Laserfiche WebLink
<br />gradient, load intensity and erosion characteristics of slope <br />material. <br /> <br />1805.4 Footings. Footings shall be designed and constructed in <br />accordance wi th Sections 1805.4.1 through 1805.4.6. <br /> <br />1805.4.1 Design. Footings shall be so designed that the. <br />allowable bearing capacity of the soil is not exceeded. and <br />that differential settlement is minimized. The minimum <br />width of footings shall be 12 inches (305 mm). <br /> <br />Footings in areas with expansive soils shall be designed <br />in accordance with the provisions of Section 1805.8, <br /> <br />1805.4.1.1 Design loads. Footings shall be designed for <br />the most unfavorable effects due to the combinations of <br />loads specified in Section 1605.3. The dead load shall in- <br />clude the weight of foundations, footings and overlying <br />fill. Reduced live loads. as specified in Section 1607.9, <br />are permitted to be used in designing footings. <br /> <br />1805.4,1.2 Vibratory loads. Where machinery opera- <br />tions or other vibrations are transmitted through the <br />foundation, consideration shall be given in the footing <br />design to prevent detrimental disturbances of the soil. <br /> <br />1805.4.2 Concrete footings. The design, materials and con- <br />struction of concrete footings shall comply with Sections <br />1805.4.2.1 through 1805.4.2.6 and the provisions of Chap- <br />ter 19. <br /> <br />Exception: Where a specific design is not provided. con- <br />crete footings supporting walls of light-frame construc- <br />tion are permitted to be designed in accordance with <br />Table 1805.4.2. <br /> <br />1805,4.2.1 Concrete strength, Concrete in footings <br />shall have a specified compressive strength if I c) of not <br />less than 2,500 pounds per square inch (psi) (17237 kPa) <br />at 28 days. <br /> <br />1805.4.2.2 Reserved. <br /> <br />SOILS AND FOUNDATIONS <br /> <br />1805.4.2.3 Plain concrete footings. The edge thickness <br />of plain concrete footings supporting walls of other than <br />light-frame construction shall not be less than 8 Illches <br />(203 mm) where placed on soil. <br /> <br />Exception: For plain concrete footings supporting <br />Group R-3 occupancies. the edge thickness is permll- <br />ted to be 6 inches (152 mm), provided that the fOOling <br />does not extend beyond a distance greater than the <br />thickness of the footing on either side of the supported <br />wall. <br /> <br />1805.4.2.4 Placement of concrete. Concrete footings <br />shall not be placed through water unless a tremie or other <br />methocf approved by the building official is used. Where <br />placed under or in the presence of water, the concrete <br />shall be deposited by approved means to ensure mini- <br />mum segregation of the mix and negligible turbulence at <br />the water. <br /> <br />1805.4.2.5 Protection of concrete. Concrete fooll ngs <br />shall be protected from freezing during depositing ancl for <br />a period of not less than five days thereafter. Water shall <br />not be allowed to flow through the deposited concrete <br /> <br />1805.4.2.6 Forming of concrete. Concrete footings are <br />perrriitted to be cast against the earth where, in the opin- <br />ion of the building official, soil conditions do not requl re <br />fonning, Where fonning is required, it shall be in accor- <br />dance with Chapter 6 ofACI 318, <br /> <br />1805.4.3 Masonry-unit footings. The design, matenals <br />and construction of masonry-unit footings shall comply <br />with Sections 1805.4.3.1 and 1805.4.3.2, and the provisions <br />of Chapter 21. <br /> <br />Exception: Where a specific design is not provided, ma- <br />sonry-unit footings supporting walls of light-frame con- <br />struction are permitted to be designed in accordance with <br />Table 1805.4.2, <br /> <br />1805.4.3.1 Dimensions. Masonry-unit footings shall be <br />.laid in Type M or S mortar complying with Seclion <br /> <br />II <br /> <br />TABLE 1805.4.2 <br />FOOTINGS SUPPORTING WALLS OF LIGHT.FRAME CONSTRUCTIONa, b, c, d <br /> <br />r <br /> WIDTH OP . THICKNESS OF <br />NUMBER OF FLOORS FOOTING FOOTING <br />SUPPORTED BY THE FOOTING" (Inoh..) (Inch.a) <br />1 12 6 <br />2 15 6 <br />3 18 8f I <br />I <br /> <br />II <br /> <br />For 51: I inch = 25.4 mm, I foot = 304.8 mm.. <br />d Depth of footings shall be in accordance with Section J 805.2. <br />b The ground under the floor is permitted to be excavated to the elevation of the top of the footing. <br />c. Interior-stud-bearing walls are permilted to be supported by isolated footings. The footing width and length shall be twice the width shown in this table. and fool- <br />ings shall be spaced not more than 6 feet on center. <br />II d. For thickness of foundation walls, see Section 1805.5. <br />e Footings are permilted to suppon a roof in addition to the stipulated number of floors. Footings supponing roof only shall be as required for supponing one !loor <br />r Plain concrete footings for Group R-3 occupancies are permitted to be 6 incites thick. <br /> <br />FLORIDA BUILDING CODE - BUILDING <br /> <br />18.5 <br />