<br />GENERAL ELECTRICAL NOTES: <br /> <br />1, ALL ELECTRICAL WORK SHALL CONFORM TO THE lATEST EDITION OF THE NATIONAL <br />ELECTRICAL CODE (NEC), ANO LOCAL CODES. <br /> <br />2. ALL ELECTRICAL MATERIALS, EQUIPMENT AND INSTALlATION PROCEDURES SHALL CONFORM <br />WITH T -MOBilE'S STANDARD CONSTRUCTION SPECIFICATIONS, <br /> <br />3, WIRE TO BE RATED AT 300 VOLTS ANO 105' C, ALL MATERIALS SHALL BE MANUFACTURED <br />IN ACCORDANCE WITH APPLICABLE STANDARDS ESTABLISHED BY ANSI, NEMA NFPA, AND "UL" <br />LISTED. <br /> <br />4, THE ELECTRICAL PlANS, DETAILS, AND DIAGRAMS SHOWN ON THESE DRAWINGS ARE <br />DIAGRAMMATIC ONLY. ACTUAL FIELD CONDITIONS AND SITE REQUIREMENTS SHALL DICTATE THE <br />AMOUNT AND LOCATION OF EQUIPMENT, <br /> <br />5. T'HE ENTIRE ELECTRICAL iNSTALlATION SHALL BE GROUNDED AS REQUIRED BY THE NEC <br />AND ALL APPLICABLE LOCAL CODES, <br /> <br />6. ALL CIRCUIT BREAKERS, FUSES AND ELECTRICAL EQUIPMENT SHALL HA~ A MINIMUM <br />INTERRUPTING RATING OF 65,000 AlC (UNLESS NOTED OTHERWISE), <br /> <br />7. PATCH, REPAIR ANO PAINT ANY AREA THAT HAS BEEN DAMAGED IN THE COURSE OF THE <br />ELECTRICAL INSTALlATION, <br /> <br />8. lABEL ALL ELECTRICAL EQUIPMENT PER T -MOBILE'S SPECIFICATIONS, <br /> <br />9, ALL INTERIOR CONDUITS ANO BUSHiNGS SHALL BE EMT, ALL EXTERIOR SHALL BE PVC <br />UNLESS NOTED OTHERWISE. <br /> <br />10. THE CONTRACTOR SHALL LOCATE AND MARK ALL EXISTING UNDERGROUNO POWER, TUCO, <br />GROUNDING CONDUITS, AND ALL DT'HER UTILITIES EASEMENTS AND/OR WIRES PRIOR TO <br />TRENCHING. ANY DAMAGE CAUSW TO THE EXISTING UNDERGROUND SERYlCES OR SYSTEMS <br />SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. <br /> <br />11, UTILITY RACK AND CONDUIT SIZES TO BE FIELD DETtRMINW BY CONTRACTOR iN <br />ACCORDANCE WITH THE LOCAL JURISDICTION. <br /> <br />12. MAINTAIN 3'-r:J' MINIMUM SEPARATION BETWEEN FUEl LINE AND ELECTRICAL LINES. <br /> <br />13. USE SCH 40 PVC CONDUIT BElOW GRADE AND USE SCH 80 PVC CONDUIT ABOVE GRADE. <br /> <br />~( 3T \: i\J::-:::; <br /> <br />"'.... <br /> <br /> <br />::.,3-,":' <br /> <br />',',t':- <br /> <br /> <br />(1) Z" PVC CONDUIT <br />(3) #2 AWG & (I) #4 FROM <br />METER TO ATS 0 GENERATOR <br /> <br />(1) Z" PYC CONDUIT W/ 3/4" <br />flEXIBLE COPPER FUEL LINE BY <br />FUEl SUPPLIER <br /> <br />(I) 3/4" PVC CONDUIT W/ (I) <br />4 PAIR 22 AWG CABLE <br />(IF APPliCABLE) <br /> <br /> <br />~l <br /> <br />::; <br />>= <br />:;;) <br />'" <br />w <br />a. <br /> <br />~ <br />W <br />D <br /> <br />~ " <br />~ ~ ~ <br />o @5:2: b <br />5 ~b 81 <br />~ !(~ <br />:!I ~ <br /> <br />SEE NOTE 2 <br /> <br />.ONE CALL" <br />SERYlCE SHALL BE <br />CALLED PRIOR TO <br />EXCAVATION <br /> <br />SLOPE TO SUIT SOIL <br />~ONDITION IN ACCORDANCE <br /> <br />SAND Bt:Df"NG PER <br />SITEWORK SPECIFICAflONS <br /> <br />POWER AND <br />AlARM CONDUITS <br /> <br />NOTES: <br />I, DETAIL SHOWN IS FOR ONE CONDUIT, MULTIPLE CONDUITS CAN BE <br />PlACED IN THE SAME TRENCH AS LONG AS A MINIMUM SEPARATION PER <br />THE LOCAL UTILITY