<br />APPENDIX 13-D
<br />
<br />SUMMER POINT MULTIPLIERS (SPM)
<br />6A-l SUMMER OVERHANG FACTORS (SOF) FOR SINGLE AND DOUBLE-PANE GLASS
<br />
<br />CLIMATE ZONES 4 5 6
<br />
<br /> OHR8lio ,00-.11 .12-.17 ,18-.26 .27-.35 .36-.46 .47-.57 .58-.70 ,71-.83 ,84-1.18 1,19-1.72 1.73-2,73 2.74 & up
<br />J North 1.00 0,992 0,971 0,931 0,891 0,848 0,811 0,776 0,748 0,695 0,651 0,611
<br />Northeast 1.00 0,995 0,966 0,908 0,846 0,777 0,719 0,665 0,623 0,549 0,491 0,445
<br />m East 1,00 0,993 0,964 0,903 0,835 0,755 0,687 0,622 0,571 0,482 0,414 0,463
<br />I-a: Southeast . 1.00 0,999 0,956 0,871 0,786 0,700 0,635 0,580 0,540 0,478 0,436 0,407
<br />lrlO
<br />1 South 1,00 0,988 0,935 0,849 0,776 0,708 0,659 0,618 0,588 0,539 0,503 0,475
<br />Southwest 1,00 0,997 0,956 0,874 0,793 0,709 0,645 0,588 0,547 0,479 0.431 0,396
<br />Weat 1,00 0,994 0,964 0,902 0,834 0,757 0,691 0,630 0,582 0,500 0.438 0,391
<br />Northwest 1,00 0,995 0,966 0,911 0,857 0,798 0,751 0,708 0,674 0,616 0,570 0,532
<br />OH Length 0.0' 1.0' 1.5' 2,0' 3,0' 3,5' 4,5' 5,5' 6.5' 9.5' 14.0' 20,0'
<br />
<br />6A-2 WALL SUMMER POINT MULTIPLIERS (SPM)
<br />
<br /> CONCRETEBLOCK(NORMAL~ FACE BRICK
<br /> FRAME R-VALUE WDOD FR R-VALUE BLOCK LOG
<br /> INTERIOR EXT,
<br /> WOOD STEEL INSULATION INSUL. 0-jl,9 2,9 0-2,9 1,0 6 INCH 8 INCH
<br />R-VALUE EXT ADJ EXT ADJ R-VALUE EXT ADJ EXT 7-10,9 ,6 3-6,9 ,6 R-VALUE EXT EXT
<br />0-6,9 6.4 2,2 8,9 2,9 0-2,9 2,5 ,9 2,5 11-18,9 ,4 7-9,9 .4 0-2,9 1,7 1.0
<br />7-10,9 2,3 ,8 4,1 1,3 ~,9 1.4 ,7 .7 19-25,9 ,2 10& UP ,2 3-jl,9 1,1 ,8
<br />11-12,9 1.9 ,7 3,0 1.0 5-6,9 1,0 ,6 ,3 26 & UP .1 7& UP ,8 ,7
<br />13-18,9 1.7 ,6 2,8 0,9 7-10,9 .8 .4 ,1
<br />19-25,9 1,0 ,3 2,4 0.8 11-18,9 .4 .3 0
<br />26 & UP .6 ,2 1,3 0.4 19-25,9 ,2 ,2
<br /> 26 & Up ,1 ,1 I ~~~~L~~~ ~~~~~T~N~:6~~~]~ ~~M~ULTIPLlERS OF I
<br />
<br />
<br />6A-4 CEILING SUMMER POINT MULTIPLIERS (SPM)
<br />UNDER ATTIC SINGLE ASSEMBLY
<br />R-VALUE SPM R-VALUE SPM
<br />19-21,9 2,82 10-10,9 10,27
<br />22-25.9 2,55 11-12,9 9,73
<br />26-29.9 2,28 13-18,9 8,72
<br />30-37,9 2,13 19-25,9 6,90
<br />38 & UP 1.84 26-29,9 5,82
<br />RSS Credit 0.700 30 & Up 5.40
<br />IRCC Credit 0,864
<br />WMe Roof Credit 0 550
<br />
<br />R-VALUE
<br />
<br />CONCRETE DECK ROOF
