<br />ENGINEER1S <br /> <br />NOTES: <br /> <br />PRE-CAST AND PRE-STRESSED CONCRETE COMPONENTS SHALL BE USED AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS, PRE-CAST LINTELS HAVE <br />BEEN REVIEwED AND PLACED BASED ON DESIGN ALLOwABLE LOAD INFORMATION PROVIDED BY SPECIFIED PROVIDER, ENGINEER <br />OF RECORD MUST PROVIDE IN wRITING ANY CHANGE IN LINTEL MANUFACTURER, ALL OTHER STRUCTUAL PRE-CAST COMPONENT <br />MANUFACTURERS MUST SUBMIT DESIGN LOAD INFORMATION TO ENGINEER OF RECORD FOR APPROVAL, ENGINEER OF RECORD RESERVES THE RIGHT <br />TO MAKE ANY CHANGES AFTER SUCH INFORMATION HAS BEEN PROVIDED FOR REVIEw, CONTRACTOR, AS PROJECT COORDINATOR; SHALL BE <br />RESPONSIBLE FOR INSURING INFORMATION REQUESTED ABOVE HAS BEEN SUBMITTED TO ENGINEER OF RECORD IN A TIMEL Y MANNER wHEN AVAILABLE, <br />ALL ROOF CLADDING PRODUCTS ARE THE RESPONSIBILITY OF THE MANUFACTURER. THE ROOF CLADDING MANUFACTURER IS RESPONSIBLE FOR <br />THE VALIDITY OF COMPONENTS PROVIDED, ATTACHMENT INFORMATION GIVEN BY THE MANUFACTURER IS PROVIDED HEREIN, CONTRACTOR1 AS <br />PROJECT CORDINATDR) SHALL BE RESPONSIBLE FOR INSURING THAT THE APPROPRIATE ROOFING MATERIAL IS USED AND THAT IT HAS BEEN <br />INSTALLED PER MANUFACTURER'S SPECIFICATIONS SUCH THAT IT wILL wITHSTAND THE COMPONENTS AND CLADDING PRESSURES REQUIRED BY <br />THE SEALED PLANS, <br />ALL PRE-ENGINEERED wOOD PRODUCTS SHALL BE VERIFIED BY TRUSS MANUFACTUERER. TRUSS MANUFACTURER SHALL HAVE THE AUTHORITY <br />TO MAKE SUBSTITUTIONS FOR PRODUCTS SPECIFIED ON THE PLANS DUE TO AVAILABLITY DR ECONOMICS, CHANGES SPECIFIED BY THE TRUSS <br />MANUFACTURER SHALL CONTROL. CHANGES MADE AFTER TRUSS ENGINEERING HAS BEEN PROVIDED TO ENGINEER OF RECORD) MUST BE <br />APPROVED BY THE ENGINEER OF RECORD, <br />THE ENGINEER HAS NOT REVIEwED THE PRE-ENGINEERED TRUSS MANUFACTURER'S LAYOUT TO DETERMINE ANY LOAD BEARING CONDITIONS <br />AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER TRUSS LOAD INFORMATION IS SUPPLIED TO THE ENGINEER, <br /> <br />ALL wORK TO BE COMPLETED ACCORDING TO THE 2001 EDITION FLORIDA BUILDING CODE <br /> <br />1. <br />2, <br />3, <br />4, <br />5, <br /> <br />6, <br /> <br />'WIND DESIGN SPEED 110 MPH (3 see gust) , <br />THE wIND IMPORT ANCE F ACTOR IS 1.0 FOR RESIDENTIAL HOME <br />THE wIND EXPOSURE FOR BUILDING IS CATEGORY I'B'/ <br />THE APPLICABLE INTERNAL PRESSURE COEFFICIENT = +.18/-.18 <br />THE DESIGN wIND PRESSURE COMPONENTS ~ CLADDING (ROOF) <br />ZONE 1 ZONE 2 <br />@ 10 SQFT +12,5/-19,9 @ <br />@ 20 SQFT +11.4 /-19,4 @ <br />@ 50 SQFT +10,0 /-18,6 @ <br />@ 100 SQFT +10,0 /-18,1 @ <br /> <br />10 SQFT <br />20 SQFT <br />50 SQFT <br />100 SQFT <br /> <br />+12,5/-42.1 <br />+11.4/-38,2 <br />+10,0/-33 <br />+ 10,0/ -29.1 <br /> <br />ALL PRE-ENGINEERED TRUSSES TO BE DESIGNED USING THE MOST RECENT TPI CRITERIA, TRUSSED TO BE HANDLED AND INSTALLED USING MOST RECENT <br />HIB RECOMMENDATIONS, TEMPORARY AND PERMANENT BRACING SHALL BE PER MOST RECENT HIB RECOMMENDATIONS UNLESS NOTED OTHERwISE) OR <br />MORE STINGENT CODE REQUIREMENTS APPL y, TRUSS ENGINEER IS RESPONSIBLE FOR