COMPANIES IS MAINTAINED. IN ALL CASES THE <br />MINIMUM CENTER TO CENTER SPACING BETWEEN CONDUITS IS 1'-r:J'. <br />2. CONTRACTOR SHALL RESTORE THE TRENCH TO ITS ORIGINAL. CONDITIONS <br />BY SEEDING OR SOODING GRASS AREAS, OR REPlACING ASPHALT OR <br />CONCRETE AREAS TO THEIR ORIGINAL. CROSS SECTION, OR RESTORING <br />GRA ~L SURF ACES. <br />DETAIL A <br />TYPICAL UTILITY TRENCH <br />NO SCALE <br /> <br />NEW GENERATOR <br />W/ ATS <br /> <br />@ <br /> <br /> <br />L=", <br /> <br />DIRECn. Y <br />TO GROUND RING <br />(SEE G-I) <br /> <br />----------I <br /> <br /> <br />(1) Z" PVC CONDUIT W/ <br />(3) 3/0 AWG "" (I) '4 AWG FROI.l <br />GENERATOR TO T -MOBILE POWER PANEL <br /> <br />(1) 3/4" PYC CONDUIT W/(I) 8 <br />PAIR 22 AWG CABLE FRQI.l <br />GENERATOR TO T -MOBILE TELCO sex <br /> <br />DETAIL C <br />ELECTRICAL RISER DIAGRAM <br />NO SCALE <br /> <br />(Il 3/4" PVC CONDUIT W/(3l #18 <br />AWG FRQI.l GENERATOR TO <br />T -MOBILE POWER PANEL <br /> <br />----: <br /> <br />'.:] T-MC3 LE <br />:;\"~~I\i"- C.~2,\iET <br /> <br />~ <br /> <br /> <br />DETAIL B <br />STUB UP DETAIL @ T-MOBILE EQUIPMENT <br />NO SCALE <br /> <br />ABBREVIATIONS <br /> <br />- ~~:ST -.:, -_\,1~~_~ <br /> <br />A AMPERE <br />AIC AMPS INTERRUPTING CURRENT <br />AIR AMPS INTERRUPTING RATING <br />ATS AUTOMATIC TRANSFER S'MTCH <br />C CONDUI T <br />(E) EXISTING <br />G GROUND <br />K~ KILOWATT HOUR <br />(N) NEW <br />P PQE <br />ppe PO'IIER PROTECTION CABINET <br />SN SOliD NEUTRAL <br />SW S'M TCH <br />V VQT <br />W 'MRE <br />. PHASE <br /> <br />::;::;.:E <br /> <br />ENGINEER OF RECORD <br />CHRIS AlA~ KRAfFT <br />NO. 58906 <br />BlACK & YEA TCH <br />11401 LAMAR A~ <br />OVERlAND PARK, KS 66211 <br />(913) 458-2000 <br /> <br />CERTIFICATE OF AUTHORIZATION <br />CA 8132 <br /> <br />.T. · · Mobile.e <br /> <br />81 00 SW 10TH STREET <br />SUITE 1 000 <br />PLANTATION, Fl 33324 <br />PHONE: (954) 693-7100 <br />FAX: (954) 693-7200 <br /> <br />L J <br /> <br />a@ <br /> <br />BLACK & VEATCH <br />CORPORATION <br />114'01 LAMAR <br />OVERlAND PARK, KANSAS 66211 <br />(913) 458-2000 <br /> <br />PROJECT NO: <br />DRAWN BY: <br />CHECKED BY: <br /> <br />'44269 <br /> <br />cac <br />5S <br /> <br />04/' 7/06 ISSUEO FOR CONSTRUCTlON <br /> <br />REV <br /> <br />OAT!: <br /> <br />OESCRlPTKlN <br /> <br />~\~~/'" <br />1 ~ I. ~ <br />~<" ~,"/"V,"~~' '~,;.ri;~ <br />, ~. ~;U \ 4-.~, <br />, , 0 0 .-- <br />: :?' : Z Cl r,c! 0 " ;...-: <br />. : Q). W'-:-. <br />,: <{ . LU l() -~.... c:: <( : <br />I,~"O ," ~ o:~. <br />A.'~ 0 1-' '0 <br />",) Z , en <<-v.: " . <br />t.P '.~" ....' "J . <br />/ " " c, . <br />& J/A' ..,':.,' "~~<{, <br />y.I=!f.JJ~ <br /> <br />IT 1$ A VIOlATION Of LAW FOR ANY PERSON, <br />UNLESS THEY ARE ACTIN<;; UNDER THE DIRECTION <br />OF . UC'CNSEO PRQFESSlOl<W. ENCINEtR, <br />TO ..&LTtR THIS DOCUMENT. <br /> <br />T-MOBILE <br />POWER BACKUP <br />TAMPA I ORLANDO <br /> <br />SHEET TITLE <br /> <br />ELECTRICAL DETAILS <br /> <br />SHEET NUMBER <br /> <br />E-1 <br />