My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
07-6451
Zephyrhills
>
Building Department
>
Permits
>
2007
>
07-6451
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:36:23 PM
Creation date
6/22/2007 2:57:28 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
07-6451
Building Department - Name
CERVALLOS,JUAN
Address
6215 ABBOTT STATION DR 107-108
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />May. 23. 2007 12:06PM <br /> <br />/ I <br />SIGNATURES PROPI::RTY OWN . <br />(SIGNEDBY) /~rf~ <br /> <br />SPRINKLER OR - <br />(SIGNED BY) ~~. 'CJ.M <br /> <br />ADDITIONAL EXPLANATION AND NOTES: <br />IFP ProjGCl #12C07020 <br /> <br />N/A <br />PRESSURE <br />ReOUCING <br />VALVE TEST <br /> <br />TEST <br />DESCRIPTION <br /> <br />TESTS <br /> <br />BLANK <br />TI::STING <br />GASKETS <br /> <br />WELDING <br /> <br />CUTOUTS <br />(DISCS) <br />HYURAUlIC DATA <br />NAMEPLATE <br />REMARKS <br /> <br />INTERNATIONAL FIRE PROTECTION <br /> <br />No. 0341 <br /> <br />P. 3 <br /> <br />International Fire Protection, Inc. <br />1402 Mercantile Court <br />Plant City, FL 33563 <br /> <br />MAKE & Sr::ll,...ul <br />MODEL <br /> <br />:s I A II~ PRe~~URE <br /> <br />FLOW RA I t: <br /> <br />(FLOWING) <br /> <br />INLt: I (t'~I) I UU I Lt:T (P~I) INLET (PSI)! oUTLt: I . <br /> <br />I I <br />.HYDRO~ 'A Lj:, HyarostatlC lests shall be make at not less lnan LUU pSI (13.6 Dars) for 2 hours or 50 pSI (3.4 Dars) <br />above static pressure in excess of 150 psi (102 bars) far 2 hours. Differential dry-pipe valve clappers shall be left <br />open during the lest to prevent damage. All aboveground piping leakage shall be stopped. <br /> <br />PNEUMATIC: Establish 40 psi (2.7 bars) air pressure and measure drop. which shall not exceed 11/2 psi (0.1 bars) <br />in 24 hours. Test pressure tanks at nonnal water level and air pressure and measure air pressure drop, which shall <br />not exceed 11/2 psi (0,1 bars) in 24 hours. <br /> <br />All piping hydrostatically tested at Dsi oveL!tliltic for hrs, <br />Dry piping pneumatically tested DYES DNO <br /> <br />Equipment operates properly []]YES DNO <br /> <br />Do you certify as the Sprinkler Contractor that additives and corrosive chemicals. <br />sodium silicate or derivatives of sodium silicat., brine, or other corrosive chemicals <br />were not used for testing systems or stopping leaks? [!]YES DNO <br /> <br />DRAIN I Reading of gaug.'ocated near water I Residual pressure with valve in test <br />TEST I supply test connection: _ psi ~bars) lconnection open wide: _ psi ~ bars) <br /> <br />Underground mains and lead in connections to system risers flushed before OTHER - EXPLAIN <br />connection made to sprinkler piping. <br />Verified by copy ofthe U form no. 85B <br />Flushed by installer of underground <br />sprinkler piping <br /> <br />If powder driven fasteners are used in <br />concrete, has representative sample DYES <br />testing been satisfactorily completed'? <br /> <br />NUMBER USED <br /> <br />M) <br /> <br />IF NO, STATE REASON <br /> <br />DYES <br />DYES <br /> <br />DNO <br /> <br />DNO <br /> <br />DNO <br /> <br />IF NO, 8CPLAIN <br /> <br />LOCATIONS <br /> <br />NUMBER REMOVED <br /> <br />WELDED PIPING <br /> <br />DYI::S <br /> <br />DNO <br /> <br />IF YES <br /> <br />Do you certiry as the Sprinkler Contractor that welding procedures comply <br />with the requiremenlS or at least AWS 010.9. level AR-3 ? <br /> <br />Do you certify that the welding was performed by welders qualified in <br />compliance with the requirements of at least AWS 010.9, level AR-3 ., <br /> <br />Do you certify that welding was carried out in compliance with a documented <br />quality control procedure to insure that all discs are retrieved, that openings <br />in piping are smooth, that slag and other welding residue are removed, <br />and that the internal diameters of piping are not penetrated? <br /> <br />Do you certify that you have a control reature to ensure that all <br />cutouts (discs) are retrieved? <br /> <br />DYI::S <br />DYES <br /> <br />DNO <br />DNO <br /> <br />DYES <br /> <br />DNO <br /> <br />DYES DNO <br />IF NO. EXPLAIN <br /> <br />NAMEPLATE PROVIDI::D <br />YES <br /> <br />DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN <br /> <br />NAME OF SPRINKLER CONTRACTOR <br />INTERNATIONAL FIRE PROTECTION. INC. <br /> <br />., <br /> <br />TESTS WITNESSED BY <br />. vVI~ST_ SUPT. OR PROJECT MJR. <br /> <br />A <br /> <br />,- TITL.1.. .Q. II DA IFf I <br />)...'/v lS/, /d? <br />TITLE DATE/ , <br />FOReMAN 3/ ( 1~7 <br /> <br />.ktl};O <br />
The URL can be used to link to this page
Your browser does not support the video tag.