INDICATING ALL TRUSS CONNECTIONS, ALL COMPONENTS TO BE <br />DESIGNED FOR BOTH GRAVITY AND UPLIFT LOAD CASES) INCLUDING BEAM COMPONENTS, <br /> <br />THE DESIGN wIND PRESSURE <br /> <br />ZONE 4 <br /> <br />@ 10 SQFT +21.8 /-23,6 <br />@ 20 SQFT +20,8 /-22,6 <br />@ 50 SQFT +19,5 /-21.3 <br />@ 100 SQFT+18,5/-20,4 <br /> <br />COMPONENTS ~ CLADDING (wALLS) <br />ZONE 5 <br />@ 10 SQFT +21.8 /-29.1 <br />@ 20 SQFT +20,8/-27,2 <br />@ 50 SQFT +19,5/-24,6 <br />@ 100 SQFT+18,5/-22,6 <br /> <br />THE ATTACHMENT OF ASPHAL T SHINGLES ON THIS PRODUCT MUST BE IN COMPLIANCE wITH ASTM D3161 CMODIFIED TO 110MPH) DR M-DC PA 107-95, <br />/' <br />TERMITE PROTECTION: <br /> <br />A wEATHER RESISTANT JOB SITE POSTING BOARD SHALL BE PROVIDED TO RECIEVE DUPLICATE TREATMENT CERTIFICATES AS EACH REQUIRED <br />PROTECTION TREATMENT IS CoMPLETED1 PROVIDING A COpy FOR THE PERSON THE PERMIT IS ISSUED TO AND ANOTHER COpy FOR THE BUILDING <br />PERMIT FILES, IF THE SOIL CHEMICAL BARRIER METHOD FOR TERMITE PREVENTION IS USED1 FINAL EXTERIOR TREATMENT SHALL BE COMPLETED PRIOR <br />TO FINAL BUILDING APPROVAL, CFBC-104.2,6) <br /> <br />THE TREATMENT CERTIFICATION SHALL PROVIDE THE PRODUCT USED) IDENTIFY OF THE APPLICATOR, TIME AND DATE OF THE TREATMENT) SITE <br />LOCATION1 AREA TREATEDI CHEMICAL USED; PERCENT CONCENTRATION AND NUMBER OF GALLONS USED TO ESTABLISH A VERIFIABLE RECORDED OF <br />PROTECTION TREATMENT, A PERMANENT SIGN wHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR RE-INSPECTION AND TREATMENT <br />CONTRACT RENEwAL SHALL BE PROVIDED, THE SIGN SHALL BE POSTED NEAR THE wATER HEATER OR ELECTRICAL PANEL. CFBC-104,2,7) <br /> <br />CONDENSATE AND ROOF DOwNSPOUTS SHALL DISCHARGE AT LEAST 1'0" AwAY FROM BUILDING SIDE wALLS. IRRIGATION/SPRINKLER SYSTEMS INCLUDING <br />ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED wITHIN 1'0' OF THE BUILDING SIDE wALLS. CFBC-1503.4.4) <br /> <br />TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION1 wALL COVERINGS SHALL NOT EXTEND TO wITHIN 6 INCHES OF THE FINAL GRADE, <br />EXCEPTIONS: PAINT DR DECORATIVE CEMENTITIOUS FINISH NOT LESS THAN 5/8H THICK ADHERED DIRECTL Y TO THE FOUNDATION wALL, CFBC-1403,1.6) <br /> <br />INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE, SOIL DISTURBED AFTER INITIAL TREATMENT SHALL BE <br />RETREATED INCLUDING SPACES BOXED AND FORMED, CFBC-1816,1.D <br /> <br />SOIL DISTURBED AFTER INTIAL TREATMENT SHALL BE RE-TREATED INCLUDING SPACES BOXED DR FORMED, (FBC-1816,1.2) <br />BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INST ALL TIoN OF TRAPS) ETC'I SHALL BE MADE wITH PERMANENT MET AL DR PLASTIC FORMS, <br />PERMANENT FORMS ~UST BE OF A SIZE DR DEPTH THAT wILL BE ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL TREATMENT, <br />CFBC-1816,1.3) <br /> <br />MINIMUN 6 MIL VAPOR RETARED MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION, IF RAINFALL OCCURS BEFORE VAPOR RETARDER <br />PLACEMENT) RETREATMENT IS REQUIRED, (FBC-1816.1.4) <br /> <br />CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION wALL MUST NE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT, SOIL