<br />FLORIDA ENERGY EFFICIENCY CODE
<br />FOR BUILDING CONSTRUCTION
<br />
<br />Florida Department of Community Affairs
<br />Residential Whole Building Performance Method A
<br />
<br />US1353SC- ST~ CROIX -1353 S.F. LIVING AREA Builder: U.~. HOMES ~
<br />LClZ61 \<'IAI-S\ e \4! _ ~Y)oa.e\ Permitting Office: C\~ o-C' Zep~d"\,\~S
<br />2ee~'( h\ l\C-j, ~l- Permit Number: 55t;5~ I
<br />US t-h.N"'Y\J2.- C..D' p. Jurisdiction Number: (..(i \ \(000 II
<br />Central ,
<br />
<br />H;~
<br />FORM 600A-2004
<br />
<br />..
<br />
<br />Project Name:
<br />Address:
<br />City, State:
<br />Owner:
<br />Climate Zone:
<br />
<br />I.
<br />2,
<br />3.
<br />4,
<br />5,
<br />6.
<br />7,
<br />
<br />New construction or existing New
<br />Single family or multi-family Multi-family
<br />Number of units, if multi-family 4
<br />Number of Bedrooms 3
<br />Is this a worst case? Yes
<br />Conditioned floor area (ft2) 1353 fP
<br />Glass type I and area: (Label reqd, by 13-104.4.5 if not default)
<br />a. U-factor: Description Area
<br />(or Single or Double DEFAULT) 7a(Sngle Default) 185.0 ft2
<br />b. SHGC:
<br />(or Clear or Tint DEFAULT)
<br />8. Floor types
<br />a, Slab-On-Grade Edge Insulation
<br />b, N/A
<br />c. N/A
<br />9, Wall types
<br />a. Concrete, Int Insul, Exterior
<br />b, Concrete, Int Insul, Adjacent
<br />c. N/A
<br />d. N/A
<br />e. N/A
<br />10. Ceiling types
<br />a, Under Attic
<br />b. N/A
<br />c. N/A
<br />II, Ducts
<br />I :: ~~~: Unc, Ret: Con, AH(Sealed):lnterior Sup, R=6,O, 150,0 ft
<br />Lb N/^
<br />
<br />7b,
<br />
<br />(Clear) 185,0 fP
<br />
<br />R=O,O, 103.0(p) ft
<br />
<br />R=4,1, 691.0 ft2
<br />R=4.1, 744,0 ft2
<br />
<br />R=19,0, 692,0 ft2
<br />
<br />lG::'/Floor Area: 0.14
<br />
<br />EnergyGauge@ 4.0
<br />
<br />12, Cooling systl;ms
<br />a. Central Unit
<br />
<br />Cap: 28,0 kBtulhr
<br />SEER: 12,00
<br />
<br />b, N/A
<br />
<br />c, N/A
<br />
<br />13. Heating systems
<br />a. Electric Heat Pump
<br />
<br />Cap: 30.0 kBtulhr
<br />HSPF: 7.80
<br />
<br />b, N/A
<br />
<br />c. N/A
<br />
<br />14, Hot water systems
<br />a, Electric Resistance
<br />
<br />Cap: 40.0 gallons
<br />EF: 0.92
<br />
<br />b. N/A
<br />
<br />c, Conservation credits
<br />(HR-Heat recovery, Solar
<br />DHP-Dedicated heat pump)
<br />15. HYAC credits
<br />(CF-Ceiling fan, CY-Cross ventilation,
<br />HF-Whole house fan,
<br />PT -Programmable Thermostat,
<br />MZ-C-Multizone cooling,
<br />MZ-H-Multizone heating)
<br />
<br />-,
<br />
<br />Total as-built points: 19573
<br />Total base points: 20957
<br />
<br />PAs~l
<br />
<br />
<br />Review of the plans and
<br />specifications covered by this
<br />calculation indicates compliance
<br />with the Florida Energy Code.
<br />Before construction is completed
<br />this building will be inspected for
<br />I hereby certify that this building, as designed, is in compliance compliance with Section 553.908
<br />with the Florida Energy Code. Florida Statutes. 4.... l
<br />
<br />OWNER/AGENT: BUILDING FF IAL: ~
<br />
<br />L DATE: DATE: . . 2- \; t..
<br />
<br />1 Predominant glass type, For actual glass type and areas, see Summer & Winter Glass out ut on pages 2&4.
<br />EnergyGauge@ (Version: FLRCSB v4,O)
<br />
<br />
|