My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
06-5879
Zephyrhills
>
Building Department
>
Permits
>
2006
>
06-5879
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:19:17 PM
Creation date
6/6/2007 11:38:47 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
06-5879
Building Department - Name
GRAND HORIZON
Address
37527 GILL AV LOT 279
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />. . <br /> <br />gradient, load intensity and erosion characteristics of slope <br />material. <br /> <br />1805.4 Footings. Footings shall be designed and constructed in <br />accordance with Sections 1805.4.1 through 1805.4.6. <br /> <br />1805.4,1 Design. Footings shall be so designed that the <br />allowable bearing capacity of the soil is not exceeded, and <br />that differential settlement is minimized. The minimum <br />width of footings shall be 12 inches (305 mm). <br /> <br />Footings in areas with expansive soils shall be designed <br />in accordance with the provisions of Section 1805.8. <br /> <br />1805.4.1.1 Design loads. Footings shall be designed for <br />the most unfavorable effects due to the combinations of <br />loads specified in Section 1605.3. The dead load shall in- <br />clude the weight of foundations, footings and overlying <br />fill. Reduced live loads. as specified in Section 1607.9. <br />are permitted to be used in designing footings. <br /> <br />1805.4.1.2 Vibratory loads, Where machinery opera- <br />tions or other vibrations are transmitted through the <br />foundation, consideration shall be given in the footing <br />design to prevent detrimental disturbances of the soil. <br /> <br />1805.4.2 Concrete footings. The design, materials and con- <br />struction of concrete footings shall comply with Sections <br />1805.4.2.1 through 1805.4.2.6 and the provisions of Chap- <br />ter 19. <br /> <br />Exception: Where a specific design is not provided, con- <br />crete footings supporting walls of light-frame construc- <br />tion are permitted to be designed in accordance with <br />Table 1805.4.2. <br /> <br />1805.4.2.1 Concrete strength. Concrete in footings <br />shall have a specified compressive strength (f I,) of not <br />less than 2,500 pounds per square inch (psi) (17237 kPa) <br />at 28 days. <br /> <br />1805.4.2.2 Reserved. <br /> <br />SOILS AND FOUNDATIONS <br /> <br />1805.4.2.3 Plain concrete footings. The edge thickness <br />of plain concrete footings supporting walls of other than <br />light-frame construction shall not be less than 8 i I1ches <br />(203 mm) where placed on soil. <br /> <br />Exception: For plain concrete footings supporting <br />Group R-3 occupancies, the edge thickness is permit- <br />ted to be 6 inches (152 mm), provided that the footing <br />does not extend beyond a distance greater than the <br />thickness of the footing on either side of the supported <br />wall. <br /> <br />1805.4.2.4 Placement of concrete. Concrete foolings <br />shall nq,t be placed through water unless a tremie or olber <br />method approved by the building official is used. Where <br />placed under or in the presence of water, the concrete <br />shall be deposited by approved means to ensure mini- <br />mum segregation of the mix and negligible turbulence 01 <br />the water. <br /> <br />1805.4.2.5 Protection of concrete. Concrete footing, <br />shall be protected from freezing during depositing and f'or <br />a period of not less than five days thereafter. Water shall <br />not be allowed to flow through the deposited concrete. <br /> <br />1805.4.2.6}?orming of concrete. Concrete foolings are <br />penriitted to be cast against the earth where, in the opin- <br />ioo'ofthe building official. soil conditions do not require <br />fonning. Where fanning is required. it shall be in accor- <br />dance with Chapter 6 of ACI 318. <br /> <br />1805.4.3 Masonry-unit footings. The design, materials <br />and construction of masonry-unit footings shall campi) <br />with Sections 1805.4.3.1 and 1805.4.3.2, and the provisions <br />of Chapter 21 . <br /> <br />Exception: Where a specific design is not provided, ma- <br />sonry-unit footings supporting walls of light-frame con- <br />struction are permitted to be designed in accordance IV i t h <br />Table 1805.4.2. <br /> <br />1805.4.3.1 Dimensions. Masonry-unit footings shall be <br />laid in Type M or S mortar complying with Section <br /> <br />II <br /> <br />TABLE 1805.4.2 <br />FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION.' b, c, d <br /> <br />I WIDTH 01" . THICKNESS OF I <br />NUMBER OF FLOORS FOOTING FOOTING <br /> SUPPORTED BY THE FOOTING' (Inoh..) (Inchea) <br /> I 12 6 <br /> 2 15 6 <br /> 3 18 8f <br /> <br />II <br /> <br />For 51: I inch = 25.4 mm, I foot = 304.8 mm.. <br />d Depth of footings shall be in accordance with Section J 805.2. <br />b The ground under the floor is permitted to be excavated to the elevation of the top of the footing. <br />c Interior-stud-bearing walls are permitted to be supported by isolated footings. The footing width and length shall be twice the width shown 10 this table. and IOO!' <br />ings shall be spaced not more than 6 feel on center. <br />II d. For thickness of foundation walls. see Section 1805.5. <br />e. Footings are permitted to support a roofin addition to the stipulated number of floors. Footings supporting roof only shall be as required for supponlng one Iloor <br />f Plain concrele footings for Group R-3 occupancies are permitted to be 6 inclres thick. <br /> <br />FLORIDA BUILDING CODE - BUILDING <br /> <br />18.5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.