TREATMENT MUST BE <br />APPLIED UNDER ALL EXTERIOR CONCRETE DR GRADE wITH 1'0" OF THE STRUCTURE SIDEwALLS, (FBC-1816,1.5) <br /> <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION, ANY <br />SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED) SHALL BE RETREATED, (FBC-1816,1.6) <br /> <br />A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF <br />OCCUPANCY wILL BE ISSUED, THE CERTIFICATE OF COMPLIANCE SHALL STATE: "BUILDING HAS RECIEVED A COMPLETE TREATMENT FOR THE <br />PREVENTION OF SUBTERRANEAN TERMITES, THE TREA TMENT IS IN ACCORDANCE wITH THE RULES AND LAwS OF THE FLORIDA DEPARTMENT OF <br />AGRICUL TURE AND CONSUMER SERVICES,8 <br />CFBC-1816,1.7) <br />TERMITE PROTECTION SHALL BE PROVIDED BY FLOOR FRAMIMG OF NATURALLY DURABLE wOOD PRESERVATIVE TREATED wOOD) SOIL TREATMENT DR <br />OTHER APPROVED METHODS, (FBC 2304,1.2) <br />PROTECTIVE SLEEVES AROUND METALLIC PIPING PENETRATING CONCRETE SLABS ON GRADE FLOORS SHALL NOT BE OF CELLULOSE - CoNTAING <br />MATERIALS AND SHALL RECEIVE APPLICATION OF A TERMITICIDE IN ANNULAR SPACE BETwEEN SLEEVE AND PIPE, CFBC-2302,1.3) <br /> <br />AFTER ALL wORK IS COMPLETED, LOOSE wOOD AND FILL MUST BE REMOVED FROM BELOw AND wITHIN 1/0" OF THE BUILDING, THIS INCLUDED ALL <br />GRADE STAKES) TUB TRAP BOXES, FORMS) SHORING OR OTHER CELLULOSE CONTAINING MATERIAL, NO wOOD) VEGATATION; STUMPS) CARDBoARD1 TRASH1 <br />ETC, SHALL BE BURIED wITHIN 15'08 OF ANY BUILDINGOR PROPOSED BUILDING. (FBC-2303,1.4) <br /> <br />GENERAL NOTES: <br /> <br />wINDOw AND DOOR MANUFACTURERS TO PROVIDE CERTIFICATION/RATING THAT THEIR wINDOwS AND DOORS <br />wILL wITHSTAND THE PRESSURE RESULTING FROM THE SPECIFIED DESIGN COMPONENTS AND CLADDING wIND <br />PRESSURE AND PROVIDE INSTALLATION INFORMATION wITH THEIR PRODUCTS, <br /> <br />CONTRACTOR TO INSTALL wINDOwS AND DOORS ACCORDING TO INSTRUCTIONS SUPPLIED BY MFGR AND HAVE <br />MAUFACTURERS SPECIFICATIONS (CUT SHEETS) ON SITE AT THE TIME OF INSPECTION FOR REVIEw BY THE <br />BUILDING INSPECTOR, <br /> <br />ALL HURRICANE CLIPS) STRAPS AND FASTENERS ARE TO BE APPLIED ACCORDING TO THE FASTENERS <br />SCHEDULE AND MANUFACTURERS SPECIFICATIONS, IF DESIRED, EQUAL VENT CONNECTORS MADE BY ANOTHER <br />SUPPLIER MAY BE USED IN PLACE OF THE CONNECTORS SHOwN, <br /> <br />FOUNDATION DESIGN BASIS: ASSUMED CAPACITY OF 2000PSF, CONTRACTOR TO VERIFY THAT SITE <br />CONDITIONS MEET THIS REQUIREMENT, <br /> <br />THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS UPON THE INTERACTION OF VARIOUS <br />CONNECTED COMPONENTS, PROVISE ADEQUATE BRACING; SHORING AND ANY OTHER TEMPORARY SUPPORTS <br />AS REQUIRED TO SAFELY COMPLETE THE wORK, <br /> <br />CAST-IN-PLACE CONCRETE DESIGN AND CONTRUCTION <br /> <br />NORMAL wEIGHT REINFORCED CONCRETE SHALL HAVE <br />FOOTINGS AND SLAB GRADE_______ 2500 PSI <br />MASON TRY CELL FILL------------ 2500 PSI <br />ALL OTHER CONCRETE----------- 2500 PSI <br />REINFORCING STEEL SHALL CONFORM TO ASTM A-165) GRADE <br />LAP SPLICES wHERE REQUIRED SHALL BE A MINIMUM OF 250 <br />30" FOR #6 REBAR AND 35" FOR #7 REBAR <br />wELDED