<br />gradient, load intensity and erosion characteristics of slope <br />material. <br /> <br />1805.4 Footings. Footings shall be designed and constructed in <br />accordance with Sections 1805.4, I through 1805.4.6. <br /> <br />1805.4.1 Design, Footings shall be so designed that the. <br />allowable bearing capacity of the soil is not exceeded. and <br />that differential settlement is minimized. The minimum <br />width of footings shall be 12 inches (305 mm). <br /> <br />Footings in areas with expansive soils shall be designed <br />in accordance with the provisions of Section 1805.8. <br /> <br />1805.4.1.1 Design loads. Footings shall be designed for <br />the most unfavorable effects due to the combinations of <br />loads specified in Section 1605,3. The dead load shall in- <br />clude the weight of foundations, footings and overlying <br />fill. Reduced live loads, as specified in Section 1607,9. <br />are pennitted to be used in designing footings, <br /> <br />1805.4,1.2 Vibratory loads. Where machinery opera- <br />tions or other vibrations are transmitted through the <br />foundation, consideration shall be given in the footing <br />design to prevent detrimental disturbances of the soil. <br /> <br />1805.4.2 Concrete footings, The design. materials and con- <br />struction of concrete footings shall comply with Sections <br />1805.4,2, I through 1805.4,2.6 and the provisions of Chap- <br />ter 19. <br /> <br />Exception: Where a specific design is not provided. con- <br />crete footings supporting walls of light-frame construc- <br />tion are pennitted to be designed in accordance with <br />Table 1805.4,2, <br /> <br />1805.4.2.1 Concrete strength. Concrete in footings <br />shall have a specified compressive strength if I c) of not <br />less than 2,500 pounds per square inch (psi) (17237 kPa) <br />at 28 days, <br /> <br />1805.4.2.2 Reserved. <br /> <br />SOILS AND FOUNDATIONS <br /> <br />1805,4,2,3 Plain concrete footings. The edge thickness <br />of plain concrete footings supporting walls of other than <br />light-frllJTle construction shall not be less than is Inches <br />(203 mrn) where placed on soil. <br /> <br />Exception: For plain concrete footings supporting <br />Group R-3 occupancies. the edge thickness is permit- <br />ted to be 6 inches (152 mm), provided that the footing <br />does not extend beyond a distance greater than the <br />thickness of the footing on either side of the supported <br />wall. <br /> <br />1805,4,2,4 Placement of concrete. Concrete footings <br />shall nC!,t be placed through water unless a tremie or otber <br />method approved by the building official is used. Where <br />placed under or in the presence of water, the concrete <br />shall be deposited by approved means to ensure mini- <br />mum segregation of the mix and negligible turbulence of <br />the water, <br /> <br />1805,4,2,5 Protection of concrete. Concrete footings <br />shall be protected from freezing during depositing and for <br />a period of not less than five days thereafter. Water shall <br />not be allowed to flow through the deposited concrete. <br /> <br />1805.4,2,6~orming of concrete. Concrete footings are <br />perffiitted to be cast against the earth where, in the opin- <br />iOD of the building official. soil conditions do not require <br />forming. Where forming is required, it shall be in accor- <br />dance with Chapter 6 ofACI 318. <br /> <br />1805,4,3 Masonry-unit footings. The design, materials <br />and construction of masonry-unit footings shall comply <br />with Sections 1805.4.3.1 and 1805.4.3,2, and the provisions <br />of Chapter 21, <br /> <br />Exception: Where a specific design is not provided, mo, <br />sonry-unit footings supporting walls of light-frame con- <br />struction are permitted to be designed in accordance with <br />Table 1805.4.2, <br /> <br />1805,4,3,1 Dimensions, Masonry-unit footings shall be <br />.Iaid in Type M or S mortar complying with Section <br /> <br />II <br /> <br />TABLE 1805.4.2 <br />FOOTINGS SUPPORTING WALLS OF WGHT.FRAME CONSTRUCTION-' b. c, d <br /> <br />.. WIDTH 011. ,. I <br /> THICKNESS OF <br />NUMBER OF FLOORS FOOTING FOOTING <br />SUPPORTED BY THE FOOTING' (Inoh..) (Inch..) <br />I 12 6 <br />2 15 6 <br />3 18 gf <br /> i <br /> <br />II <br /> <br />For SI: I inch = 25.4 mm, I foot = 304.8 mm. <br />u. Depth of footings shall be in accordance with Section 1805,2, <br />b. The ground under the floor is permitted to be excavated to the elevation of the top of the footing, <br />c. Interior-stud-bearing walls are permitted to be supported by isolated footings, The footing width and length shall be twice the width shown in this lable. and fool- <br />ings shall be spaced not more than 6 feel on center, <br />II d. For thickness of foundation walls, see Section 1805.5, <br />e. Footings are permitted to support aroofin addition to the stipulated number of floors, Footingssupporting roof only shall be as required for supporting one !loor <br />r. Plain concrete foolings for Group R-3 occupancies are permitted to be 6 incites thick, <br /> <br />FLORIDA BUILDING CODE - BUILDING <br /> <br />18.5 <br />