<br />gradient, load intensity and erosion characteristics of slope <br />material. <br /> <br />1805.4 Footings. Footings shall be designed and constructed in <br />accordance with Sections 1805.4. i through 1805.4,6. <br /> <br />1805.4.1 Design, Footings shall be so designed that the . <br />allowable bearing capacity of the soil is not exceeded, and <br />that differential settlement is minimized. The minimum <br />width of footings shall be 12 inches (305 mm). <br /> <br />Footings in areas with expansive soils shall be designed <br />in accordance with the provisions of Section 1805.8. <br /> <br />1805.4.1.1 Design loads, Footings shall be designed for <br />the most unfavorable effects due to the combinations of <br />loads specified in Section 1605.3. The dead load shall in- <br />clude the weight of foundations. footings and overlying <br />fill, Reduced live loads, as specified In Section 1607.9, <br />are pennitted to be used in designing footings. <br /> <br />1805.4.1.2 Vibratory loads. Where machinery opera- <br />tions or other vibrations are transmitted through the <br />foundation, consideration shall be given in the footing <br />design to prevent detrimental disturbances of the soil. <br /> <br />1805,4.2 Concrete footings, The design. materials and con- <br />struction of concrete. footings shall comply with Sections <br />1805.4,2, I through 1805.4.2.6 and the provisions of Chap- <br />ter 19. <br /> <br />Exception: Where a specific design is not provided, con- <br />crete footings supporting walls of light-frame construc- <br />tion are pennitted to be designed in accordance with <br />Table 1805.4,2. <br /> <br />1805.4.2.1 Concrete strength, Concrete in footings <br />shall have a specified compressive strength if I,) of not <br />less than 2,500 pounds per square inch (psi) (17237 kPa) <br />at 28 days, <br /> <br />1805.4.2.2 Reserved, <br /> <br />SOILS AND FOUNDATIONS <br /> <br />1805.4,2,3 Plain concrete footings. The edge thickness <br />of plain concrete footings supporting walls of other than <br />light-frame construction shall not be less than 8 inches <br />(203 nun) where placed on soil. <br /> <br />Exception: For plain concrete footings supporting <br />Group R-3 occupancies, the edge thickness is permit- <br />ted to be 6 inches (152 nun), provided that the footing <br />does not extend beyond a distance greater than the <br />thickness of the footing on either side of the supported <br />wall. <br /> <br />1805,4,2.4 Placement of concrete. Concrete footings <br />shall not be placed through water unless a tremie or otber <br />. methoO approved by the building official is used. Where <br />placed under or in the presence of water, the concrete <br />shall be deposited by approved means to ensure mini- <br />mum segregation of the mix and negligible turbulence of <br />the water. <br /> <br />1805,4,2,5 Protection of concrete. Concrete footings <br />shall be protected from freezing during depositing and for <br />a period of not less than five days thereafter. Water shall <br />not be allowed to flow through the deposited concrete. <br /> <br />" ,.180S..4.2,6~orming of concrete. Concrete footings are <br />'per@ttedto be cast against the earth where, in the opin- <br />ion of the building official, soil conditions do not require <br />fonning. Where fonning is required, it shall be in accor- <br />dance with Chapter 6 ofAC! 318, <br /> <br />1805.4!3 Masonry-unit footings. The design. materials <br />and construction of masonry-unit footings shall comply <br />with Sections 1805.4,3.1 and 1805.4,3,2, and the provisions <br />of Chapter 21. <br /> <br />Exception: Where a specific design is not provided, ma- <br />sonry-unit footings supporting walls of light-frame con- <br />struction are pennitted to be designed in accordance with <br />Table 1805.4.2, <br /> <br />1805.4,3.1 Dimensions, Masonry-unit footings shall be <br />,laid in Type M or S mortar complying with Section <br /> <br />II <br /> <br />TABLE 1805.4.2 <br />FOOTINGS SUPPORTING WALLS OF UGHT-FRAME CONSTRUCTION.' b, c, d <br /> <br />" WIDTH 011 . ,. I <br /> THICKNESS OF <br />NUMBER OF FLOORS FOOnNQ FOOTING <br />SUPPORTED BY THE FOOTING' (Inoh..) (Inch..) <br />1 12 6 <br />2 15 6 <br />3 18 Sf <br /> <br />II <br /> <br />For 51: I inch = 25.4 mm, J foot = 304,8 mm,. <br />a. Depth" of footings shall be in accordance with Section 1805.2. <br />b. The ground under the floor is permitted to be excavated to the elevation of the top of the footing, <br />c. Interior-stud-bearing walls are permitted to be supported by isolated footings, The footing width and length shall be twice the width shown in this table. and rool' <br />ings shall be spaced not more than 6 feet on center, <br />II d. For thickness of foundation walls, see Section 1805,S. <br />e. Footings are permitted to suppon a roof in addition to the stipulated number of floors, Footings supponing roof only shall be as required for supponing one tloor <br />r. Plain concrete footings for Group R-3 occupancies are permitted to be 6 incites thick. <br /> <br />FLORIDA BUILDING CODe - BUILDING <br /> <br />18.5 <br />