<br />.. <br />~ <br /> <br />Architectural Testing <br /> <br />62609.01-501-47 <br />Page 4 of 10 <br /> <br />Test Specimen Description: (Continued) <br /> <br />Drainage: <br /> <br />Description Quantity <br /> <br />Location <br /> <br />22 mm (7/8") wide by 2 <br />4.7 mm (3/16") high weepslot <br />(with flap) <br /> <br />Exterior face of sill, one at <br />each end <br /> <br />32 mm (1-114") wide by 2 <br />12.7 mm (112") deep weepslot <br /> <br />SilVjamb intersection, one at each <br />end <br /> <br />25 mm (1") wide by 2 <br />4.7 mm (3/16") high weepslot <br /> <br />19.0 mm (3/4") wide by 2 <br />4.7 mm (3/16") deep weepslot <br /> <br />Intermediate sill wall, one at <br />each end <br /> <br />Sill screen track, one at <br />each end <br /> <br />9.5 mm (3/8") wide by 4 <br />3.2 mm (118") deep weepslot <br /> <br />Bottom sash rail and exterior <br />meeting rail, one at each end <br /> <br />Reinforcement: The lock rail contained a custom shaped, formed steel reinforcement <br />measuring 22.2 mm by 11.7 mm by 1.2 mm (0.875" by 0.461" by 0.047"), reference <br />Drawing No. UY0095. The keeper rail and bottom rail contained a custom shaped, formed <br />steel reinforcement measuring 11.7 rom by 12.0 mm by 1.5 rom (0.875" by 0.473" by <br />0.059"), reference Drawing No. UY0094. <br /> <br />Installation: The unit was installed in a wood buck constructed of Spruce-Pine-Fir <br />construction lumber and secured through the jambs to the buck using four #8 x 64 nun <br />(2-112") long screws, one at the top and bottom of each jamb. The exterior and interior <br />perimeter was sealed with a silicone sealant, with the exception of an approximate 102 nun <br />(4") long void at each,interior sill comer. A nominal 5 mm (3/16") gap was maintained at <br />the perimeter between the buck and window frame. <br />