<br />CEILING TYPE
<br />EXPOSED DROPPED
<br />11.13 10,40
<br />8.42 7,99
<br />
<br />10-13,9
<br />14-20,9
<br />
<br />21 & UP
<br />
<br />5,99 5,76
<br />
<br />6A-5 FLOOR SUMMER POINT
<br />SLAB-ON-GRADE RAISED RAISED WOOD
<br />EDGE INSULATION CONCRETE POST OR PIER STEM WALL w/UNDER ADJACENT
<br /> CONSTRUCTION FLOOR INSULATION
<br />R-VALUE SPM R-VALUE SPM R-VALUE SPM SPM SPM
<br />0-2,9 -31.9 0-2,9 -1.0 0-jl,9 4,50 -5,8 5,3
<br />3-4,9 -31.8 3-4,9 -1.7 7-10,9 2,28 -2,8 2,1
<br />5-6,9 -31,7 5-6.9 .1.7 11-18,9 1.83 -2,2 1.8
<br />7& UP -31.6 7& UP -1.7 19&UP 1,36 -1.8 1,0
<br />
<br />
<br />6A-8 DUCT MULTIPLIERS (OM) ... .....'..IO,,,.8C.2.1 '" ~ mlnkn_,
<br />
<br /> DUCT RETURN DUCTS In:
<br /> SUPPLY DUCTS IN: R-VALUE Unconditioned AtUc/ AtUc/ AtUc/ Condlltoned
<br /> space RBS IRCC White roof aoace
<br /> 4,2 1,113 1,107 1,108 1.107 1,103
<br /> Unconditioned Space 6,0 1,087 1,081 1,083 1.081 1,079
<br />Located in garage 1,00 8,0 1.069 1,064 1,065 1.064 1,062
<br /> 0,90 42 1,072 1.066 1,061
<br />Located in conditioned area
<br />Located on exterior 01 bulldino 1.02 AtticlRadiant Barrier (RBS) 6,0 1.056 1.051 - - 1,047
<br />Located in attic 1,10 8.0 1,045 1,041 1,038
<br /> 4,2 1.098 1.092 1.084
<br /> Atticl1nterior Radiation Control 6,0 1.076 - 1,071 - 1.065
<br /> Coatings (IRCC)
<br /> 8,0 1,060 - 1,057 - 1.052
<br /> 4,2 1,069 - - 1,063 1.058
<br /> AtticJWhite Roof 6,0 1,052 - - 1.047 1.044
<br /> 8,0 1.041 - - 1,037 1.034
<br /> 4,2 1,006 1,005 1.007 1,003 1.000
<br /> Conditioned Space 6,0 1.005 1.004 1,005 1.002 1.000
<br /> 8,0 1,004 1,003 1,004 1.002 1.000
<br />SYSTEM TYPE &..TtIb1etU07.U,BC.UA.RDlorcodllrnmtmumll COOLING SYSTEM MULTIPLIERS (CSMI
<br /> Ratina 7,5-7,9 8,0-8,4 8,5-8,8 8,9-9,4 9,5-9.9 10,0-10.4 10,5-10,9 11.0-11,4 11,5-11.9 12,0-12,4
<br />Central Units (SEER) SM ,45 ,43 ,40 ,38 ,38 ,34 ,32 ,30
<br /> ,31 ,28
<br /> Ratina 12.5-12,9 13,0-13.4 13,5-13,9 14,0-14,4 14,5-14,9 15,0-15.4 15,5-15,9 16,0-16,4 16,5-16,9 17,0-17,4 17,5 & UP
<br />PTAC & Roam Units (EER) CSM ,27 ,26 ,25 ,24 ,24 ,23 ,22 ,21 ,20
<br /> ,21 ,19
<br />
<br />6A-7 AIR HANDLER MULTIPLIERS (SPM)
<br />
<br />6A-9 COOLING SYSTEM MULTIPLIERS (CSM)
<br />
<br />FLORIDA BUILDING CODE - BUILDING
<br />
<br />Page 3
<br />13-D.17