust fans vented to outdOors, dampers; combustion space heaters comply With NFPA, <br /> have combustion air. <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES Imust be met or exceeded bvall residences,) <br />COMPONENTS SECTION REQUIREMENTs CHECK <br />Water Heaters 612.1 Comply with efficiency requirements fn Ta6le 6-12. Switch or clearly marked circuit <br /> breaker (electric) or cutoff (aas) must be Drovided. External or built-in heat tran ~uired, <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efficiencY of 78%. <br />Shower heads 612.1 Water flow must be restricted to no more than 2.5 aallons oer minute at 80 PSIG. <br />Air Distribution Systems 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610, <br /> Ducts in unconditioned attics: R-6 min. insulation, <br />HVAC Controls 607.1 Seoarate readilv accessible manual or automatic thermostat for each sYStem. <br />Insulation 604.1 , 602.1 Ceilings-Min. R-19, Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. <br /> <br />I=nQrn\lr::.~III'IQTM nr:a. r::nrrn ,:u'V\A_?rV'\1 <br /> <br />~nor"",r::.~II"A/fnJ-=Ia.hlC:C:'?rVl1 ~r-~\t:t'"~ <br />
The URL can be used to link to this page
Your browser does not support the video tag.