My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
06-5379
Zephyrhills
>
Building Department
>
Permits
>
2006
>
06-5379
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:22:17 PM
Creation date
10/26/2007 9:08:01 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
06-5379
Building Department - Name
RYMAN,KEVIN
Address
6841 MEDICAL VIEW LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />'! <br /> <br />PRESCRIPTIVE REQUIREMENTS LlST* <br /> <br />* All Basic Prescriptive Requirements, designated in the Code by ".i.ABCD" and <br />summarized on the front of this form, must also be met. <br /> <br />FORM 400C-601 <br />METHOD C <br /> <br />Petache.d Commercial Buildings Less than 200 sq.ft. <br /> <br />Glass Area: <br />Overhang: <br /> <br />Walls: <br /> <br />RoofslCeili gs: <br />Floors: <br />Cooling SYl tem: <br />Heating Sy tem: <br /> <br />No limit. <br />Minimum 1 foot if not under another structure; or <br />No overhang with a glazing Solar Heat Gain Coefficient of 0.48 or less. <br />Minimum insulation level <br />Frame walls - R-11. <br />Masonry walls - R-5. <br />Minimum insulation level- R-19. <br />Minimum insulation level - None. <br />Code minimums as per section 407.1.ABCD.3. <br />Code minimums as per section 408.1.ABCD.3. <br /> <br />Skyboxes or Sports Stadiums <br /> <br />Glass: I <br />Overhang: i <br />Walls: ! <br /> <br />I <br />Roofs/Ceilinds: <br />Floors: 1 <br />I <br /> <br />Cooling syst~m: <br /> <br /> <br />Heating systlm: <br />Air Distributioh: <br /> <br />Ughting: <br /> <br />Glass: <br />Overhang: <br /> <br />I <br />! <br /> <br />ROOfs/ceilingj' <br />Floors: <br />Cooling Syste : <br />Heating Syste : <br />Lighting: <br /> <br />Walls: <br /> <br />CUMATE ZONES , 5 S <br /> <br /> CHECK <br />Table 4C-1 <br /> - <br /> - <br /> - <br /> - <br /> - <br /> - <br /> - <br /> - <br /> - <br />Table 4C-2 <br /> <br />No limit with glazing Solar Heat Gain Coefficient of 0.48 or less. <br />None required. <br />Minimum insulation level <br />Frame walls - R-11. <br />Masonry walls - R-5. <br />Minimum insulation level- R-19. <br />Minimum insulation level <br />Frame f1oor- R-19. <br />Concrete floor - None. <br />Minimum equipment efficiency requiremen~ <br />Air cooled -10.0 EER or 10.5 SEER. t- <br />Water cooled - 11.0 EER. <br />Code minimums as per section 408.1.ABCD.3. <br />A programmable setback shall be installed for in-season use; <br />At least one humidistat control per zone shall be installed for off-season use. <br />EXCEPTION: Installation of a central energy management system. <br />Total connected wattage shall not exceed 1.8 watts per square foot of conditioned space. <br /> <br />General Req irements for Building PaCkages <5,000 sq.ft. <br /> <br />Traffic Safe y Control Towers <br /> <br />No limit <br />Minimum 1 foot if not under another structure; or <br />No overhang with a glazing Solar Heat Gain Coefficient of 0.48 or less. <br />Minimum insulation level <br />Frame walls - R-11. <br />Masonry walls - R-5. <br />Minimum insulation level - R-19. <br />Minimum insulation level- None. <br />Code minimums as per section 407.1.ABCD.3. <br />Code minimums as per section 408.1.ABCD.3. <br />Total connected wattage shall not exceed 2.1 watts per square foot of conditioned space. <br /> <br />lab-on-Grade <br />I taised Wood <br />f aised Concrete <br />~ asonry <br />. ~ ood Frame <br />,., etal Frame <br />. I sulation above Deck <br />II sulation in Attic or Dropped Ceiling Cavity <br />INFILTRATION: <br />DUCTS; <br />DOMESTIC HO <br />LIGHTING CON <br /> <br />R-O <br />R-19 <br />R-7 <br />R-7 (exterior, adjacent and common) <br />R-11 (exterior, adjacent and common) <br />R-13 (exterior, adjacent and common) <br />R-19 <br />R-19 <br />Code minimums in section 406.1.ABCD.1 <br />, Code minimums in section 41 0.1.ABCD.2 <br />WATER: Code minimums in section 412.1.ABCD.3 <br />ROLS: Each space must have the lights divided into at least two "banks" - each one with a manual On/Off switch; <br />OR Each space must have one occupancy sensor (or other automatic control) to turn the lights on and off. <br /> <br />FLOOR: <br /> <br />WALL: <br /> <br />ROOF: <br /> <br />-2- <br /> <br />Table 4C-3 <br /> <br />Table 4C-4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.