Laserfiche WebLink
<br />~t; ~ <br /> <br />F-OR'M 600A-2004 <br /> <br />EnergyGauge@ 4.0 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br /> <br />Florida Department of Community Affairs <br />Residential Whole Building Performance Method A <br /> <br />US1353SC- ST. CROIX -1353 S.F. LIVING AREA Builder: U.S. HOMES <br />l.P2...4 \ .m~ Rd - ('node..\ 9 Permitting Office: Cd.~ Ob ~') t~'l r <br />,~"'-t-~ <=e- Permit Number: ~;.::>'1f <br />lLS \4c~ ) Jurisdiction Number: ~'l \ lOc:;O <br />Central <br /> <br />Project Name: <br />Address: <br />City, State: <br />Owner: <br />Climate Zone: <br /> <br />I. New construction or existing New <br />2. Single family or multi-family Multi-family <br />3. Number of units, if multi-family 4 <br />4. Number of Bedrooms 3 <br />5. Is this a worst case? Yes <br />6. Conditioned floor area (ft') 1353 ft, <br />7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) <br />a. U-factor: Description Area <br />(or Single or Double DEFAULT) 7a(Sngle Default) 185.0 ft, <br />b. SHGC: <br />(or Clear or Tint DEFAULT) <br />8. Floor types <br />a. Slab-On-Grade Edge Insulation <br />b. N/A <br />c. N/A <br />9. Wall types <br />a. Concrete, Int Insul, Exterior <br />b. Concrete, Int Insul, Adjacent <br />c. N/A <br />d. N/A <br />e. N/A <br />10. Ceiling types <br />a. Under Attic <br />b. N/A <br />c. N/A <br />II. Ducts <br />a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 150.0 ft <br />b. N/A <br /> <br />7b. <br /> <br />(Clear) 185.0 ft, <br /> <br />R=O.O, 103.0(p) ft <br /> <br />R=4.1, 691.0 ft, <br />R=4.1, 744.0 ft, <br /> <br />R=19.0, 692.0 ft, <br /> <br />12. Cooling systems <br />a. Central Unit <br /> <br />Cap: 28.0 kBtulhr <br />SEER: 12.00 <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />13. Heating systems <br />a. Electric Heat Pump <br /> <br />Cap: 30.0 kBtulhr <br />HSPF: 7.80 <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />14. Hot water systems <br />a. Electric Resistance <br /> <br />Cap: 40.0 gallons <br />EF: 0.92 <br /> <br />b. N/A <br /> <br />c. Conservation credits <br />(RR-Heat recovery, Solar <br />DHP-Dedicated heat pump) <br />15. HV AC credits <br />(CF-Ceiling fan, CV-Cross ventilation, <br />HF-Whole house fan, <br />PT -Programmable Thermostat, <br />MZ-C-Multizone cooling, <br />MZ.H-Multizone heating) <br /> <br />Glass/Floor Area: 0.14 <br /> <br />Total as-built points: 19573 <br />Total base points: 20957 <br /> <br />PASS=:=] <br /> <br /> <br />I hereby certify that this building, as designed, is in compliance <br />with the Florida Energy Code. <br /> <br />OWNER/AGENT: <br /> <br />DATE: <br /> <br /> <br />Review of the plans and <br />specifications covered by this <br />calculation indicates compliance <br />with the Florida Energy Code. <br />Before construction is completed <br />this building will be inspected for <br />compliance with Section 553.908 <br />Florida Statutes. <br />BUILDING <br /> <br />DATE: <br /> <br />1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass outpu on pa es 2&4. <br />EnergyGauge@ (Version: FLRCSB v4.0) <br /> <br />---.......... <br />. ..1.,'. <br />