My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
06-6258
Zephyrhills
>
Building Department
>
Permits
>
2006
>
06-6258
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:17:15 PM
Creation date
6/21/2007 8:37:22 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
06-6258
Building Department - Name
WEBER,RONALD
Address
4825 17TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />15i ASPHALT FELT <br />UNDERLAYMENT <br /> <br />METAL DRIP EDGE AT RAKE <br />APPLIED OVER UNDERLAYMENT <br /> <br /> <br />METAL DRIP <br />APPLIED <br />OVER SHEATHING <br /> <br />ROOF SHEATHING NAIL INTERIOR <br />ael NAILS <RINGSHANK> 6' O,C, <br /> <br />ROOF SHEATHING NAIL @ EDGES <br />ad NAILS <RINGSHANK> 4' O,C, <br /> <br />USE ONLY ENOUGH NAILS TO HOLD <br />UNDERLAYMENT IN PLACE UNTIL <br />SHINGLES ARE LAID <br /> <br />--- <br />--- <br />--- <br />--- <br />--- <br /> <br />--- <br />--- <br />--- <br />--- <br />--- <br />--- <br /> <br />ASPHALT CEMENT <br /> <br />ROOF UNDERLAYHENT APPLICATION <br /> <br />TYPICAL FOR GAF/LANDMARK SHINGLES ETC <br /> <br />1. ROOF COVERINGS SHALL BE APPLIED IN ACCORDANCE 'WITH <br />THE APPLICABLE PROVISIONS OF SECTION 1507 FBC, 2001 <br /> <br />2, FOR ROOF SLOPES 212 UP TO 412 UNDERLAYMENT SHALL BE <br />A MINIMUM OF 2 LAYERS APPLIED AS FOLLO'WS: (SEE ABOVE) <br />FBC 15073,81 <br /> <br />3 FOR ROOF SLOPES 412 DR GREATER UNDERLAYMENT SHALL BE A <br />MINIMUM OF ONE LAYER OF UNDERLAYMENT FELT APPLIED AS FOLLO'WS: <br />STARTING AT THE EAVE UNDERLAYMENT SHALL BE APPLIED SHINGLE <br />FASHION PARALLEL TO THE EAVE, LAPPED 2' AND FASTENED <br />SUFFICIENTL Y TO STAY IN PLACE UNTIL SHINGLES ARE LAID, <br />FBC 15073,82 <br /> <br />4, DRIP EDGE: DRIP EDGE SHALL BE PROVIDED AT EAVES AND GABLES <br />OF SHINGLE ROOFS AND OVERLAPPED A MINIMUM OF 2 INCHES <br />EAVE DRIP EDGES SHALL EXTEND 1/4' BELO'W SHEATHING AND EXTEND <br />BACK ON THE ROOF A MINIMUM OF 2 INCHES DRIP EDGE SHALL BE <br />MECHANICALLY FASTENED A MAXIMUM OF 12' ON CENTER <br />FBC 1507383 <br /> <br />PL YwOOD NAILED AS SHOwN IS DESIGNED TO wITH STAND <br />MAXIMUM wIND LOAD RATING OF 130 MPH wITH FASTEST SPEED OF 110 <br /> <br />15/32/1 CDX SHEA THING SHALL BE NAILED w / 8d RS NAILS @ 6" D,C, <br />@ E D G E SAN D 8 II 0, C , M A X , I NTH E FIE L D, USE 1 /2/' S TEE L PLY C L I pl S, <br /> <br /> <br />STEEL_ PL YCLIPS <br /> <br />3dl RS NAILS <br /> <br /> <br />1,1 II 1'1 <br />II I II <br />1,1 1'1 <br /> I II I <br />1:1 II <br />II I 'I <br />I <br />II I II <br />II II <br />1'1 II II <br />II I Jj <br />I <br />1'1 ~ II ~ II <br />ICO II COI <br />I'IT 1'1 TI'I <br />II II II <br />1'1 1'1 1'1 <br /> I II I <br />1'1 1,1 <br />I' 1'1 'I <br /> I 1.1 I <br />II II <br />II II II <br />II 1,1 II <br />II II II <br />I 1.1 -tl.- <br />I' II <br />II I <br />1'1 II 1'1 <br />II II <br />1,1 1'1 <br /> I I I <br />1,\ 1.1 <br />I' II 'I <br /> I I <br />1.1 I 1,1 <br />II II <br />I" II 1.1 <br /> <br /> <br />PL Y\JODD NAIL PATTERN (ROOF) <br /> <br /> <br />9' STARTER STRIP DR <br />COURSE OF INVERTED <br />SHINGLES <br /> <br />15~ ASPHALT FELT <br />UNDERLAYMENT <br /> <br />.. <br /> <br />METAL DRIP EDGE <br />AT RAKE APPLIED <br />OVER UNDERLAYMENT <br /> <br />START THIRD COURSE 'WITH <br />FULL STRIP MINUS FIRST <br />TAB <br /> <br />START SECOND COURSE <br />'WITH FULL STRIP MINUS <br />1/2 TAB <br /> <br />START FIRST COURSE 'WITH <br />FULL STRIP <br /> <br />ROOFING APPLICATION <br /> <br />1. ROOF COVERINGS SHALL BE APPLIED IN ACCORDANCE 'WITH THE <br />APPLICABLE PROVISIONS OF SECTION 1507 FEC AND THE <br />MANUFACTURERS INSTALLATION INSTRUCTIONS, <br /> <br />2 ASPHALT SHINGLES SHALL BE USED ONLY ON ROOF SLOPES OF <br />2:12 OR GREATER, FOR ROOF SLOPES FROM 212 UP TO 4:12 <br />DOUBLE UNDERLAYMENT APPLICATION IS REQUIRED, <br /> <br />3, UNLESS OTHER'WISE NOTED, REQUIRED UNDERLAYMENT SHALL <br />CONFORM 'WITH ASTM D 226, TYPE 1, OR ASTM 4869, TYPE 1 <br />FBC 1507,],3 <br /> <br />4. SELF ADHERING BITUMEN SHEET SHALL COMPLY 'WITH ASTM D225 <br />DR ASTM D3462, <br />FBC 150734 <br /> <br />5. ASPHALT SHINGLES SHALL HAVE SELF SEAL STRIPS DR BE INTERLOCKING, <br />AND COMPLY 'WITH ASTM D225 OR ASTM D3462. <br />FBC 150735 <br /> <br />6, <br /> <br />FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED, STAINLESS <br />STEEL, ALUMINUM, OR COPPER ROOFING NAILS MINIMUM 12 GA (0105 INCH <br />SHANK 'WITH A MINIMUM 3/8' DIAMETER HEAD, OF A LENGTH TO PENETRATE <br />THROUGH THE ROOFING MATERIALS AND A MINIMuM OF 3/4' <19MM) INTO THE <br />ROOF SHEATHING. 'WHERE THE ROOF SHEATHING IS LESS THAN 3/4' THICK THE <br />PENETRATE THROUGH THE SHEATHING <br />FBC 150736 <br /> <br />NAILS SHALL <br /> <br />7. ASPHALT SHINGLES SHALL BE SECURED TO THE ROOF 'WITH NOT LESS FOUR <br />FASTENERS PER STRIP OR T'WO FASTENERS PER INDIVIDUAL SHINGLE, UNLESS <br />OTHER'WISE NOTED ATTACHMENT OF ASPHALT SHINGLES SHALL CONFORM 'WITH <br />ASTM D3161 (MODIFIED TO 110 MPH) DR M- DC PA 107-95. <br />FBC 1507.37 <br />