Laserfiche WebLink
<br />Zephyrhills Fire Rescue <br />6907 Dairy Road, ZephyrhilIs, FL 33542 <br /> <br />Fire Marshal <br />Kerry Barnett <br /> <br />Bus (813) 780-0041 <br />Fax (813) 780-0044 <br /> <br />March 26, 2007 <br /> <br />Plan Review Comments <br /> <br />I have reviewed the plans for the "Shirts and Caps Addition" located at 38530 5th Ave <br />and my comments have been placed below. Please contact me if there are any questions <br />with regards to my comments. <br /> <br />1. Building shall comply with the applicable codes of the Florida Fire Prevention <br />Code 2003 edition. <br />2. Page A-I: All secondary exits shall have panic hardware. This would include the <br />rear door and break room door. <br />3. Page A-I: Opening into existing building shall have fire rated doors to match the <br />integrity of the rated wall. Doors shall also have magnetic releases tied to the fire <br />alarm. <br />4. Page E-l: Exit lighting shall have battery backup. Emergency lighting and exit <br />lighting shall be on a separate breaker. <br />5. Page E-3: If doors are being installed going from the future office area into the <br />show room, install a combo exit emergency light above the door. <br />6. Page E-3: Install additional emergency light in future office area across the room <br />from other emergency light. (if a combo is not installed above door) <br />7. Page E-3: Install emergency lighting in restrooms. <br />8. Page E-4: Fire extinguisher not needed where the doors are located to enter into <br />existing building. <br />9. Page M-3: Furnish duct detectors due to fire alarm system being installed in new <br />addition. <br />10. Submit plans on fire alarm system for approval and permit. <br /> <br />Inspections required: <br /> <br />1. A building final shall be conducted. <br /> <br />Separate comments will be made on the fire alarm plan once those are submitted. Fees <br />assessed at this time are for plan review only. <br />