<br />APPENDIX 13-D <br /> <br />Climate Zones 4, 5, 6 <br />TABLE 6C-1' PRESCRIPTIVE REQUIREMENTS FQR SMALL ADDITIDNS (600 Sq. Fl. and Less), RENDVATIDNS TD EXISTNG BUILDINGS AND SITE-INSTALLED CDMPDNENTS DF MANUFACTURED HDMES <br /> <br /> EQUIPMENT MINIMUM INSTALLED <br /> EFFICIENCY EFFICIENCY <br />(!) Central AlC -Split SEER ~ 13.0' SEER ~ <br />z <br />::::; - Single Pkg. SEER ~ 13.0' SEER ~ <br />0 <br />0 Room unit or PT AC EER ~ 8S EER - <br />u <br /> Electric Resistance ANY <br />(!) Heat pump - Split HSPF ~ 7.7' HSPF - <br />z - Single Pkg. HSPF ~ 7.7" HSPF ~ <br />~ <br />w Room unit or PTHP COP ~2.7' HSPF/COP ~_ <br />:z: <br />w Gas, natural or propane AFUE ~ .78 AFUE ~ <br />u <br />~ Fuel Oil AFUE ~ .78 AFUE ~ <br />Ul <br />a: Electric Resistance EF ~ .92 EF~ <br />b~ Gas; natural or LP-gas EF ~ ,59 EF~ <br />:z:~ FualOil EF ~ .54 EF~ <br /> <br />It <br /> <br /> MINIMUM INSULATION <br /> COMPONENT INSULATION INSTALLED <br /> Concrete Block R-5 lot-II <br />j Frame, 2' x 4' R-11 <br />Frame, 2' x 4' R-19 <br />~ Common, Frame R-11 <br /> Common, Masonry R-3 <br /> Under Attic R-30 <br />Ul Single Assembly; Enclosed <br />(!) R-19 <br />z Frame ~-f~ <br />::::; Melel Pans R-13 <br />W <br />u Single Assembly; Open R-10 <br /> Common, Frame R-11 <br />Ul Slab-on-grade No Minimum -er- <br />a: R-11 <br />0 Raised Wood <br />9 Raised Concrete R-5 <br />"- Common, Frame R-11 <br />t In unconditioned space R-8 /" .--- <br />::l In conditioned space No minimum <br />Cl <br /> <br />It <br /> <br />TABLE 6C-2' PRESCRIPTIVE REQUIREMENTS FDR GLASS AREAS IN ADDITIONS ONLY <br /> <br />. See Tabie 13-607.1.ABC.3.2 and 13-608.1.ABC.3,2 <br /> <br />Maximum percenlege glass to floor area allowed Is selected by type, overhang length, and solar heat gain coefficient. Maximum % ~ Installed % ~ ~ <br />GLASS TYPE, OVERHANG, AND SOLAR HEAT GAIN COEFFICIENT REQUIRED FOR GLASS PERCENTAGE ALLOWED <br />UP TO 20% UP TO 30% UP TO 40% CUP TO 50o/~ <br />Single Double Single Double Single Double (SInQle) Double <br />OH-SHGC OH-SHGC OH-SHGC OH-SHGC OH-SHGC OH-SHGC OH-SHGC OH-SHGC <br />1'-.87 0'- .78 2'-.87 1'- .78 3' - ,87 2' -.78 4' - ,87 3' -.78 <br />0'-.75 l' - ,75 0' - .61 2' - .75 l' - ,61 3' - .75 2' - .61 <br /> 0' - ,57 l' - .57 0' -.44 2' - ,57 1'- .44 <br /> 0' - ,39 @V 0'- .35 <br /> 0'- .30 <br />Get certified SHGC from the manufacturer or use defaults: Single ciear SHGC ~ .75, doubie clear SHGC ~ .66, and single tint SHGC ~ .64 <br />TABLE 60-3 MINIMUM REQUIREMENTS FOR All PACKAGES <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />exterior Joints 8< Cracks 606,1 To be caulked, gasketed, weather-stripped or otherwise sealed. t/ <br />Exterior Windows 8< Doors 606.1 Max. 0.3 cfmlsq,fl. window area; .5 clmlsq.fl. door area. V- <br />Sole 8< Top Plates 606.1 Sole plates and penetrations through top plates of exterior walls must be sealed. V <br />Reeessed Ughting 606.1 Type IC rated with no penetrations (two altematives allowed). - <br />Multistory Houses 606.1 Air barrier on perimater 01 fioor cavity between floors, - <br />Exhaust Fans 606.1 Exhaust fans vented to unconditioned space shall have dampers, except for combustion devices with Integral exhaust - <br /> ductwork. <br />Combustion Heating 606.1 Combustion space and water heating systems must be provided with outside combustion air, except for direct vent - <br /> appliances. <br />Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked circuit breaker electric or cutoff ~ <br /> (gas) must be provided. External or built-in heat