My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
06-6040
Zephyrhills
>
Building Department
>
Permits
>
2006
>
06-6040
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:18:28 PM
Creation date
6/8/2007 10:20:00 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
06-6040
Building Department - Name
SLOAN,MARLA
Address
5648 12TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />.~ <br /> <br />... <br /> <br /> <br />C-BUCK Engineering <br /> <br />FL #: FL 5818.1 <br />I>ate: 11/14/05 <br />Report No.: 05-284-R-36-S6W <br />Page 20f5 <br /> <br />Specialty Structural Engineering <br /> <br />C-Buck. Inc., FL Cert. of Authorization # 8064 <br /> <br />Manufacturer: <br /> <br />Corrugated Industries of Florida, Inc. <br /> <br />Product Name: <br /> <br />R-Panel and PBR Panel <br />Steel, minimum 26 gauge, minimum yield strength 50 ksi <br /> <br />Panel Type: <br /> <br />Panel Material <br />Standards: <br />Panel Width(s) <br /> <br />Material shall comply with Table 1507.4.3 <br /> <br />36" Maximum (Net Coverage Width) <br /> <br />Support Type: <br /> <br />Wood Deck <br />(Design of support system is not included in this evaluation) <br /> <br />Plywood -15/32" or greater, or wood plank per Section 2308.10.8 <br /> <br />Support Description: <br /> <br />Slope Range: <br /> <br />3 : 12 or greater <br /> <br />Design Uplift Pressure: <br /> <br />52.5 psf ( Safety Factor of 2: 1 ) <br /> <br />Attachment To Support: Panels shall be attached to the deck with minimum. #10 X minimum <br />penetration through deck 3/16", hex-head, self-tapping, corrosion <br />resistant, wood screws, per ANSIIASME B18.6.4 with a 5/8" OD <br />formed steel washer and a neoprene sealing washer. <br /> <br />Underlayment: Minimum underla}rment shall be per Section 1507.4.5 <br /> <br />Insulation: (Optional) - Any. compressible blanket insulation maximum 6" thick <br />before compression. <br /> <br />Fire Classification: Fire Classification is outside the scope of Rule 9B-72, and is therefore not <br />included in this evaluation. Additional approved substrates may be added <br />for Fire Classification purposes. <br /> <br />Installation: Install the "R-Panel and PBR Panel" to the deck with a fasteners <br />spaced 3" from an ends and maximum 16" o.c. thereafter, along the <br />length of the panel. Within rows, fasteners shall be spaced maximum <br />12" o.c. across the width of the panel, beginning 2-1/2" from the <br />center line of each major corrugation. Panel laps shall be stitched 3" <br />from all ends and marlmum 20" o.c. thereafter, along the length of <br />the lap, at the top of the major corrugation, with mi.nimum #12-14 x <br />minimum penetration %", hex-bead, self-<lriUing, corrosion resistant, <br />sheet metal screws, per SAE J78-1979 with a 5/8" OD formed steel <br />washer and a neoprene sealing washer. Install system in compliance <br />with the attached installation method. <br />
The URL can be used to link to this page
Your browser does not support the video tag.