My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
06-6139
Zephyrhills
>
Building Department
>
Permits
>
2006
>
06-6139
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:17:57 PM
Creation date
6/19/2007 11:49:15 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
06-6139
Building Department - Name
CITY OF Z-HILLS
Address
3940 SOUTH AV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br />Wiring Diagram GE3 Series with Gentex Synchronization Module <br /> <br />..."".... <br />-- <br />..... <br />-.GONLY. <br /> <br /> <br />-----------.--------.-----., <br />, <br /> <br /> <br />TO NEXT SIGNAL <br /> <br />TO NOTIFICATION Al.ARM OROJIT <br /> <br />AUDlBLEIIBNAL + <br />CIRClIIT <br /> <br />LEAVE JUIIPER IN PLACE ON <br />SlAVE UNITS UNLESS SEPARATE <br />CONTROL OVER HORN CKT <br />IS REQUtRED. <br /> <br />'MIBLE_ + <br />CIRCUIT <br /> <br />SID Of UNE <br />........ - <br />.... . <br />_COlO.Y <br /> <br /> <br />~====::=~:rt=__:==__=~===_==__=_=__==~===_j <br /> <br />Note: See Technical Bulletin 015 for proper synchronization module for application. <br />Note: When synchronizing the GE3 12 VDC Series, the AVSM synchronization module M.USI be used. <br /> <br />Architect & Engineering Specifications: <br />The audible and'or visible signal shall be Gentex GE3 Series or approved equal and shall be listed by Underwriters Laboratories Inc. per UL <br />1971 and/or UL 464. The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals <br />(NYC). <br />The notification appliance (combination audiblelvisible) shall produce a peak sound output of 1 OOdBA or greater at 12 or 24V as measured in an ane- <br />choic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of <br />a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the abil- <br />ity to be synchronized. <br />Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm <br />control panel. <br />The audiblelvisible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2 Hz regardless of power input voltage. <br />The appliance shall have an operating current of 55mA or less at 24 VDC for the 15Cd strobe circuit and 106mA or less at 12 VDC for the 15Cd strobe circuit. <br />The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with termi- <br />nals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. <br />The unit shall have an input voltage range of 1 &33 volts with either direct current of full wave rectified power for 24 volt models or a voltage range of 8-17.5 <br />volts for 12 volt models. <br />The appliance shall be capable of testing supervision without disconnecting wires. Also the appliance shall be capable of mounting to a surface back <br />box. The unit shall also be able to verify voltage at the unit without removing unit. <br /> <br /> <br />GENTEX <br />CORPORATION <br /> <br />Important Notice: <br /> <br />These matertaas have been prepared by Gentsx Corporation rOente)(") for i"lformational purposes only, are <br />necessarfy summary, and are n01 purported to serve as ~a1 advice and should not be used as such. <br />Gent_ makes no representations and warranties, express or Impied, that these materials are compiete <br />and accurate, up-to-date, or in compliance with al relevant 500a1. sta18 and federal laws, regulations and <br />nJes. The materials do not address al legal considerations as there is inevitable U"lcertainty regarding <br />int8fJ)f8ta.t1on of laws, regulations and rulllS and the application of such laws, regu"lIons and rules to partic- <br />ular fact p8~S. Each person's actMttes can differen1ty affect '\he obligations that exist under applicable <br />~, regutatlons or nAes. Therefore. these materials should be used only for informational purposes and <br />should not be used as B substitute tor seeking protessianallegal advice. Gentex will not be responsibte for <br />any action or failure to act in ralence upon the information contained in this material. <br /> <br />551-0050-02 <br /> <br />Fire Protection Products: www.gentex.com <br />10985 Chicago Drive Box 310 . Zeeland, Michigan 49464 <br />616.3927195 . 1.800.436.8391 · 616.392.4219 Fax <br /> <br />Gentex corporation reSefVe.!i t.he right to make change50 \0 the produl:t data shffb i1t their dis.cretion <br /> <br />U Printed on Recycled Paper <br />
The URL can be used to link to this page
Your browser does not support the video tag.