trap required for vertical pipe risers. <br />SWimming Pools 8< Spas 612.1 Spas & heated pools must have covers (except solar heated). Noncommercial pools must have a pump timer. Gas spa & - <br /> pool heaters must have minimum thermal efficiency of 78%. <br />Hot Water Pipes 612.1 Insulation is required for hot water circulating systems (including heat recovery units). -- <br />Shower Heads 612.1 Waler flow must be restricted to no more than 2.5 gaHons per minute at 80 psig. ~ <br />HV AC Duct Construction, 610.1 AH ducts, fittings, mechanical equipment and plenum chambers shaH be mechanicaHy attached, sealed, insulated and - <br />Insulation 8< Installation InstaHed in accordance with the critaria of Section 610.1. Ducts in attics must be insulatad to a minimum of R-6. <br />HV AC Controls 607.1 Separate readily accesslbla manual or automatic thermostat for each system. - <br /> <br />GENERAL DIRECTIONS: <br />1. On Table 6C-1 indicate the R-value of the insulation being added to each component and the efficiency levels of 1he equipment being installed, All R-values and efficiencies Installed must meet or exceed <br />the minimum values listed. Components and equipment ne~her being added nor renovated may be lell blank, <br />2, ADDITIONS ONLY. Determine the pen:entage of new glass to cond~ioned floor area in the addition as foHows. Total the areas of aH glass windows, sliding glass doors and glass door panels, Double the <br />area 01 all nonvertical roof glass and add ~ to the previous total. When glass In existing exterior waHs is being removed or enclosed by the addition, an amount equal 10 the total area of this glass may be <br />subtracted from the total glass area. Divide the adjusted glass area total by tho cond~ioned Iloor area of the addition, Multiply by 100 to get the pe~ent. Rnd the largest glass pen:entage under which your <br />calculated pen:entage laHs on Table 6C-2. Prescrlptlves are given by the type of glass (singie or double pane) and the overhang (DH) paired wflh a solar heat gain coefficient f;HGC). For a given glass type <br />and overhang, the minimum solar heat gain coefficient allowed is spec~led. Actual glass windows and doors previously in the exterior waHs o!lhe housend being relnstaHed 1n the addition do not have 10 <br />comply with the overhang and solar heat gain coefficient requirements on Table 6C-2. All new glass In the add~ion must meet the requirement for one of the options in the glass peltentage category you <br />Indicated. The overhang (OH) distance Is measured perpendlculariy lrom the face of the glass to a point directly under the outermost edge of the overhang. <br />3. RENOVATIONS ONLY. Replacement glass needs to meet the folloWing requirements. Any glass type and solar heat gain coefficient may be used for glass areas which are under at least a 2~foot overhang <br />and whose lowest edge does not extend further than 8 feet from the overhang. Glass areas being renovated that do not meet this criteria must be either single-pane tinted, double-pane clear or double-pane <br />tinted. <br />4. BUILDING SYSTEMS. Comply when new system is installe<! for system Installed. <br />5. Complete the information requested on the top half of page 1 <br />6 Read 'Mlnlmum Requirements for Small Add~lons and Renovations: Table 6C-3. and check all applicable items. <br />7. Read, sign and date the 'Owner/Agent" certification statement on page 1. <br /> <br />13-D.36R <br /> <br />FLORIDA BUILDING CODE - BUILDING <br /> <br />.._-,--------"_..__...~"."--_.,,-- <br />