wIRE FABRIC SHALL CONFORM TO ASTM A185, <br />BE AS FOLLOwS, <br /> <br />FOOTINGS__________ 3" <br />COLUMNS___________ 1/2" FOR #5 AND SMALLER, 2" FOR ALL OTHER <br />FLOOR SLAB________ 1 1/20 FROM TOP OF SLAB <br /> <br />SPLICES IN REINFORCING SHALL BE AS FOLLOwS: <br />wELDED wIRE FABRIC_____ 8H <br />REINFORCING STEEL_______ ALL BARS LAP MIN 250 <br /> <br />STANDARD -- AMERICAN CONCRETE INSTITUTE, ACI 318-83 <br />A MINIMUM 28 DAY COMPRESSIVE STRENGTH AS FOLLOwS: <br /> <br />40 MINIMUM, <br />FOR #5 REBAR, <br /> <br />SOIL CONDITIONS: <br /> <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS, ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA <br />SHALL BE COMPACTED SUCH THAT IT CAN ADEQUATEL Y SUPPORT 2000 P,S,F, FOUNDATION LOADING. <br />ALL CONTINUOUS wALL FOOTINGS SLAB ON GRADE AREAS SHALL BE PROOF ROLLED, ALL SOFT SPOTS SHALL BE REMOVED AND REPLACED TO <br />FINISH GRADE wITH APPROVED FILL MATERIAL. FILL MATERIAL SHALL BE PLACED IN 60 LAYERS MAX AND SHALL <br />BE COMPACTED TO A MINIMUM OF 95% OBTAINED BY ASTM D-1557) UNTIL FINAL GRADE IS OBTAINED, <br /> <br />MINIMUM CONCRETE COVER FOR REINFORCING SHALL <br /> <br />PL;\r ;~:) 8'l\r\\-b- ') <br />D;; T E J "" 20 ~ 0 It- - . - . .; :> <br />EU'C~NG DEPT APP""V'" Q/fJi~ <br /> <br />DESIGN NOTES: <br />ALL CONSTRUCTION SHALL BE APPROVED IN ACCORDANCE wITH FLORIDA BUILDING CODE, OSHA1 AISC) A\JS D 1.1 CODES AND ALL <br />APPLICABLE LOCAL REQUIREMENTS, THE STRUCTURE IS DESIGNED TO COMPL Y wITH THE 2001 FLORIDA BUILDING CODE. BUILDING BASE <br />CONNECTIONS SHALL BE PROVIDED AS SHOwN, ALL MATERIALS IDENTIFIED BY MANUFACTURER NAME MAY BE SUBSTITUTED wITH <br />MATERIALS EQUAL OR EXCEEDING ORIGINAL RATINGS, <br /> <br />Office <br />c;opy <br /> <br />Ml'L Y WITH ALL <br />i\LL woRK SHALL co, \ BU1LDI}.:G <br />PRE\' AlLING CODES, FLORID, E A. '\' <br />. TIO~ \L ELEl"TRlC COD 0 <br />CODE.:\A 0,' ,-.--" co- c: r-,'Z;"'\.\w'\C::~ <br />C1T\ OF ZEf\ \'1 no' ----~. ./., <br /> <br />ALL INFORMATION ON THIS PAGE IS INTENDED TO BE CORRECT BUT MISTAKES CAN BE MADE AND IT IS THE RESPONSIBILITY <br />OF THE CONTRACTOR TO VERIFY ALL INFORMATION PRIOR TO CONSTRUC ION, <br /> <br />'"""" <br /> <br />I hereby certify tho t I ho ve reviewed this plC)n C)nd found it to be in <br />cOMplionce with section 1606 of the FloridC) Building Code) 2001 edition) <br /> <br />~ \ ^( <br />~ ?Iv <br />'[ -I <br />\ i) (l- \) <br /> <br />DAVID Cl\I~R <br />DOGWOOD LANE <br />D " 'W " S ~ I rr I-I , P " E " <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />Custom flame Plan Service <br />9909 ~ALLASTON DRIVE-DADE CITY FLORIDA 33525 <br />P\{]N[: 352-52] -0865 r AX' 352-521-0867 [ -MA!L: zephyr27@gt<" net <br /> <br />7 OCT 2004 <br /> <br />RICK GOLLHARDT - DRAFTSMAN <br />iC/ro;(JO'I <br />SHEET OF <br /> <br />ENGINEER NOTES <br />STANDARD NOTES <br /> <br />1 OF 10 <br /> <br />DATE <br /> <br />SCALE <br /> <br />JOB NO <br /> <br />DC) vid W, SMith; P,E, <br /> <br />DESIGN/DRAWN CHECKED <br />R, GOLLHARDT D.W,SMITH'p,E, <br /> <br />2004-34 <br /> <br />ENGINEER LICENCE ~53608 <br />