Laserfiche WebLink
<br />gradient, load intensity and erosion characteristics of slope <br />material. <br /> <br />1805.4 Footings. Footings shall be designed and constructed in <br />accordance with Sections 1805.4.1 through 1805.4,6. <br /> <br />1805.4,1 Design. Footings shall be so designed that the' <br />allowable bearing capacity of the soil is not exceeded, and <br />that differential settlement is minimized. The minimum <br />width of footings shall be 12 inches (305 mm). <br /> <br />Footings in areas with expansive soils shall be designed <br />in accordance with the provisions of Section 1805.8. <br /> <br />1805.4,1.1 Design loads. Footings shall be designed for <br />the most unfavorable effects due to the combinations of <br />loads specified in Section 1605.3. The dead load shall in- <br />clude the weight of foundations, footings and overlying <br />fill. Reduced live loads, as specified in Section 1607.9, <br />are permitted to be used in designing footings. <br /> <br />1805.4.1.2 Vibratory loads. Where machinery opera- <br />tions or other vibrations are transmitted through the <br />foundation, consideration shall be given in the footing <br />design to prevent detrimental disturbances of the soil. <br /> <br />1805.4,2 Concrete footings, The design, materials and con- <br />slruction of concrete footings shall comply with Sections <br />1805.4.2.1 through 1805.4.2.6 and the provisions of Chap- <br />ter 19. <br /> <br />Exception: Where a specific design is not provided, con- <br />crete footings supporting walls of light-frame construc- <br />tion are permitted to be designed in accordance with <br />Table 1805.4.2. <br /> <br />1805.4,2.1 Concrete strength. Concrete in footings <br />shall have a specified compressive strength (f I c) of not <br />less than 2,500 pounds per square inch (psi) (17237 kPa) <br />at 28 days. <br /> <br />1805.4.2,2 Reserved, <br /> <br />SOILS AND FOUNDATIONS <br /> <br />1805.4.2.3 Plain concrete footings. The edge lhlcknes, <br />of plain concrete footings supporting walls of other than <br />light-frame construction shall not be less than 8 Inches <br />(203 nun) where placed on soil. <br /> <br />Exception: For plain concrete footings supporting <br />Group R-3 occupancies, the edge thickness is permit- <br />ted to be 6 inches (152 mm), provided that the fOOling <br />does not extend beyond a distance grealer than the <br />thickness of the footing on either side of the supported <br />wall. <br /> <br />1805.4.2.4 Placement of concrete, Concrete footings <br />shall n<?t be placed through water unless a tremie or otber <br />method approved by the building official is used Where <br />placed under or in the presence of water, the concrete <br />shall be deposited by approved means to ensure mini- <br />mum segregation of the mix and negligible turbulence 01 <br />the water. <br /> <br />1805.4.2.5 Protection of concrete. Concrete foot! ngs <br />shall be protected from freezing during depOSiting and for <br />a period of not less than five days thereafter Water shall <br />not be allowed to flow through the deposited concrete <br /> <br />180~.4.2.6 Forming of concrete. Concrete foolings are <br />penriitted to be cast against the earth where, in the opi n- <br />ion of the building official, soil conditions do not require <br />fonning. Where fonning is required, it shall be in accor- <br />dance with Chapter 6 ofACI 318. <br /> <br />1805,4.3 Masonry-unit footings. The design. matel'lals <br />and construction of masonry-unit footings shall compl) <br />with Sections 1805.4.3.1 and 1805.4.3.2, and the prOYlslOI1~ <br />of Chapter 21. <br /> <br />Exception: Where a specific design is not prOVided. ma- <br />sonry-unit footings supporting walls of light-frame con- <br />struction are permitted to be designed in accordance with <br />Table 1805.4.2. <br /> <br />1805.4.3.1 Dimensions. Masonry-unit footings shall be <br />laid in Type M or S mortar complying with SeellOll <br /> <br />II <br /> <br />TABLE 1805.4,2 <br />FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTIONs, b. c, d <br /> <br />I WIDTH 01" . I <br /> , THICKNESS OF <br />NUMBER OF FLOORS FOOTING FOOTING <br /> SUPPORTED BY THE FOOTING' (Inoh..) (Inches) <br /> I 12 6 i <br /> 2 I <br /> 15 6 I <br />I 3 18 8f , <br /> I <br /> <br />II <br /> <br />For 51 I inch = 25.4 mm, I foot = 304.8 mm. <br />" Depth of footings shall be in accordance with Section] 805.2. <br />b. The ground under the floor is permitted to be excavated to the elevation of the top of the footing. <br />c. Interior-srud-bearing walls are permitted to be supported by isolated footings. The footing width and length shall be twice the width shown in thiS table. aile! 10lll. <br />ings shall be spaced not more than 6 feet on center. <br />II d. For thickness of foundation walls, see Section 1805.5. <br />e Footings are permitted to support a roofin addition to the stipulated number of floors. Footings supporting roof only shall be as required for supporting one 11001 <br />r Plain concrete footings for Group R,3 occupancies are pennitted to be 6 incites thicl" <br /> <br />FLORIDA BUILDING CODE - BUILDING <br /> <br />185 <br />